USGS ScienceSearch

Geology topics

Thomas E. Imbrigiotta

Publications and source records attributed to Thomas E. Imbrigiotta.

29 records · Page 2Linked to original sources

Effects of sample isolation and handling on the recovery of purgeable organic compounds

This report compares the recovery of purgeable organic compounds (POCs) obtained by using a downhole isobaric sampler developed by the U.S. Geological Survey, a helical-rotor submersible pump, and a point source bailer to collect and isolate samples of ground water from three wells in Now York and New Jersey: the samples contained a total of 13 PCX's delectable at concentrations ranging from 0.5 μg/L to about 400 μg/L. This report also compares the effects of sample handling, specifically the differences in PCX concentration recovery when an isobaric sample container is filled at land surface vs. when it is filled downhole. and when samples art taken using a bailer with and without a bottom-emptying device. These case studies are used to quantify the possible effects of different sample-isolation find sample-handling techniques on POC recovery. The relative effectiveness of the three devices varied by site and by compound. Overall, the POC recoveries achieved by using the helical-rotor submersible pump and the downlink isobaric sampler were not significantly different at the 95 percent confidence, level. POC recovery obtained by using the point source bailer was 11 percent lower overall. The downhole isobaric sampler results exhibited smaller coefficients of variation than did the helical-rotor submersible pump or the point-source bailer results. However, the differences between the coefficients of variation of the downhole isobaric sampler and those of the helical-rotor submersible pump were not significant at the 95 percent confidence level. The nonsignificant smaller coefficient of variation of the downhole isobaric sampler apparently resulted from two fewer sample handling steps that exposed the sample water to ambient air. An independent experiment performed with a different downhole sampler at one of the wells used in this investigation produced a similar statistical result. Also, the POC recovery obtained by pouring sample water out the lop of a point source bailer into 40-mL vials was S percent lower than that obtained by filling vials from a bailer with a bottom-emptying device.

Ground Water Monitoring and Remediation

Laboratory comparison of polyethylene and dialysis membrane diffusion samplers

The ability of diffusion samplers constructed from regenerated cellulose dialysis membrane and low density, lay flat polyethylene tubing to collect volatile organic compounds and inorganic ions was compared in a laboratory study. Concentrations of vinyl chloride, cis ‐1, 2‐dichloroethene, bromochloromethane, trichloroethene, bromodichloromethane, and tetrachloroethene collected by both types of diffusion samplers reached equilibrium with the concentrations of these compounds in test solution within three days. Concentrations of bromide and iron collected by the dialysis membrane diffusion samplers reached equilibrium with the concentrations of these compounds in a test solution within three to seven days. No detectable concentrations of bromide or iron were found in polyethylene diffusion samplers even after 21 days. No measurable concentrations of aluminum, arsenic, barium, cadmium, chromium, iron, mercury, manganese, nickel, and lead, or sulfide, were leached out of dialysis membrane samplers over seven days. Compared with using a gas‐tight syringe to sample the diffusion sampler, clipping the bag and pouring the water sample into a sample vial resulted in only a small 6.2% average loss of volatile organic compounds. Dialysis membrane diffusion samplers offer promise for use in sampling ground water for inorganic constituents as well as volatile organic compounds.

Groundwater Monitoring & Remediation

Contamination in fractured-rock aquifers: Research at the former Naval Air Warfare Center, West Trenton, New Jersey

The U.S. Geological Survey and cooperators are studying chlorinated solvents in a fractured sedimentary rock aquifer underlying the former Naval Air Warfare Center (NAWC), West Trenton, New Jersey. Fractured-rock aquifers are common in many parts of the United States and are highly susceptible to contamination, particularly at industrial sites. Compared to 'unconsolidated' aquifers, there can be much more uncertainty about the direction and rate of contaminant migration and about the processes and factors that control chemical and microbial transformations of contaminants. Research at the NAWC is improving understanding of the transport and fate of chlorinated solvents in fractured-rock aquifers and will compare the effectiveness of different strategies for contaminant remediation.

New Jersey

Demonstration and validation of a regenerated cellulose dialysis membrane diffusion sampler for monitoring ground-water quality and remediation progress at DoD sites (ER-0313)

This final technical report documents the demonstration and validation of regenerated cellulose dialysis membrane diffusion samplers for use in collecting ground water samples for a range of inorganic and organic water-quality parameters. This project, ER-0313, was funded by the Environmental Security Technology Certification Program (ESTCP). The primary objectives of the project were; (1) to determine the usefulness of dialysis samplers in collecting a range of organic and inorganic water quality constituents from ground water, (2) to determine the optimum equilibration times for these constituents to diffuse into the dialysis sampler, (3) to compare water quality results and sampling costs from samples collected with dialysis samplers to samples collected with a low-flow purging technique and polyethylene diffusion bag (PDB) samplers, and (4) to transfer the technology while gaining regulatory acceptance. Field comparisons were conducted at three Department of Defense (DoD) sites: (1) Naval Air Engineering Station (NAES) Lakehurst, NJ, (2) Naval Base Ventura County (NBVC), Port Hueneme and Pt. Mugu, CA, and (3) Naval Air Warfare Center (NAWC) West Trenton, NJ. Dialysis samplers were found to cost significantly less than samples collected with a low-flow purging procedure. Field sampling time was reduced by a factor of more than six times, compared to low-flow purging. The total sampling costs per sample was estimated to be three times less, compared to low-flow purging.

Technical Report

Hydraulic and solute-transport properties and simulated advective transport of contaminated ground water in a fractured-rock aquifer at the Naval Air Warfare Center, West Trenton, New Jersey, 2003

Volatile organic compounds, predominantly trichloroethylene and its degradation products, have been detected in ground water at the Naval Air Warfare Center (NAWC), West Trenton, New Jersey. An air-stripping pump-and-treat system has been in operation at the NAWC since 1998. An existing ground-water-flow model was used to evaluate the effect of a change in the configuration of the network of recovery wells in the pump-and-treat system on flow paths of contaminated ground water. The NAWC is underlain by a fractured-rock aquifer composed of dipping layers of sedimentary rocks of the Lockatong and Stockton Formations. Hydraulic and solute-transport properties of the part of the aquifer composed of the Lockatong Formation were measured using aquifer tests and tracer tests. The heterogeneity of the rocks causes a wide range of values of each parameter measured. Transmissivity ranges from 95 to 1,300 feet squared per day; the storage coefficient ranges from 9 x 10-5 to 5 x 10-3; and the effective porosity ranges from 0.0003 to 0.002. The average linear velocity of contaminated ground water was determined for ambient conditions (when no wells at the site are pumped) using an existing ground-water-flow model, particle-tracking techniques, and the porosity values determined in this study. The average linear velocity of flow paths beginning at each contaminated well and ending at the streams where the flow paths terminate ranges from 0.08 to 130 feet per day. As a result of a change in the pump-and-treat system (adding a 165-foot-deep well pumped at 5 gallons per minute and reducing the pumping rate at a nearby 41-foot-deep well by the same amount), water in the vicinity of three 100- to 165-foot-deep wells flows to the deep well rather than the shallower well.

New Jersey