USGS ScienceSearch

Geology topics

Rene A. Barker

Publications and source records attributed to Rene A. Barker.

6 recordsLinked to original sources

Computer-model analysis of ground-water flow and simulated effects of contaminant remediation at Naval Weapons Industrial Reserve Plant, Dallas, Texas

In June 1993, the Department of the Navy, Southern Division Naval Facilities Engineering Command (SOUTHDIV), began a Resource Conservation and Recovery Act (RCRA) Facility Investigation (RFI) of the Naval Weapons Industrial Reserve Plant (NWIRP) in north-central Texas. The RFI has found trichloroethene, dichloroethene, vinyl chloride, as well as chromium, lead, and other metallic residuum in the shallow alluvial aquifer underlying NWIRP. These findings and the possibility of on-site or off-site migration of contaminants prompted the need for a ground-water-flow model of the NWIRP area. The resulting U.S. Geological Survey (USGS) model: (1) defines aquifer properties, (2) computes water budgets, (3) delineates major flowpaths, and (4) simulates hydrologic effects of remediation activity. In addition to assisting with particle-tracking analyses, the calibrated model could support solute-transport modeling as well as help evaluate the effects of potential corrective action. The USGS model simulates steadystate and transient conditions of ground-water flow within a single model layer. The alluvial aquifer is within fluvial terrace deposits of Pleistocene age, which unconformably overlie the relatively impermeable Eagle Ford Shale of Late Cretaceous age. Over small distances and short periods, finer grained parts of the aquifer are separated hydraulically; however, most of the aquifer is connected circuitously through randomly distributed coarser grained sediments. The top of the underlying Eagle Ford Shale, a regional confining unit, is assumed to be the effective lower limit of ground-water circulation and chemical contamination. The calibrated steady-state model reproduces long-term average water levels within +5.1 or –3.5 feet of those observed; the standard error of the estimate is 1.07 feet with a mean residual of 0.02 foot. Hydraulic conductivity values range from 0.75 to 7.5 feet per day, and average about 4 feet per day. Specific yield values range from 0.005 to 0.15 and average about 0.08. Simulated infiltration rates range from 0 to 2.5 inches per year, depending mostly on local patterns of ground cover. Computer simulation indicates that, as of December 31, 1998, remediation systems at NWIRP were removing 7,375 cubic feet of water per day from the alluvial aquifer, with 3,050 cubic feet per day coming from aquifer storage. The resulting drawdown prevented 1,800 cubic feet per day of ground water from discharging into Cottonwood Bay, as well as inducing another 1,325 cubic feet per day into the aquifer from the bay. An additional 1,200 cubic feet of water per day (compared to pre-remediation conditions) was prevented from discharging into the west lagoon, east lagoon, Mountain Creek Lake, and Mountain Creek swale. Particle-tracking simulations, assuming an aquifer porosity of 0.15, were made to delineate flowpath patterns, or contaminant “capture zones,” resulting from 2.5- and 5-year periods of remediation activity at NWIRP. The resulting flowlines indicate three such zones, or areas from which ground water is simulated to have been removed during July 1996–December 1998, as well as extended areas from which ground water would be removed during the next 2.5 years (January 1999– June 2001). Simulation indicates that, as of December 31, 1998, the recovery trench was intercepting about 827 cubic feet per day of ground water that—without the trench—would have discharged into Cottonwood Bay. During this time, the trench is simulated to have removed about 3,221 cubic feet per day of water from the aquifer, with about 934 cubic feet per day (29 percent) coming from the south (Cottonwood Bay) side of the trench.

Texas

Hydrogeologic framework of the Edwards-Trinity aquifer system, west-central Texas

The Edwards-Trinity aquifer system underlies about 42,000 square miles of west-central Texas, where mostly gently dipping Lower Cretaceous strata comprise three regional aquifers and two regional confining units. The aquifers are the Edwards Aquifer of the Balcones fault zone, the Trinity Aquifer of the Balcones fault zone and Hill County, and the Edwards-Trinity Aquifer of the Edwards Plateau and Trans-Pecos. The Navarro-Del Rio confining unit confines the downdip part of the Edwards Aquifer, and the Hammett confining unit confines the updip, basal part of the Trinity Aquifer and a small southeastern fringe of the Edwards-Trinity Aquifer. Transmissivity averages less than 10,000 feet squared per day throughout more than 90 percent of the study area as the result of widespread cementation and secondary mineral growth. However, in fractured and leached rocks in the Balcones fault zone, transmissivity averages about 750,000 feet squared per day in the Edwards aquifer, which occupies less than 10 percent of the area.

Texas

Historical saturated thickness of the Edwards-Trinity aquifer system and selected contiguous hydraulically connected units, west-central Texas

The Edwards-Trinity Regional Aquifer-System Analysis (RASA) is one of 25 completed or ongoing studies conducted by the U.S. Geological Survey on regional aquifer systems that individually provide essential quantities of ground water to large parts of the country. Underlying about 42,000 mi 2 of west-central Texas, the Edwards-Trinity aquifer system extends approximately from Atascosa County in the southeast to Culberson County in the northwest and from the Rio Grande in the southwest to the Colorado River in the northeast (sheet 2). The Edwards-Trinity aquifer system spans four geographic subareas: Trans-Pecos, Edwards Plateau, Hill Country, and Balcones fault zone (fig. 1). The names of all aquifers in the study area were adopted for RASA purposes directly from nomenclature mandated by the Texas Water Plan (Texas Water Development Board, 1990). The Cretaceous rocks that compose the Edwards-Trinity aquifer system are primarily limestone and dolomite rock, with lesser quantities of terrigenous sand. Although the lithology varies locally and the rocks are not everywhere permeable in all directions, they combine to form a single regional aquifer system. The aquifer system comprises three aquifers and two confining units (figs. 2 and 3). The water-yielding units are the Edwards aquifer of the Balcones fault zone, the Trinity aquifer of the Balcones fault zone and Hill Country, and the Edwards-Trinity aquifer of the Edwards Plateau and Trans-Pecos. The confining units are the Hammett confining unit, which confines basal parts of the Trinity aquifer in the Hill Country and the Edwards-Trinity aquifer in the eastern part of the Edwards Plateau, and the Navarro-Del Rio confining unit, which confines the Edwards and Trinity aquifers along the southeastern margin of the Balcones fault zone. Parts of the aquifer system not overlain by one of these confining units are unconfined, or nearly so. The purposes of this report are to illustrate the historical distribution of saturated thickness (hereafter referred to as the saturated thickness) in the Edwards-Trinity aquifer system, summarize the reasons for the variation in the saturated thickness, and relate the regional effects of this variation to the distribution of transmissivity. The saturated thickness map (sheet 2) was determined for most of the area by subtracting the altitude of the base of the aquifer system (Barker and Ardis, 1992) from the altitude of the historical potentiometric surface (Bush and others, 1993). Where the Edwards and Trinity aquifers are confined in the Balcones fault zone, the saturated thickness is defined by the thickness of the aquifer system, which was determined by subtracting the altitude of the base of the aquifer system from the altitude of the base of the Navarro-Del Rio confining unit (G.E. Groschen and W.G. Stein, U.S. Geological Survey, written commun, 1990).

Texas

Configuration of the base of the Edwards-Trinity aquifer system and hydrogeology of the underlying pre-Cretaceous rocks, west-central Texas

The Edwards-Trinity aquifer system is underlain by an extensive complex of rocks, ranging from Late Cambrian through Late Triassic in age, that are typically about 10 to perhaps 1,000 times less permeable than those composing the aquifer system. The Cretaceous rocks of the aquifer system are separated from the pre-Cretaceous rocks by an unconformity that spans about 60 million years of erosion during the Jurassic Period. The upper surface of the pre-Cretaceous rock complex forms the base of the Edwards-Trinity aquifer system. The configuration of the base reflects the original topography of the eroded pre-Cretaceous land surface plus the effects of subsequent deformation. The most permeable pre-Cretaceous rocks are in the eastern half of the study area where they compose the Hickory aquifer (in Upper Cambrian rocks), Ellenburger-San Saba aquifer (Upper Cambrian- Lower Ordovician), and Marble Falls aquifer (Lower Pennsylvanian). These aquifers are hydraulically connected to the northeastern fringe of the Edwards-Trinity aquifer system, as their up-turned margins crop out around the flanks of the breached Llano uplift. The Rustler aquifer in rocks of Late Permian age underlies parts of the Trans-Pecos region, where it yields small amounts of greatly mineralized water for industrial and agricultural purposes. The Dockum aquifer in rocks of Late Triassic age directly underlies the Edwards-Trinity aquifer system in western parts of the study area, and locally increases the saturated thickness of the ground-water-flow system by an average of about 200 feet. Despite these notable exceptions, the collective effect of the pre-Cretaceous rocks is that 01 a barrier to ground-water flow, which limits the exchange of water across the base of the Edwards-Trinity aquifer system.

Texas

Distribution and altitude of the top of saline ground water in the southeastern Coastal Plain

A map prepared by the U.S. Geological Survey shows the approximate distribution of saline water (greater than 10,000 mg/L as NaCl) in the Southeastern Coastal Plain. The primary distribution of saline water is in Cretaceous sediments and may be characterized as an extensive body of fluid whose upper surface generally slopes upward from inland toward coastal areas. Some freshwater appears to occupy parts of the deeper water-bearing zones in Georgia. A small amount of saline water appears to occupy a narrow upper zone of limited extent in lower Tertiary sediments in Georgia and parts of South Carolina. The freshwater-saline water interface for the lower zone lies offshore, east of the South Carolina coast. Consequently, the saline water distribution is inferred offshore.

southeastern Coastal Plain