Stability of inorganic and methylated arsenic species in laboratory standards, surface water and groundwater under three different preservation regimes

Geogenic arsenic (As) adversely affects drinking water quality in geologically diverse aquifers across the globe. Although the species of As significantly affects its fate, transport, toxicity, and As treatment technology efficacy, reported effectiveness of As species preservation methods varies widely with preservation methods and natural water geochemistry. Our study 1) evaluates the shelf life of As(III), As(V), dimethylarsinate (DMA), and monomethylarsonate (MMA) in standards prepared with ultrapure water; 2) establishes a hold time for these As species in low-iron (Fe) groundwater and surface water samples preserved with a concentration of EDTA that exceeded the sum of the molar concentrations of Al, Fe, Mn, Ca, Mg, and Sr (molar excess of EDTA); and 3) evaluates As(III) species stability in groundwater samples with detectable SO 4 and up to 6.5 mg/L Fe concentrations preserved in 3 ways: less than molar excess EDTA, molar excess EDTA, and Vacuette® tubes with an unknown (proprietary) amount of EDTA. Arsenic species standards prepared with 2.5 mM EDTA in ultrapure water and stored at 4 °C had a shelf life of at least 180 days. As(III) was stable for at least 15 days and DMA and MMA were stable for at least 90 days in environmental samples with Fe less than 1 mg/L that were preserved with a molar excess of EDTA and stored in opaque containers at 4 °C. As(III) species were not stable for any holding time in samples with Fe greater than 1 mg/L and detectable SO 4 when preserved with a molar excess of EDTA and stored in white high density polyethylene bottles at room temperature, or when preserved by storage in EDTA containing Vacuette® tubes at 4 °C. For geochemical or water quality studies where the distribution of As(III) and As(V) is a critical factor, an understanding of the sample chemistry, rapid As speciation analysis after sample collection, and collecting a field spike with the sample can be helpful for collecting accurate inorganic As species data.

Applied Geochemistry

Determination of four arsenic species in environmental water samples by liquid chromatography- inductively coupled plasma - tandem mass spectrometry

Robust and sensitive methods for monitoring inorganic and organic As species As(III), As(V), dimethylarsinate (DMA), and monomethylarsonate (MMA) in environmental water are necessary to understand the toxicity and redox processes of As in a specific environment. The method is sufficiently sensitive and selective to ensure accurate and precise quantitation of As(III), As(V), DMA, and MMA in surface water and groundwater samples with As species concentrations from tens of nanograms per liter to 50 µg/L without dilution of the sample. Mean recoveries of the four species spiked into reagent water, surface water and groundwater and measured periodically over three months ranged from 87.2 % to 108.7 % and relative standard deviation of replicates of all analytes ranged from 1.1 % to 9.0 %. •A PRP-X100 column and nitrate/phosphate mobile phase was used to separate As(III), As(V), DMA, and MMA in 0.45 µm filtered surface water and groundwater matrices. •Oxygen was used in the collision cell of the inductively coupled plasma-mass spectrometer with MS/MS mode to shift the measured As mass from 75 to 91. • The analytical performance of the method and figures of merit including detection limits, precision, accuracy, and interferences when applied to surface water and groundwater matrices were investigated.

MethodsX

Comparison of detection limits estimated using single- and multi-concentration spike-based and blank-based procedures

Spike- and blank-based procedures were applied to estimate the detection limits (DLs) for example analytes from inorganic and organic methods for water samples to compare with the U.S. Environmental Protection Agency's (EPA) Method Detection Limit (MDL) procedures (revisions 1.11 and 2.0). The multi-concentration spike-based procedures ASTM Within-laboratory Critical Level (DQCALC) and EPA's Lowest Concentration Minimum Reporting Level were compared in one application, with DQCALC further applied to many methods. The blank-based DLs, MDL b99 (99th percentile) or MDL bY (= mean blank concentration + s × t ), estimated using large numbers (>100) of blank samples often provide DLs that better approach or achieve the desired ≤1% false positive risk level compared to spike-based DLs. For primarily organic methods that do not provide many uncensored blank results, spike-based DQCALC or MDL rev. 2.0 are needed to simulate the blank distribution and estimate the DL. DQCALC is especially useful for estimating DLs for multi-analyte methods having very different analyte response characteristics. Time series plots of DLs estimated using different procedures reveal that DLs are dependent on the applied procedure, should not be expected to be static over time, and seem best viewed as falling over a range versus being a single value. Use of both blank- and spike-based DL procedures help inform this DL range. Data reporting conventions that censor data at a threshold and report “less than” that threshold concentration as the reporting level have unknown and potentially high false negative risk. The U.S. Geological Survey National Water Quality Laboratory's Laboratory Reporting Level (LRL) convention (applied primarily to organic methods) attempts to simultaneously minimize both the false positive and false negative risk when <LRL is reported and data between DL and the higher LRL are allowed to be reported.

Talanta

Measurement of nutrients in saline and hypersaline waters by discrete analyzer colorimetry without matrix matched calibration standards

Automated, colorimetric analysis of nutrients in samples with high and variable salinity can be time consuming due to the need to matrix match calibration and reference solution matrices with those of samples—particularly when using flow-based analyzers that are prone to detector artifacts caused by optical inhomogeneities, “schlieren”, that form at interfaces between samples and deionized water carrier or wash solutions. Such detector artifacts do not occur in discrete analyzers. Here we report spike recoveries when nitrite, nitrite plus nitrate, ammonia, orthophosphate, and silica were determined in estuarine waters, seawater, and hypersaline surface water samples without calibrator matrix matching using an automated discrete analyzer set up with standard colorimetric methods. Salinities of these samples varied from 0 to 22 percent (%). Spike recoveries and precision were excellent for nitrite and nitrite plus nitrate analyses in samples with salinities up to 15%, for ammonia in samples with salinities up to about 1.7%, and for orthophosphate in samples with salinities up to about 3.5%. Orthophosphate spike recoveries were high biased in hypersaline matrices (salinity >3.5%), likely due to an unidentified sample matrix interference. After applying linear correction factors to account for chemistry-related salt effects, spike recoveries were acceptable for ammonia analyses in samples with salinities in the range of 1.7 to 3.5%, and for silica analyses in samples with salinities in the range of 0 to 3.5%.

Talanta

Aqueous geochemical data from the analysis of stream-water samples collected in June and July 2006 — Taylor Mountains 1:250,000-scale quadrangle, Alaska

We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000-scale quadrangle, Alaska. Parameters for which data are reported include pH, conductivity, water temperature, major cation and anion concentrations, trace-element concentrations, and dissolved organic-carbon concentrations. Samples were collected as part of a multiyear U.S. Geological Survey project entitled ?Geologic and Mineral Deposit Data for Alaskan Economic Development.? Data presented here are from samples collected in June and July 2006. The data are being released at this time with minimal interpretation. This is the third release of aqueous geochemical data from this project; aqueous geochemical data from samples collected in 2004 and 2005 were published previously. The data in this report augment but do not duplicate or supersede the previous data release. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the Taylor Mountains quadrangle is dominated by bicarbonate (HCO3-), although in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry ranges from Ca2+/Mg2+ dominated to a mix of Ca2+/Mg2+/Na++K+. Generally, good agreement was found between the major cations and anions in the duplicate samples. Many trace elements in these samples were at or near the analytical method detection limit, but good agreement was found between duplicate samples for elements with detectable concentrations. All field blank major-ion and trace-element concentrations were below detection.

Alaska

Aqueous geochemical data from the analysis of stream-water samples collected in June and July 2005 — Taylor Mountains 1:250,000 scale quadrangle, Alaska

We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000-scale quadrangle. Parameters for which data are reported include pH, conductivity, water temperature, major cation and anion concentrations, trace-element concentrations, and dissolved organic-carbon concentrations. Samples were collected as part of a multiyear U.S. Geological Survey project "Geologic and Mineral Deposit Data for Alaskan Economic Development." Data presented here are from samples collected in June and July of 2005. The data are being released at this time with minimal interpretation. This is the second release of aqueous geochemical data from this project; 2004 aqueous geochemical data were published previously ( Wang and others, 2006 ). The data in this report augment but do not duplicate or supersede the previous data release. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the Taylor Mountians quadrangle is dominated by bicarbonate (HCO 3- ), though in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO 4 2- ). The major-cation chemistry ranges from Ca 2+ /Mg 2+ dominated to a mix of Ca 2+ /Mg 2+ /Na + +K + . In general, good agreement was found between the major cations and anions in the duplicate samples. Many trace elements in these samples were at or near the analytical method detection limit, but good agreement was found between duplicate samples for elements with detectable concentrations. With the exception of a total mercury concentration of 0.33 ng/L detected in a field blank, field blank major-ion and trace-elements concentrations were below detection.