USGS ScienceSearch

Geology topics

Kevin R. Henke

Publications and source records attributed to Kevin R. Henke.

4 recordsLinked to original sources

Gas emissions, tars, and secondary minerals at the Ruth Mullins and Tiptop coal mine fires

Both the Tiptop and Ruth Mullins coal fires, Kentucky, were reinvestigated in 2009 and 2010. The Tiptop fire was not as active in 2009 and may have been on the path to burning out at the time of the 2009 visit. The Ruth Mullins coal mine fire, Perry County, Kentucky, has been the subject of several field investigations, including November 2009–February 2010 investigations in which we measured gas emissions, collected minerals and tars, and characterized the nature of the fire. Vents exhibiting the greatest gas flux (>100,000 mg/s/m 2 ) are those with the largest amount of condensate minerals and tars. Vents with moderate gas flux (10,000–100,000 mg/s/m 2 ) are less likely to contain condensate minerals, but are collocated with tars, and vents with the lowest flux (<10,000 mg/s/m 2 ) generally lack both minerals and tars. Aliphatic hydrocarbons present in the gases include C1-C9 compounds, and aromatics include BTEX compounds. Diffuse-CO 2 emissions are concentrated along the fracture zones overlying abandoned mine works. The area of peak diffuse flux corresponds to the trend of the collapsed portal that forms vent 5. The greatest vent emissions were also recorded at vent 5. The snow-melt zone mapped in January 2010 overlies the areas of peak diffuse-CO 2 emissions measured in November; together they delineate the zone of active combustion. Comparison of greenhouse gas emissions from the two sources shows that vent emissions exceed diffuse emissions. The highly fractured, quartz-cemented roof rock funnels the majority of emissions toward the vents. Significant decreases are seen in estimates of yearly greenhouse emissions based on data gathered from November 2009 to February 2010, with estimates from November significantly exceeding any previously published estimates. For example, September 2009 estimates from vent 3 alone indicated that 19 ± 7.5 T CO 2 /yr were emitted while the November 2009 estimates were 1800 ± 690 T/yr. Barometric pressure was lower in November than September. This implies that there are many factors influencing the seasonal variations in fire emissions and that more frequent monitoring will be necessary to derive accurate estimates of coal fires' contribution to the carbon budget.

Kentucky

Quantifying greenhouse gas emissions from coal fires using airborne and ground-based methods

Coal fires occur in all coal-bearing regions of the world and number, conservatively, in the thousands. These fires emit a variety of compounds including greenhouse gases. However, the magnitude of the contribution of combustion gases from coal fires to the environment is highly uncertain, because adequate data and methods for assessing emissions are lacking. This study demonstrates the ability to estimate CO 2 and CH 4 emissions for the Welch Ranch coal fire, Powder River Basin, Wyoming, USA, using two independent methods: (a) heat flux calculated from aerial thermal infrared imaging (3.7–4.4 t d −1 of CO 2 equivalent emissions) and (b) direct, ground-based measurements (7.3–9.5 t d −1 of CO 2 equivalent emissions). Both approaches offer the potential for conducting inventories of coal fires to assess their gas emissions and to evaluate and prioritize fires for mitigation.

International Journal of Coal Geology

CO 2 , CO, and Hg emissions from the Truman Shepherd and Ruth Mullins coal fires, eastern Kentucky, USA

Carbon dioxide (CO 2 ), carbon monoxide (CO), and mercury (Hg) emissions were quantified for two eastern Kentucky coal-seam fires, the Truman Shepherd fire in Floyd County and the Ruth Mullins fire in Perry County. This study is one of the first to estimate gas emissions from coal fires using field measurements at gas vents. The Truman Shepherd fire emissions are nearly 1400 t CO 2 /yr and 16 kg Hg/yr resulting from a coal combustion rate of 450–550 t/yr. The sum of CO 2 emissions from seven vents at the Ruth Mullins fire is 726 ± 72 t/yr, suggesting that the fire is consuming about 250–280 t coal/yr. Total Ruth Mullins fire CO and Hg emissions are estimated at 21 ± 1.8 t/yr and > 840 ± 170 g/yr, respectively. The CO 2 emissions are environmentally significant, but low compared to coal-fired power plants; for example, 3.9 × 10 6 t CO 2 /yr for a 514-MW boiler in Kentucky. Using simple calculations, CO 2 and Hg emissions from coal-fires in the U.S. are estimated at 1.4 × 10 7 – 2.9 × 10 8 t/yr and 0.58–11.5 t/yr, respectively. This initial work indicates that coal fires may be an important source of CO 2 , CO, Hg and other atmospheric constituents.

Kentucky

The Tiptop coal-mine fire, Kentucky: Preliminary investigation of the measurement of mercury and other hazardous gases from coal-fire gas vents

The Tiptop underground coal-mine fire in the Skyline coalbed of the Middle Pennsylvanian Breathitt Formation was investigated in rural northern Breathitt County, Kentucky, in May 2008 and January 2009, for the purpose of determining the concentrations of carbon dioxide (CO2), carbon monoxide (CO), and mercury (Hg) in the vent and for measuring gas-vent temperatures. At the time of our visits, concentrations of CO2 peaked at 2.0% and > 6.0% (v/v) and CO at 600 ppm and > 700 ppm during field analysis in May 2008 and January 2009, respectively. For comparison, these concentrations exceed the U.S. Occupational Safety & Health Administration (OSHA) eight-hour safe exposure limits (0.5% CO2 and 50 ppm CO), although the site is not currently mined. Mercury, as Hg0, in excess of 500 and 2100 μg/m3, in May and January, respectively, in the field, also exceeded the OSHA eight-hour exposure limit (50 μg/m3). Carbonyl sulfide, dimethyl sulfide, carbon disulfide, and a suite of organic compounds were determined at two vents for the first sampling event. All gases are diluted by air as they exit and migrate away from a gas vent, but temperature inversions and other meteorological conditions could lead to unhealthy concentrations in the nearby towns. Variation in gas temperatures, nearly 300 °C during the January visit to the fire versus < 50 °C in May, demonstrates the large temporal variability in fire intensity at the Tiptop mine. These preliminary results suggest that emissions from coal fires may be important, but additional data are required that address the reasons for significant variations in the composition, flow, and temperature of vent gases.

Kentucky