USGS ScienceSearch

Geology topics

Research about Aberdeen, South Dakota

Source-linked reports with geographic coverage including Aberdeen, South Dakota.

3 recordsLinked to original sources

Revised groundwater-flow model of the glacial aquifer system north of Aberdeen, South Dakota, through water year 2015

The city of Aberdeen, in northeastern South Dakota, requires an expanded and sustainable supply of water to meet current and future demands. Conceptual and numerical models of the glacial aquifer system in the area north of Aberdeen were developed by the U.S. Geological Survey in cooperation with the City of Aberdeen in 2012. The U.S. Geological Survey, in cooperation with the City of Aberdeen, completed a study to revise the original numerical groundwater-flow model using data through water year (WY) 2015 to aid the City of Aberdeen in their development of plans and strategies for a sustainable water supply and to increase understanding of the glacial aquifer system and groundwater-flow system near Aberdeen. The original model was revised to improve the fit between model-simulated values and observed (measured or estimated) data, provide greater insight into surface-water interactions, and improve the usefulness of the model for water-supply planning. The revised groundwater-flow model (hereafter referred to as the “revised model”) presented in this report supersedes the original model. The purpose of this report is to describe a revised groundwater-flow model including data collection, model calibration, and model results for the glacial aquifer system including the Elm, Middle James, and Deep James aquifers north of Aberdeen, South Dakota, using updated hydrologic data through WY 2015. The original numerical model was revised in several ways. The model was modified by adding four new layers, which included a surficial layer, two intervening confining layers, and a shale bedrock layer. The revised model provides an improved understanding of the groundwater-flow system in comparison to the original model. The principal aquifers of the model area include portions of the Elm, Middle James, and Deep James aquifers. The lithologic information used to define and describe the aquifers in the model area was unaltered; however, aquifer properties and boundary conditions were reviewed and updated using geological information reported by the South Dakota Department of Environmental and Natural Resources and information obtained from geophysical investigations for this study. The horizontal extent of the Elm, Middle James, and Deep James aquifers was unaltered from the original model. The thickness of the Deep James aquifer was modified based on interpretations from the geophysical investigations. In general, groundwater in the Elm aquifer flowed from northwest to southeast and locally towards rivers and streams. Similarly, in the Middle James and Deep James aquifers, groundwater also typically flowed southeast. The revisions made to the original model include use of the following MODFLOW stress packages: Recharge, Evapotranspiration, Time-Variant Specified Head, Wells, Drains, and Stream Flow Routing, all of which were updated from the original model except for the Stream Flow Routing Package, which replaced the River Package used in the original model. Model calibration is the process of estimating model parameters to minimize the differences, or residuals, between observed data and simulated values; therefore, Parameter ESTimation (PEST) software was used to optimize model input parameters by matching model-simulated values to observed data. Calibration parameters included horizontal hydraulic conductivity, vertical hydraulic conductivity, specific yield, specific storage, and vertical streambed conductance for stream and drain cells. Multipliers were used to calibrate the recharge and evapotranspiration stresses. Evapotranspiration extinction depth also was adjusted during model calibration. Comparisons to the original model are described to highlight the changes made in the revised model. In general, the revised model adequately simulates the natural system and compares favorably with observed hydrologic data. Simulated water levels were evaluated by comparing them to single water-level observations at selected well locations. The selected wells were the same wells used in the original model. The coefficient of determination value between simulated and observed water levels for the revised model was 0.89 and included simulated and observed values from October 1, 1974 (WY 1975), through September 30, 2015 (WY 2015). The coefficient of determination value for the original model was 0.94 and included simulated and observed values from October 1, 1974, through September 30, 2009. The difference may indicate that the original model could have been overfit to hydraulic head observations because base flow was not simulated. The additional data used in the revised model included some climatically wetter, more extreme periods, such as 2011, in which annual precipitation was 30.9 inches. Average annual precipitation for the original model timeframe, which included data from WYs 1975–2009, was 20.26 inches. Additional precipitation data for WYs 2010–15, included in the revised model timeframe, resulted in an average annual precipitation for WYs 1975–2015 in the model area of 20.6 inches. The larger variability in climate data coupled with the additional water-level data could explain the lower coefficient of determination for water levels in the revised model. The revised model was used to calculate various groundwater-budget components for steady-state and transient conditions for WYs 1975–2015. The time-variant specified-head cells in the revised model had the largest change when compared to the original steady-state model for inflows and outflows. Comparing the transient budget components between the original and the revised models indicated that inflow from recharge and time-variant specified-head cells had the greatest effect on groundwater inflows, and outflow from storage had the greatest effect on groundwater outflows. The simulated potentiometric contours from the revised model were compared with (1) the observed (interpreted) potentiometric surface (layer 2) and the hydraulic head values (layers 4 and 6) and (2) the simulated contours from the original model. The simulated hydraulic gradients and general direction of groundwater flow in the Elm aquifer in the revised model generally matched the observed potentiometric contours, the simulated potentiometric contours from the original model, and general flow directions interpreted to be perpendicular to the contours. Minor discrepancies between simulated potentiometric contours from the revised model and the observed potentiometric contours may be due to the lack of observed data in the model area. The revised model was designed to reduce the limitations of the original model. The revisions were validated by comparing the results of the original model with the revised model. A primary benefit of the revised model is the inclusion of the surficial deposits and the confining units as explicit layers in the model. The addition of the surficial layer was beneficial for three primary reasons: (1) more accurate representation of recharge from precipitation, (2) more accurate representation of groundwater evapotranspiration, and (3) more accurate representation of groundwater and surface-water interactions. The groundwater model is a numeric approximation of a complex physical hydrologic system, and the revised model data were interpolated in regions with sparse data. Additionally, model discretization included averaged and interpolated values for water use, withdrawal rates, and hydraulic conductivity. The revised model provides a useful estimate for hydraulic gradients, groundwater-flow directions, and aquifer response to groundwater withdrawals.

South Dakota

Conceptual and numerical models of the glacial aquifer system north of Aberdeen, South Dakota

This U.S. Geological Survey report documents a conceptual and numerical model of the glacial aquifer system north of Aberdeen, South Dakota, that can be used to evaluate and manage the city of Aberdeen's water resources. The glacial aquifer system in the model area includes the Elm, Middle James, and Deep James aquifers, with intervening confining units composed of glacial till. The Elm aquifer ranged in thickness from less than 1 to about 95 feet (ft), with an average thickness of about 24 ft; the Middle James aquifer ranged in thickness from less than 1 to 91 ft, with an average thickness of 13 ft; and the Deep James aquifer ranged in thickness from less than 1 to 165 ft, with an average thickness of 23 ft. The confining units between the aquifers consisted of glacial till and ranged in thickness from 0 to 280 ft. The general direction of groundwater flow in the Elm aquifer in the model area was from northwest to southeast following the topography. Groundwater flow in the Middle James aquifer was to the southeast. Sparse data indicated a fairly flat potentiometric surface for the Deep James aquifer. Horizontal hydraulic conductivity for the Elm aquifer determined from aquifer tests ranged from 97 to 418 feet per day (ft/d), and a confined storage coefficient was determined to be 2.4x10 -5 . Estimates of the vertical hydraulic conductivity of the sediments separating the Elm River from the Elm aquifer, determined from the analysis of temperature gradients, ranged from 0.14 to 2.48 ft/d. Average annual precipitation in the model area was 19.6 inches per year (in/yr), and agriculture was the primary land use. Recharge to the Elm aquifer was by infiltration of precipitation through overlying outwash, lake sediments, and glacial till. The annual recharge for the model area, calculated by using a soil-water-balance method for water year (WY) 1975-2009, ranged from 0.028 inch in WY 1980 to 4.52 inches in WY 1986, with a mean of 1.56 inches. The annual potential evapotranspiration, calculated in soil-water-balance analysis, ranged from 21.8 inches in WY 1983 to 27.0 inches in WY 1985, with a mean of 24.6 inches. Water use from the glacial aquifer system primarily was from the Elm aquifer for irrigation, municipal, and suburban water supplies, and the annual rate ranged from 1.0 to 2.4 cubic feet per second (ft 3 /s). The MODFLOW-2005 numerical model represented the Elm aquifer, the Middle James aquifer, and the Deep James aquifer with model layers 1-3 respectively separated by confining layers 1-2 respectively. Groundwater flow was simulated with 75 stress periods beginning October 1, 1974, and ending September 30, 2009. Model grid spacing was 200 by 200 ft and boundaries were represented by specified-head boundaries and no-flow boundaries. The model used parameter estimation that focused on minimizing the difference between 954 observed and simulated hydraulic heads for 135 wells. Calibrated mean horizontal hydraulic conductivity values for model layers 1-3 were 94, 41, and 30 ft/d respectively. Vertical hydraulic conductivity values for confining layers 1 and 2 were 0.0002 and 0.0003 ft/d, respectively. Calibrated specific yield for model layer 1was 0.1 and specific storage ranged from 0.0003 to 0.0005 per foot. Calibrated mean recharge rates ranged from 2.5 in/yr where glacial till thickness was less than 10 ft to 0.8 in/yr where glacial till thickness was greater than 30 ft. Calibrated mean annual evapotranspiration rate was 8.8 in/yr. Simulated net streamflow gain from model layer 1 was 3.1 ft 3 /s.

South Dakota

Aquifer test to determine hydraulic properties of the Elm aquifer near Aberdeen, South Dakota

The Elm aquifer, which consists of sandy and gravelly glacial-outwash deposits, is present in several counties in northeastern South Dakota. An aquifer test was conducted northeast of Aberdeen during the fall of 1999 to determine the hydraulic properties of the Elm aquifer in that area. An improved understanding of the properties of the aquifer will be useful in the possible development of the aquifer as a water resource. Historical water-level data indicate that the saturated thickness of the Elm aquifer can change considerably over time. From September 1977 through November 1985, water levels at three wells completed in the Elm aquifer near the aquifer test site varied by 5.1 ft, 9.50 ft, and 11.1 ft. From June 1982 through October 1999, water levels at five wells completed in the Elm aquifer near the aquifer test site varied by 8.7 ft, 11.4 ft, 13.2 ft, 13.8 ft, and 19.7 ft. The water levels during the fall of 1999 were among the highest on record, so the aquifer test was affected by portions of the aquifer being saturated that might not be saturated during drier times. The aquifer test was conducted using five existing wells that had been installed prior to this study. Well A, the pumped well, has an operating irrigation pump and is centrally located among the wells. Wells B, C, D, and E are about 70 ft, 1,390 ft, 2,200 ft, and 3,100 ft, respectively, in different directions from Well A. Using vented pressure transducers and programmable data loggers, water-level data were collected at the five wells prior to, during, and after the pumping, which started on November 19, 1999, and continued a little over 72 hours. Based on available drilling logs, the Elm aquifer near the test area was assumed to be unconfined. The Neuman (1974) method theoretical response curves that most closely match the observed water-level changes at Wells A and B were calculated using software (AQTESOLV for Windows Version 2.13-Professional) developed by Glenn M. Duffield of HydroSOLVE, Inc. These best fit theoretical response curves are based on a transmissivity of 24,000 ft 2 /d or a hydraulic conductivity of about 600 ft/d, a storage coefficient of 0.05, a specific yield of 0.42, and vertical hydraulic conductivity equal to horizontal hydraulic conductivity. The theoretical type curves match the observed data fairly closely at Wells A and B until about 2,500 minutes and 1,000 minutes, respectively, after pumping began. The increasing rate of drawdown after these breaks is an indication that a no-flow boundary (an area with much lower hydraulic conductivity) likely was encountered and that Wells A and B may be completed in a part of the Elm aquifer with limited hydraulic connection to the rest of the aquifer. Additional analysis indicates that if different assumptions regarding the screened interval for Well B and aquifer anisotropy are used, type curves can be calculated that fit the observed data using a lower specific yield that is within the commonly accepted range. When the screened interval for Well B was reduced to 5 ft near the top of the aquifer and horizontal hydraulic conductivity was set to 20 times vertical hydraulic conductivity, the type curves calculated using a specific yield of 0.1 and a transmissivity of 30,200 ft 2 /d also matched the observed data from Wells A and B fairly well. A version of the Theim equilibrium equation was used to calculate the theoretical drawdown in an idealized unconfined aquifer when a perfectly efficient well is being pumped at a constant rate. These calculations were performed for a range of pumping rates, drawdowns at the wells, and distances between wells that might be found in a production well field in the Elm aquifer. Although the aquifer test indicates that hydraulic conductivity near the well may be adequate to support a production well, the comparison of drawdown and recovery curves indicates the possibility that heterogeneities may limit the productive capacity of specific locations in the Elm aquifer during certain times. Additional test hole drilling and geophysical studies could help characterize these heterogeneities in the aquifer.

South Dakota