Study design and analytical results used to evaluate stability of volatile organic compounds in water matrices
Explore the source record for details and available documents.
Geology topics
Publications and source records attributed to Sonja R. Abney.
Explore the source record for details and available documents.
This Fact Sheet presents data for analysis of nanogram-per-liter concentrations of methyl tert-butyl ether (MTBE) and three other ether gasoline oxygenates, including methyl tert-pentyl ether (TAME), diisopropyl ether (DIPE), and ethyl tert-butyl ether (ETBE), by purge- and-trap capillary-column gas chromatography. Long-term method detection levels (LT-MDLs) for MTBE, TAME, DIPE, and ETBE ranged from 15 to 83 nanograms per liter (0.015 to 0.083 microgram per liter). Nanogram-per-liter-concentration detections are reported if all of the identification criteria are met, whereas previous methods censored detections at a pre-determined method reporting level. The reporting level for this method is defined as two times the LT-MDL, does not censor detections at less than this concentration, and is referred to as the nondetection value (NDV). Bias and variability data from multiple analyses, analysts, and instruments over a 60-day period show the oxygenate recoveries ranging from 100 to 109 percent, with 6 to 8 percent relative standard deviation. MTBE, TAME, DIPE, and ETBE were not detected in the analysis of 225 laboratory reagent blanks from January to December 1997. A preservation study in ground water and surface water indicates that all the oxygenates are stable at pH 2 for up to 216 days, with recoveries ranging from 94 to 115 percent on day 216, and relative standard deviations ranging from 5 to 9 percent for the duration of the study.
This report presents precision and accuracy data for volatile organic compounds (VOCs) in the nanogram-per-liter range, including aromatic hydrocarbons, reformulated fuel components, and halogenated hydrocarbons using purge and trap capillary-column gas chromatography/mass spectrometry. One-hundred-four VOCs were initially tested. Of these, 86 are suitable for determination by this method. Selected data are provided for the 18 VOCs that were not included. This method also allows for the reporting of semiquantitative results for tentatively identified VOCs not included in the list of method compounds. Method detection limits, method performance data, preservation study results, and blank results are presented. The authors describe a procedure for reporting low-concentration detections at less than the reporting limit. The nondetection value (NDV) is introduced as a statistically defined reporting limit designed to limit false positives and false negatives to less than 1 percent. Nondetections of method compounds are reported as ?less than NDV.? Positive detections measured at less than NDV are reported as estimated concentrations to alert the data user to decreased confidence in accurate quantitation. Instructions are provided for analysts to report data at less than the reporting limits. This method can support the use of either method reporting limits that censor detections at lower concentrations or the use of NDVs as reporting limits. The data-reporting strategy for providing analytical results at less than the reporting limit is a result of the increased need to identify the presence or absence of environmental contaminants in water samples at increasingly lower concentrations. Long-term method detection limits (LTMDLs) for 86 selected compounds range from 0.013 to 2.452 micrograms per liter (?g/L) and differ from standard method detection limits (MDLs) in that the LTMDLs include the long-term variance of multiple instruments, multiple operators, and multiple calibrations over a longer time. For these reasons, LTMDLs are expected to be slightly higher than standard MDLs. Recoveries for all of the VOCs tested ranged from 36 (tert-butyl formate) to 155 percent (pentachlorobenzene). The majority of the compounds ranged from 85 to 115 percent recovery and had less than 5 percent relative standard deviation for concentrations spiked between 1 to 500 ?g/L in volatile blank-, surface-, and ground-water samples. Recoveries of 60 set spikes at low concentrations ranged from 70 to 114 percent (1,2,3- trimethylbenzene and acetone). Recovery data were collected over 6 months with multiple instruments, operators, and calibrations. In this method, volatile organic compounds are extracted from a water sample by actively purging with helium. The VOCs are collected onto a sorbent trap, thermally desorbed, separated by a Megabore gas chromatographic capillary column, and finally determined by a full-scan quadrupole mass spectrometer. Compound identification is confirmed by the gas chromatographic retention time and by the resultant mass spectrum, typically identified by three unique ions. An unknown compound detected in a sample can be tentatively identified by comparing the unknown mass spectrum to reference spectra in the mass-spectra computer-data system library compiled by the National Institute of Standards and Technology.