Surface-water, water-quality, and ground-water assessment of the Municipio of Ponce, Puerto Rico, 2002-2004
Explore the source record for details and available documents.
Geology topics
Publications and source records attributed to Luis Santiago-Rivera.
Explore the source record for details and available documents.
The surface-water assessment portion of this study focused on analysis of low-flow characteristics in local streams and rivers, because the supply of safe drinking water was a critical issue during recent dry periods. Low-flow characteristics were evaluated at one continuous-record gaging station based on graphical curve-fitting techniques and log-Pearson Type III frequency curves. Estimates of low-flow characteristics for 20 partial-record stations were generated using graphical-correlation techniques. Flow-duration characteristics for the continuous- and partial-record stations were estimated using the relation curves developed for the low-flow study. Stream low-flow statistics document the general hydrology under current land use, water-use, and climatic conditions. A survey of streams and rivers utilized 37 sampling stations to evaluate the sanitary quality of about 165 miles of stream channels. River and stream samples for fecal coliform and fecal streptococcus analyses were collected on two occasions at base-flow conditions. Bacteriological analyses indicate that a significant portion of the stream reaches within the municipio of Mayaguez may have fecal coliform bacteria concentrations above the water-quality goal (standard) established by the Puerto Rico Environmental Quality Board (Junta de Calidad Ambiental de Puerto Rico) for inland surface waters. Sources of fecal contamination may include: illegal discharge of sewage to storm-water drains, malfunctioning sanitary sewer ejectors, clogged and leaking sewage pipes, septic tank leakage, unfenced livestock, and runoff from livestock pens. Long-term fecal coliform data from five sampling stations located within or in the vicinity of the municipio of Mayaguez have been in compliance with the water-quality goal for fecal coliform concentration established in July 1990. Geologic, topographic, soil, hydrogeologic, and streamflow data were compiled into a database and used to divide the municipio of Mayaguez into five hydrogeologic terranes. This integrated database then was used to evaluate the ground-water potential of each hydrogeologic terrane. Lineament-trace analysis was used to help assess the ground-water development potential in the hydrogeologic terranes containing igneous rocks. Analyses suggest that areas with slopes greater than 15 degrees have relatively low ground-water development potential. The presence of fractures, independent of the topographic slope, may locally enhance the water-bearing properties in the hydrogeologic terranes containing igneous rocks. The results of this study indicate that induced streamflow generally is needed to sustain low to moderate ground-water withdrawal rates in the five hydrogeologic terranes. The ground-water flow systems in the hydrogeologic terranes are only able to sustain small withdrawal rates that rarely exceed 50 gallons per minute. Areas with a high density of fractures, as could be the case at the intersection of lineament traces in the upper parts of the Rio Ca?as and Rio Yaguez watersheds, are worthy of exploratory drilling for ground-water development.
Explore the source record for details and available documents.
To meet the increasing need for a safe and adequate supply of water in the municipio of Comerio, an integrated surface-water, water-quality, and ground-water assessment of the area was conducted. The major results of this study and other important hydrologic and water-quality features were compiled in a Geographic Information System, and are presented in two 1:30,000-scale map plates to facilitate interpretation and use of the diverse water-resource data. Because the supply of safe drinking water was a critical issue during recent dry periods, the surface-water assessment portion of this study focused on analysis of low-flow characteristics in local streams and rivers. Low-flow characteristics were evaluated at one continuous-record gaging station based on graphical curve-fitting techniques and log-Pearson Type III frequency curves. Estimates of low-flow characteristics for 13 partial-record stations were generated using graphical-correlation techniques. Flow-duration characteristics for the continuous- and partial-record stations were estimated using the relation curves developed for the low-flow study. Stream low-flow statistics document the general hydrology under current land- and water-use conditions. A sanitary quality survey of streams utilized 24 sampling stations to evaluate about 84 miles of stream channels with drainage to or within the municipio of Comerio. River and stream samples for fecal coliform and fecal streptococcus analyses were collected on two occasions at base-flow conditions to evaluate the sanitary quality of streams. Bacteriological analyses indicate that about 27 miles of stream reaches within the municipio of Comerio may have fecal coliform bacteria concentrations above the water-quality goal established by the Puerto Rico Environmental Quality Board (Junta de Calidad Ambiental de Puerto Rico) for inland surface waters. Sources of fecal contamination may include illegal discharge of sewage to storm-water drains, malfunction of sanitary sewer ejectors, clogged and leaking sewage pipes, septic tank leakage, unfenced livestock, runoff from livestock pens, and seepage from pits containing animal wastes. Long-term fecal coliform data at two sampling stations on the Rio de la Plata indicate that since 1984, the geometric mean of five consecutive samples commonly has been at or below 2,000 colonies per 100 milliliters (established as the sanitary quality goal in Puerto Rico for Class SD type waters). At the sampling station upstream of Comerio, the geometric mean concentration has been near 500 colonies per 100 milliliters; downstream of the town of Comerio, the geometric mean concentration has been near 2,000 colonies per 100 milliliters concentration. The data at these stations also indicate that fecal coliform concentrations increase commonly above 2,000 colonies per 100 milliliters during storm-runoff events, ranging from 1,000 to 100,000 colonies per 100 milliliters at both stations. Geologic, topographic, soil, hydrogeologic, and streamflow data were used to divide the municipio of Comerio into five hydrogeologic terranes. The integrated database was then used to evaluate the ground-water development potential of each hydrogeologic terrane. Analysis suggests that areas with slopes greater than 15 degrees have relatively low ground-water development potential. Fractures may be important locally in enhancing the water-bearing properties in the hydrogeologic terranes containing igneous rocks. The integrated hydrogeologic approach used in this study can serve as an important tool for regulatory agencies of Puerto Rico and the municipio of Comerio to evaluate the ground-water resource development potential, examine ground- and surface-water interaction, and determine the effect of land-use practices on ground-water quantity and quality. Stream low-flow statistics document the general hydrology under current land and water uses. Low-flow characteristics may substantially change as a re
To meet the increasing need for a safe and adequate supply of water in the municipio of Carolina, an integrated surface-water, water-quality, and ground-water assessment of the area was conducted. The major results of this study and other important hydrologic and water-quality features were compiled in a Geographic Information System and are presented in two 1:30,000-scale map plates to facilitate interpretation and use of the diverse water-resources data. Because the supply of safe drinking water was a critical issue during recent dry periods, the surface-water assessment portion of this study focused on analysis of low-flow characteristics in local streams and rivers. Low-flow characteristics were evaluated for one continuous-record gaging station, based on graphical curve-fitting techniques and log-Pearson Type III frequency analysis. Estimates of low-flow characteristics for seven partial-record stations were generated using graphical-correlation techniques. Flow-duration characteristics were computed for the one continuous-record gaging station and were estimated for the partial-record stations using the relation curves developed from the low-flow study. Stream low-flow statistics document the general hydrology under current land and water use. Low-flow statistics may substantially change as a result of streamflow diversions for public supply, and an increase in ground-water development, waste-water discharges, and flood-control measures; the current analysis provides baseline information to evaluate these impacts and develop water budgets. A sanitary quality survey of streams utilized 29 sampling stations to evaluate the sanitary quality of about 87 miles of stream channels. River and stream samples were collected on two occasions during base-flow conditions and were analyzed for fecal coliform and fecal streptococcus. Bacteriological analyses indicate that a significant portion of the stream reaches within the municipio of Carolina may have fecal coliform concentrations above the water-quality goal established by the Puerto Rico Environmental Quality Board (Junta de Calidad Ambiental de Puerto Rico) for inland surface waters. Sources of fecal contamination may include: illegal discharge of sewage to storm-water drains, malfunctioning sanitary sewer ejectors, clogged and leaking sewage pipes, septic tank leakage, unfenced livestock, and runoff from livestock pens. Long-term fecal coliform data at two sampling stations, Quebrada Blasina in Carolina and the Rio Grande de Loiza, downstream from the town of Trujillo Alto, indicate that the sanitary quality of Quebrada Blasina is and has generally been poor for more than a decade. The sanitary quality of the Rio Grande de Loiza has generally been in compliance with the water-quality goal standard fecal coliform concentrations established in July 1990 by the Puerto Rico Environmental Quality Board. Geologic, topographic, soil, hydrogeologic, and streamflow data were used to divide the municipio of Carolina into five hydrogeologic terranes. This integrated database was then used to evaluate the ground-water potential of each hydrogeologic terrane. Analysis suggests that areas with slopes greater than 15 degrees have relatively low ground-water development potential. Fractures may be locally important in enhancing the water-bearing properties in the hydrogeologic terranes containing igneous rocks. Potentiometric-surface elevations recorded in piezometers installed in the coastal area during this study were used to define ground-water flow directions in the hydrogeologic terranes composed of coastal plain clastic and limestone units. The resultant potentiometric map indicates that the coastal plain aquifer and streams in the lowland parts of the municipio of Carolina are hydraulically connected. The potentiometric map also indicates that ground-water discharge to the Rio Grande de Loiza, downstream from highway PR-3, has been enhanced by dredging of the streambed for
Knowledge of the magnitude and frequency of low flows is important for the optimal development of surface-water resources in Puerto Rico. This report presents analyses of low-flow data for 9 continuous-record gaging stations and 105 partial-record stations in southern and western Puerto Rico. The report includes analyses of lowflow data and tabulations of computed low-flow magnitude and frequency characteristics for 7-, 14-, 30-, 60-, and 90-consecutive days with recurrence intervals of 2 and 10 years for continuous-record gaging stations based on the log-Pearson Type III frequency distribution or graphically adjusted logPearson frequency curves. Estimates of low-flow characteristics are provided for partial-record stations for 7-, 14-, and 30-consecutive days with recurrence intervals of 2 and 10 years. Low-flow characteristics at partial-record stations were estimated based on the relation of base-flow discharge measurements at the partial-record stations and concurrent discharges at nearby continuous-record stations.