USGS ScienceSearch

Geology topics

J. L. Barker

Publications and source records attributed to J. L. Barker.

5 recordsLinked to original sources

SLC-off Landsat-7 ETM+ reflective band radiometric calibration

Since May 31, 2003, when the scan line corrector (SLC) on the Landsat-7 ETM+ failed, the primary foci of Landsat-7 ETM+ analyses have been on understanding and attempting to fix the problem and later on developing composited products to mitigate the problem. In the meantime, the Image Assessment System personnel and vicarious calibration teams have continued to monitor the radiometric performance of the ETM+ reflective bands. The SLC failure produced no measurable change in the radiometric calibration of the ETM+ bands. No trends in the calibration are definitively present over the mission lifetime, and, if present, are less than 0.5% per year. Detector 12 in Band 7 dropped about 0.5% in response relative to the rest of the detectors in the band in May 2004 and recovered back to within 0.1% of its initial relative gain in October 2004.

Conference Paper

Landsat-7 ETM+ on-orbit reflective-band radiometric stability and absolute calibration

Launched in April 1999, the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument is in its sixth year of operation. The ETM+ instrument has been the most stable of any of the Landsat instruments. To date, the best onboard calibration source for the reflective bands has been the Full Aperture Solar Calibrator, a solar-diffuser-based system, which has indicated changes of between 1% to 2% per year in the ETM+ gain for bands 1-4 and 8 and less than 0.5%/year for bands 5 and 7. However, most of this change is believed to be caused by changes in the solar diffuser panel, as opposed to a change in the instrument's gain. This belief is based partially on vicarious calibrations and observations of "invariant sites", hyperarid sites of the Sahara and Arabia. Weighted average slopes determined from these datasets suggest changes of 0.0% to 0.4% per year for bands 1-4 and 8 and 0.4% to 0.5% per year for bands 5 and 7. Absolute calibration of the reflective bands of the ETM+ is consistent with vicarious observations and other sensors generally at the 5% level, though there appear to be some systematic differences.

IEEE Transactions on Geoscience and Remote Sensing

Landsat-7 ETM+ radiometric calibration: Two years on-orbit

Landsat-7 has been in orbit for 2 years as of April 15, 2001 and operationally providing calibrated data products for 2 years as of June 28, 2001. A radiometric calibration team consisting of scientists and analysts from the Landsat Project Science Office, the Landsat-7 Image Assessment System and four universities evaluates the calibration based on on-board and ground-look (vicarious) calibration methodologies. The results are assembled and compared semi-annually and the calibration parameter files are adjusted as necessary. To date the combined results for the reflective bands have not shown any change from pre-launch values. The pre-launch values continue to be used for data processing, with the uncertainty estimated at less than 5%. In the thermal band, the vicarious calibration results indicated a 0.31 W/m/sup 2/ sr /spl mu/m bias in the calibration. This bias results in the ETM+ derived temperatures being about 3K high. The calibration parameter file was updated October 1, 2000 to remove this bias, however the U.S. Landsat Product Generation System (LPGS) software required modification that was not incorporated until December 20, 2000. All LPGS data products generated since this date have the correct thermal band calibration, regardless of image acquisition date, with uncertainties at approximately the 1% level.

Conference Paper

Compilation of ground water quality data in Pennsylvania

The U.S. Geological Survey's water quality file of 4,671 wells and springs in Pennsylvania provided ground-water-quality data for Pennsylvania. The data were assembled into computer-readable format and sorted into 15 major aquifer groups based on principal lithology, physiographic province, and age. Nineteen variables in each group were summarized by the Statistical Analysis Systems UNIVARIATE procedures to produce descriptive statistics including extreme values and quartiles. The bulk of the water-quality data are in the important aquifers in the unconsolidated Coastal Plain sediments, the Triassic sedimentary rocks, the igneous and metamorphic rocks, and the carbonate rocks. On the other hand, water-quality data for aquifer groups in the Appalachian Plateau and Valley and Ridge Province are sparse. Statewide, only six wells provide sufficient long-term data for trend analyses. Ground-water quality in Pennsylvania is highly diverse. High concentrations of dissolved solids, iron, manganese, sulfate, and nitrate are prevalent forms of natural and manmade contamination. The unconsolidated Coastal Plain aquifers have been most severely degraded. On the other hand, some of the best quality water is found in the quartzite, sandstone, and conglomerate rock units in the Cambrian and Precambrian rocks.

Open-File Report

Water-quality assessment of Francis E. Walter Reservoir, Luzerne and Carbon counties, Pennsylvania

Water-quality data, both past and present, show that the waters of the upper Lehigh River basin are somewhat acidic, but otherwise are generally of good quality. This report contains a summary of all known water-quality data collected by the U.S. Geological Survey and other agencies, as well as a synopsis of current water-quality conditions in the reservoir and its tributaries. Water-quality data collected from June 1981 to May 1982 indicate that raising the pool level from 1,300 to approximately 1,392 feet above sea level (NGVD of 1929) has had some significant, if only temporary, detrimental impacts on the reservoir system and its discharge. Depth profile measurements show that, while the impoindment was thermally stratified for only about 2 weeks, the dissolved oxygen concentrations were depressed to levels critical to fishlife throughout much of the reservoir. Another effect of the raised pool was the lowering of pH in the impoinded water. Median pH values were less than 6.0 throughout the reservoir, whereas they commonly exceeded 6.5 at the normal pool elevation. Tests for fecal coliform and fecal streptococcus indicate the impoinded water is nearly free of enteric bacteria. Algal analyses and nutrient concentrations support the premise that the impoundment is nutrient poor and phosphorus limited. Raising the water level an additional 125 feet should have no permanent detrimental effect upon water quality and will greatly increase available habitat for fish and waterflow. Increased retention time should not alter the current trophic status and may decrease the concentration of available nutrients.

Pennsylvania