Responses of a 58-story RC dual core shear wall and outrigger frame building inferred from two earthquakes

Responses of a dual core shear-wall and outrigger-framed 58-story building recorded during the M w 6.0 Napa earthquake of 24 August 2014 and the M w 3.8 Berkeley earthquake of 20 October 2011 are used to identify its dynamic characteristics and behavior. Fundamental frequencies are 0.28 Hz (NS), 0.25 Hz (EW), and 0.43 Hz (torsional). Rigid body motions due to rocking are not significant. Average drift ratios are small. Outrigger frames do not affect average drift ratios or mode shapes. Local site effects do not affect the response; however, response associated with deeper structure may be substantial. A beating effect is observed from data of both earthquakes but beating periods are not consistent. Low critical damping ratios may have contributed to the beating effect. Torsion is relatively larger above outriggers as indicated by the time-histories of motions at the roof, possibly due to the discontinuity of the stiffer shear walls above level 47.

California

An investigation of soil-structure interaction effects observed at the MIT Green Building

The soil-foundation impedance function of the MIT Green Building is identified from its response signals recorded during an earthquake. Estimation of foundation impedance functions from seismic response signals is a challenging task, because: (1) the foundation input motions (FIMs) are not directly measurable, (2) the as-built properties of the super-structure are only approximately known, and (3) the soil-foundation impedance functions are inherently frequency-dependent. In the present study, aforementioned difficulties are circumvented by using, in succession, a blind modal identification (BMID) method, a simplified Timoshenko beam model (TBM), and a parametric updating of transfer functions (TFs). First, the flexible-base modal properties of the building are identified from response signals using the BMID method. Then, a flexible-base TBM is updated using the identified modal data. Finally, the frequency-dependent soil-foundation impedance function is estimated by minimizing the discrepancy between TFs (of pairs instrumented floors) that are (1) obtained experimentally from earthquake data and (2) analytically from the updated TBM. Using the fully identified flexible-base TBM, the FIMs as well as building responses at locations without instruments can be predicted, as demonstrated in the present study.

Massachussets

Responses of a tall building in Los Angeles, California as inferred from local and distant earthquakes

Increasing inventory of tall buildings in the United States and elsewhere may be subjected to motions generated by near and far seismic sources that cause long-period effects. Multiple sets of records that exhibited such effects were retrieved from tall buildings in Tokyo and Osaka ~ 350 km and 770 km from the epicenter of the 2011 Tohoku earthquake. In California, very few tall buildings have been instrumented. An instrumented 52-story building in downtown Los Angeles recorded seven local and distant earthquakes. Spectral and system identification methods exhibit significant low frequencies of interest (~0.17 Hz, 0.56 Hz and 1.05 Hz). These frequencies compare well with those computed by transfer functions; however, small variations are observed between the significant low frequencies for each of the seven earthquakes. The torsional and translational frequencies are very close and are coupled. Beating effect is observed in at least two of the seven earthquake data.

Earthquake Spectra

Responses of a tall building with U.S. code-type instrumentation in Tokyo, Japan, to events before, during and after the Tohoku earthquake of 11 March 2011

The 11 March 2011 M 9.0 Tohoku earthquake generated long-duration shaking that propagated hundreds of kilometers from the epicenter and affected tall buildings in urban areas several hundred kilometers from the epicenter of the main shock. Recorded responses show that tall buildings were affected by long-period motions. This study presents the behavior and performance of a 37-story building in the Tsukuda area of Tokyo, Japan, as inferred from modal analyses of records retrieved for a time interval covering a few days before, during, and for several months after the main shock. The U.S. “code-type” array comprises three triaxial accelerometers deployed at three levels in the superstructure. Such a sparse array in a tall structure limits a reliable assessment, because its performance must be based on only the average drift ratios. Based on the inferred values of this parameter, the subject building was not structurally damaged.

Toyko

Responses of two tall buildings in Tokyo, Japan, before, during, and after the M9.0 Tohoku earthquake of 11 March 2011

The 11 March 2011 M 9.0 Tohoku earthquake generated significant long duration shaking that propagated hundreds of kilometers from the epicenter and affected urban areas throughout much of Honshu. Recorded responses of tall buildings at several hundred km from the epicenter of the main shock and other events show tall buildings were affected by long-period motions of events at distant sources. This study presents behavioral aspects of 29-story and 30-story neighboring buildings in the Shinjuku area of Tokyo, Japan, as inferred from records retrieved from a sparse array of accelerometers deployed in the superstructures, at ground and 100 m below the ground level over a time interval covering before, during, and after the main shock. Such long-period effects are common in several regions of Japan as well as in the United States and in other seismically active countries. Permanent shifts in fundamental frequencies are observed. Drift ratios indicate possible structural nonlinear behavior occurred during the main shock. The need to consider risks to built environments from distant sources, including those in neighboring countries, is emphasized.

Tokyo

Blind identification of the Millikan Library from earthquake data considering soil–structure interaction

The Robert A. Millikan Library is a reinforced concrete building with a basement level and nine stories above the ground. Located on the campus of California Institute of Technology (Caltech) in Pasadena California, it is among the most densely instrumented buildings in the U.S. From the early dates of its construction, it has been the subject of many investigations, especially regarding soil–structure interaction effects. It is well accepted that the structure is significantly interacting with the surrounding soil, which implies that the true foundation input motions cannot be directly recorded during earthquakes because of inertial effects. Based on this limitation, input–output modal identification methods are not applicable to this soil–structure system. On the other hand, conventional output-only methods are typically based on the unknown input signals to be stationary whitenoise, which is not the case for earthquake excitations. Through the use of recently developed blind identification (i.e. output-only) methods, it has become possible to extract such information from only the response signals because of earthquake excitations. In the present study, we employ such a blind identification method to extract the modal properties of the Millikan Library. We present some modes that have not been identified from force vibration tests in several studies to date. Then, to quantify the contribution of soil–structure interaction effects, we first create a detailed Finite Element (FE) model using available information about the superstructure; and subsequently update the soil–foundation system's dynamic stiffnesses at each mode such that the modal properties of the entire soil–structure system agree well with those obtained via output-only modal identification.

California

Unusual downhole and surface free-field records near the Carquinez Strait bridges during the 24 August 2014 Mw6.0 South Napa, California earthquake

This paper reports the results of Part A of a study of the recorded strong-motion accelerations at the well-instrumented network of the two side-by-side parallel bridges over the Carquinez Strait during the 24 August 2014 (Mw6.0 ) South Napa, Calif. earthquake that occurred at 03:20:44 PDT with epicentral coordinates 38.22N, 122.31W. (http://earthquake.usgs.gov/earthquakes/eqarchives/poster/2014/20140824.php, last accessed on October 17, 2014). Both bridges and two boreholes were instrumented by the California Strong motion Instrumentation Program (CSMIP) of California Geological Survey (CGS) (Shakal et al., 2014). A comprehensive comparison of several ground motion prediction equations as they relate to recorded ground motions of the earthquake is provided by Baltay and Boatright (2015).

California

Rocking behavior of an instrumented unique building on the MIT campus identified from ambient shaking data

A state-of-the-art seismic monitoring system comprising 36 accelerometers and a data-logger with real-time capability was recently installed at Building 54 on the Massachusetts Institute of Technology's (MIT) Cambridge, MA, campus. The system is designed to record translational, torsional, and rocking motions, and to facilitate the computation of drift between select pairs of floors. The cast-in-place, reinforced concrete building is rectangular in plan but has vertical irregularities. Heavy equipment is installed asymmetrically on the roof. Spectral analyses and system identification performed on five sets of low-amplitude ambient data reveal distinct and repeatable fundamental translational frequencies in the structural NS and EW directions (0.75 Hz and 0.68 Hz, respectively), a torsional frequency of 1.49 Hz, a rocking frequency of 0.75 Hz, and very low damping. Such results from low-amplitude data serve as a baseline against which to compare the behavior and performance of the building during stronger shaking caused by future earthquakes in the region.

Masachusetts

Drift issues of tall buildings during the March 11, 2011 M9.0 Tohoku earthquake, Japan - Implications

One of the most significant effects of the M9.0 Tohoku, Japan earthquake of March 11, 2011 is the now well-known long duration (>10 minutes) shaking of buildings in Japan – particularly those in Tokyo (~350-375 km from the epicenter) and in places as far as Osaka (~770 km from the epicenter). Although none collapsed, the strong shaking caused many tall buildings not to be functional for days and weeks. The purpose of this paper is to discuss the behavior and performance of four tall buildings, considered to be representative of most tall buildings in Tokyo and other locations, and from which shaking data were retrieved. Of particular interest is a building in Osaka that almost reached an average of 0.5% drift ratio – this, with a ground level input motion of ~3% g is significant. What might have happened during an event with input level motions with similar low frequency content and in 10-20% g range is a legitimate question that must be pondered. The particular building had serious site effects and was in resonance. The other three examples are from Tokyo. For example, based on records obtained from a 54-story building retrofitted with 288 oil dampers on 24 floors, computations show that average drift ratio may have reached ~0.3% and maximum drift ratio likely was > .3%. The maximum allowed by Japanese practice for buildings taller than 60 m and for collapse protection (level 2) motions is 1% (The Building Center of Japan, 2001). Performances of tall buildings in many seismically active regions of the world (e.g. Chile, Turkey) or those tall buildings affected by long distance long period effects by sources at a distance (e.g. Abu Dhabi, Dubai) are of interest to the earthquake engineering community. Chile imposes 0.2 % drift limit that result in elastic design. USA and Turkey impose 2% drift limit. Such wide variations of drift limits in design practices deserve discussion in light of functionality and performance of tall buildings during the 2011 Tohoku event.

Conference Paper

Identifying the dynamic characteristics of a dual core-wall and frame building in Chile using aftershocks of the 27 February 2010 (M w =8.8) Maule, Chile, earthquake

Following the 27 February 2010 (M w = 8.8) Offshore Maule, Chile earthquake, a temporary, 16-channel, real-time data streaming array was installed in a recently constructed building in Viña del Mar to capture its responses to aftershocks. The cast-in-place, reinforced concrete building is 16 stories high, with 3 additional basement levels, and has dual system comprising multiple structural walls and perimeter frames. This building was not damaged during the main-shock, but other buildings of similar design in Viña del Mar and other parts of Chile were damaged, although none collapsed. Dynamic characteristics of the building identified from the low-amplitude (PGA of about 2 Gal) response recordings of aftershocks are found to compare well with those determined from modal analyses using a design level FEM model. Distinct “major-axes” translational and torsional fundamental frequencies, as well as frequencies of secondary modes, are identified. Evidence of beating is consistently observed in the response data for each earthquake. Results do not match well with U.S. code formulas.

Talca Province

Response of a tall building far from the epicenter of the 11 March 2011 M 9.0 Great East Japan earthquake and aftershocks

The 11 March 2011 M 9.0 Great East Japan earthquake generated significant long-duration shaking that propagated hundreds of kilometers from the epicenter and affected urban areas throughout much of Honshu. Recorded responses of a tall building at 770 km from the epicenter of the mainshock and other related or unrelated events show how structures sensitive to long-period motions can be affected by distant sources. Even when the largest peak input motions to the building is about 3% g , the strong-shaking duration was about 140 s. The 300- to 1000-s prolonged responses of the building are primarily due to a combination of site resonance (e.g. structural fundamental frequency ~0.15 Hz and site frequency ~0.13–0.17 Hz) and low damping (~1–2%) of the structure. Response modification technologies can improve the response of the building during future earthquakes. The need-to-consider risks to such built environments from distant sources are emphasized.

Honshu

Golden Gate Bridge response: a study with low-amplitude data from three earthquakes

The dynamic response of the Golden Gate Bridge, located north of San Francisco, CA, has been studied previously using ambient vibration data and finite element models. Since permanent seismic instrumentation was installed in 1993, only small earthquakes that originated at distances varying between ~11 to 122 km have been recorded. Nonetheless, these records prompted this study of the response of the bridge to low amplitude shaking caused by three earthquakes. Compared to previous ambient vibration studies, the earthquake response data reveal a slightly higher fundamental frequency (shorter-period) for vertical vibration of the bridge deck center span (~7.7–8.3 s versus 8.2–10.6 s), and a much higher fundamental frequency (shorter period) for the transverse direction of the deck (~11.24–16.3 s versus ~18.2 s). In this study, it is also shown that these two periods are dominant apparent periods representing interaction between tower, cable, and deck.

California

Ambient response of a unique performance-based design building with dynamic response modification features

A 64-story, performance-based design building with reinforced concrete core shear-walls and unique dynamic response modification features (tuned liquid sloshing dampers and buckling-restrained braces) has been instrumented with a monitoring array of 72 channels of accelerometers. Ambient vibration data recorded are analyzed to identify modes and associated frequencies and damping. The low-amplitude dynamic characteristics are considerably different than those computed from design analyses, but serve as a baseline against which to compare with future strong shaking responses. Such studies help to improve our understanding of the effectiveness of the added features to the building and help improve designs in the future.

California

Reassessment of probabilistic seismic hazard in the Marmara region

In 1999, the eastern coastline of the Marmara region (Turkey) witnessed increased seismic activity on the North Anatolian fault (NAF) system with two damaging earthquakes (M 7.4 Kocaeli and M 7.2 D??zce) that occurred almost three months apart. These events have reduced stress on the western segment of the NAF where it continues under the Marmara Sea. The undersea fault segments have been recently explored using bathymetric and reflection surveys. These recent findings helped scientists to understand the seismotectonic environment of the Marmara basin, which has remained a perplexing tectonic domain. On the basis of collected new data, seismic hazard of the Marmara region is reassessed using a probabilistic approach. Two different earthquake source models: (1) the smoothed-gridded seismicity model and (2) fault model and alternate magnitude-frequency relations, Gutenberg-Richter and characteristic, were used with local and imported ground-motion-prediction equations. Regional exposure is computed and quantified on a set of hazard maps that provide peak horizontal ground acceleration (PGA) and spectral acceleration at 0.2 and 1.0 sec on uniform firm-rock site condition (760 m=sec average shear wave velocity in the upper 30 m). These acceleration levels were computed for ground motions having 2% and 10% probabilities of exceedance in 50 yr, corresponding to return periods of about 2475 and 475 yr, respectively. The maximum PGA computed (at rock site) is 1.5g along the fault segments of the NAF zone extending into the Marmara Sea. The new maps generally show 10% to 15% increase for PGA, 0.2 and 1.0 sec spectral acceleration values across much of Marmara compared to previous regional hazard maps. Hazard curves and smooth design spectra for three site conditions: rock, soil, and soft-soil are provided for the Istanbul metropolitan area as possible tools in future risk estimates.

Bulletin of the Seismological Society of America

Status and needs for seismic instrumentation of structures along the Hayward fault

The inventory of structures in heavily urbanized communities within the greater San Francisco (SF) Bay area that will experience strong ground motions from the rupture of the Hayward Fault includes a variety of types of recent and older structures built with a variety of materials and to different code standards. Those who remember the effects of the 1989 Loma Prieta earthquake on structures in the San Francisco Bay area also remember the collapse of one upper-deck segment of the Bay Bridge that halted transportation for approximately five weeks. In order to understand how these structures respond to earthquake motions and to improve building practices to resist these strong motions it is imperative that owners of these structures as well as governmental organizations acquire shaking response data from instrumented (or yet to be instrumented structures) during the forecast events. Within California, such data are acquired mainly by California Geological Survey and the United States Geological Survey. A small number of private owners contribute to this effort. The inventory of existing instrumented structures is much less than 0.1% of the total, and thus statistically it is not sufficient. For example, some of the existing important regular or lifeline structures are not instrumented(e.g. Bart Trans-Bay Tunnel, many segments of the Bart elevated structures in the proximity of the Hayward Fault, the yet to be completed eastern part of San Francisco Bay Bridge, Hetch-Hetchy pipeline system crossing the Hayward Fault)even though attempts and proposals have been developed to do so in the past. This paper presents a critical assessment of the status quo and the future needs for instrumentation of structures in the greater SF Bay area that includes the Hayward Fault. There are many new attempts and successes in instrumentation of structures in this region. Two successful examples are provided here, but more needs to be done. The paper does not present new research results; hence, it should be considered to be a “tutorial” paper.

California