USGS ScienceSearch

Geology topics

Michael J. Lockhart

Publications and source records attributed to Michael J. Lockhart.

2 recordsLinked to original sources

Demographic implications of lead poisoning for eagles across North America

Lead poisoning occurs worldwide in populations of predatory birds, but exposure rates and population impacts are known only from regional studies. We evaluated the lead exposure of 1210 bald and golden eagles from 38 US states across North America, including 620 live eagles. We detected unexpectedly high frequencies of lead poisoning of eagles, both chronic (46 to 47% of bald and golden eagles, as measured in bone) and acute (27 to 33% of bald eagles and 7 to 35% of golden eagles, as measured in liver, blood, and feathers). Frequency of lead poisoning was influenced by age and, for bald eagles, by region and season. Continent-wide demographic modeling suggests that poisoning at this level suppresses population growth rates for bald eagles by 3.8% (95% confidence interval: 2.5%, 5.4%) and for golden eagles by 0.8% (0.7%, 0.9%). Lead poisoning is an underappreciated but important constraint on continent-wide populations of these iconic protected species.

Science

Evaluating a rapid field assessment system for anticoagulant rodenticide exposure of raptors

Anticoagulant rodenticides (ARs) are commonly used to control rodent pests. However, worldwide, their use is associated with secondary and tertiary poisoning of nontarget species, especially predatory and scavenging birds. No medical device can rapidly test for AR exposure of avian wildlife. Prothrombin time (PT) is a useful biomarker for AR exposure, and multiple commercially available point-of-care (POC) devices measure PT of humans, and domestic and companion mammals. We evaluated the potential of one commercially available POC device, the Coag-Sense ® PT/INR Monitoring System, to rapidly detect AR exposure of living birds of prey. The Coag-Sense device delivered repeatable PT measurements on avian blood samples collected from four species of raptors trapped during migration (Intraclass Correlation Coefficient > 0.9; overall intra-sample variation CV: 5.7%). However, PT measurements reported by the Coag-Sense system from 81 ferruginous hawk ( Buteo regalis ) nestlings were not correlated to those measured by a one-stage laboratory avian PT assay ( r = − 0.017, p = 0.88). Although precise, the lack of agreement in PT estimates from the Coag-Sense device and the laboratory assay indicates that this device is not suitable for detecting potential AR exposure of birds of prey. The lack of suitability may be related to the use of a mammalian reagent in the clotting reaction, suggesting that the device may perform better in testing mammalian wildlife

Archives of Environmental Contamination and Toxico