USGS Science⌕ Search

Geology topics

J. L. Barker

Publications and source records attributed to J. L. Barker.

14 recordsLinked to original sources

Landsat-7 Enhanced Thematic Mapper plus radiometric calibration

Landsat-7 is currently being built and tested for launch in 1998. The Enhanced Thematic Mapper Plus (ETM+) sensor for Landsat-7, a derivative of the highly successful Thematic Mapper (TM) sensors on Landsats 4 and 5, and the Landsat-7 ground system are being built to provide enhanced radiometric calibration performance. In addition, regular vicarious calibration campaigns are being planned to provide additional information for calibration of the ETM+ instrument. The primary upgrades to the instrument include the addition of two solar calibrators: the full aperture solar calibrator, a deployable diffuser, and the partial aperture solar calibrator, a passive device that allows the ETM+ to image the sun. The ground processing incorporates for the first time an off-line facility, the Image Assessment System (IAS), to perform calibration, evaluation and analysis. Within the IAS, processing capabilities include radiometric artifact characterization and correction, radiometric calibration from the multiple calibrator sources, inclusion of results from vicarious calibration and statistical trending of calibration data to improve calibration estimation. The Landsat Product Generation System, the portion of the ground system responsible for producing calibrated products, will incorporate the radiometric artifact correction algorithms and will use the calibration information generated by the IAS. This calibration information will also be supplied to ground processing systems throughout the world.

Canadian Journal of Remote Sensing↗

A definitive calibration record for the Landsat-5 thematic mapper anchored to the Landsat-7 radiometric scale

A coordinated effort on the part of several agencies has led to the specification of a definitive radiometric calibration record for the Landsat-5 thematic mapper (TM) for its lifetime since launch in 1984. The time-dependent calibration record for Landsat-5 TM has been placed on the same radiometric scale as the Landsat-7 enhanced thematic mapper plus (ETM+). It has been implemented in the National Landsat Archive Production Systems (NLAPS) in use in North America. This paper documents the results of this collaborative effort and the specifications for the related calibration processing algorithms. The specifications include (i) anchoring of the Landsat-5 TM calibration record to the Landsat-7 ETM+ absolute radiometric calibration, (ii) new time-dependent calibration processing equations and procedures applicable to raw Landsat-5 TM data, and (iii) algorithms for recalibration computations applicable to some of the existing processed datasets in the North American context. The cross-calibration between Landsat-5 TM and Landsat-7 ETM+ was achieved using image pairs from the tandem-orbit configuration period that was programmed early in the Laridsat-7 mission. The time-dependent calibration for Landsat-5 TM is based on a detailed trend analysis of data from the on-board internal calibrator. The new lifetime radiometric calibration record for Landsat-5 will overcome problems with earlier product generation owing to inadequate maintenance and documentation of the calibration over time and will facilitate the quantitative examination of a continuous, near-global dataset at 30-m scale that spans almost two decades.

Canadian Journal of Remote Sensing↗

On-orbit performance of the Landsat-7 ETM+ radiometric calibrators

The Landsat-7 Enhanced Thematic Mapper Plus (ETM+) incorporates two new devices to improve its absolute radiometric calibration: a Full Aperture Solar Calibrator (FASC) and a Partial Aperture Solar Calibrator (PASC). The FASC is a diffuser panel, typically deployed once per month. Initial FASC absolute calibration results were within 5% of the pre-launch calibrations. Over time, the responses of the ETM+ to the FASC have varied with the location viewed on the panel, suggesting a localized degradation or contamination of the panel. On the best part of the panel, the trends in response range from m 1.4% y m 1 (band 4) to +0.6% y m 1 (band 7), with band 5 showing the least change at m 0.4% y m 1 . Changes in the panel reflectance due to UV exposure are believed to be the origin of these trends. The PASC is a set of auxiliary optics that allows the ETM+ to image the Sun through reduced apertures. PASC data have normally been acquired on a daily basis. Unlike the FASC, the PASC has exhibited significant anomalies. During the first six months of operation, responses to the PASC increased up to 60%, sending bands 2, 3 and 8 into saturation (band 1 was saturated at launch). The short-wave infrared (SWIR) band individual detectors have shown variations up to - 20% in response to the PASC. The variation is different for each detector. After the first six months, the responses to the PASC have become more stable, with much of the variation related to the within-scan position of the solar image. Overall results to date for all calibrators and comparisons with vicarious calibrations indicate that most of the response variations have been due to the calibrators themselves and suggest that the instrument has been stable with changes in response of less than 0.5% y m 1 .

International Journal of Remote Sensing↗

SLC-off Landsat-7 ETM+ reflective band radiometric calibration

Since May 31, 2003, when the scan line corrector (SLC) on the Landsat-7 ETM+ failed, the primary foci of Landsat-7 ETM+ analyses have been on understanding and attempting to fix the problem and later on developing composited products to mitigate the problem. In the meantime, the Image Assessment System personnel and vicarious calibration teams have continued to monitor the radiometric performance of the ETM+ reflective bands. The SLC failure produced no measurable change in the radiometric calibration of the ETM+ bands. No trends in the calibration are definitively present over the mission lifetime, and, if present, are less than 0.5% per year. Detector 12 in Band 7 dropped about 0.5% in response relative to the rest of the detectors in the band in May 2004 and recovered back to within 0.1% of its initial relative gain in October 2004.

Conference Paper↗

Landsat-7 ETM+ on-orbit reflective-band radiometric stability and absolute calibration

Launched in April 1999, the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument is in its sixth year of operation. The ETM+ instrument has been the most stable of any of the Landsat instruments. To date, the best onboard calibration source for the reflective bands has been the Full Aperture Solar Calibrator, a solar-diffuser-based system, which has indicated changes of between 1% to 2% per year in the ETM+ gain for bands 1-4 and 8 and less than 0.5%/year for bands 5 and 7. However, most of this change is believed to be caused by changes in the solar diffuser panel, as opposed to a change in the instrument's gain. This belief is based partially on vicarious calibrations and observations of "invariant sites", hyperarid sites of the Sahara and Arabia. Weighted average slopes determined from these datasets suggest changes of 0.0% to 0.4% per year for bands 1-4 and 8 and 0.4% to 0.5% per year for bands 5 and 7. Absolute calibration of the reflective bands of the ETM+ is consistent with vicarious observations and other sensors generally at the 5% level, though there appear to be some systematic differences.

IEEE Transactions on Geoscience and Remote Sensing↗

Landsat-7 ETM+ radiometric stability and absolute calibration

Launched in April 1999, the Landsat-7 ETM+ instrument is in its fourth year of operation. The quality of the acquired calibrated imagery continues to be high, especially with respect to its three most important radiometric performance parameters: reflective band instrument stability to better than ??1%, reflective band absolute calibration to better than ??5%, and thermal band absolute calibration to better than ??0.6 K. The ETM+ instrument has been the most stable of any of the Landsat instruments, in both the reflective and thermal channels. To date, the best on-board calibration source for the reflective bands has been the Full Aperture Solar Calibrator, which has indicated changes of at most -1.8% to -2.0% (95% C.I.) change per year in the ETM+ gain (band 4). However, this change is believed to be caused by changes in the solar diffuser panel, as opposed to a change in the instrument's gain. This belief is based partially on ground observations, which bound the changes in gain in band 4 at -0.7% to +1.5%. Also, ETM+ stability is indicated by the monitoring of desert targets. These image-based results for four Saharan and Arabian sites, for a collection of 35 scenes over the three years since launch, bound the gain change at -0.7% to +0.5% in band 4. Thermal calibration from ground observations revealed an offset error of +0.31 W/m 2 sr um soon after launch. This offset was corrected within the U. S. ground processing system at EROS Data Center on 21-Dec-00, and since then, the band 6 on-board calibration has indicated changes of at most +0.02% to +0.04% (95% C.I.) per year. The latest ground observations have detected no remaining offset error with an RMS error of ??0.6 K. The stability and absolute calibration of the Landsat-7 ETM+ sensor make it an ideal candidate to be used as a reference source for radiometric cross-calibrating to other land remote sensing satellite systems.

Conference Paper↗

Landsat-7 ETM+ radiometric calibration: Two years on-orbit

Landsat-7 has been in orbit for 2 years as of April 15, 2001 and operationally providing calibrated data products for 2 years as of June 28, 2001. A radiometric calibration team consisting of scientists and analysts from the Landsat Project Science Office, the Landsat-7 Image Assessment System and four universities evaluates the calibration based on on-board and ground-look (vicarious) calibration methodologies. The results are assembled and compared semi-annually and the calibration parameter files are adjusted as necessary. To date the combined results for the reflective bands have not shown any change from pre-launch values. The pre-launch values continue to be used for data processing, with the uncertainty estimated at less than 5%. In the thermal band, the vicarious calibration results indicated a 0.31 W/m/sup 2/ sr /spl mu/m bias in the calibration. This bias results in the ETM+ derived temperatures being about 3K high. The calibration parameter file was updated October 1, 2000 to remove this bias, however the U.S. Landsat Product Generation System (LPGS) software required modification that was not incorporated until December 20, 2000. All LPGS data products generated since this date have the correct thermal band calibration, regardless of image acquisition date, with uncertainties at approximately the 1% level.

Conference Paper↗

Water quality of the Upper West Branch Susquehanna River and tributary streams between Curwensville and Renovo, Pennsylvania, May and July 1984

The soils and rocks of the Upper West Branch Susquehanna River basin, from its headwaters downstream for 150 miles, are laden with pyritic materials that have the potential to produce acid mine drainage. The effects of mine drainage are severe, particularly in the reach between Curwensville and Renovo where present water quality cannot support viable populations of benthic macroinvertebrates or fish. During base-flow periods in May and July 1984, streamflow and water quality were measured at four sites on the West Branch Susquehanna River and near the mouths of 94 tributaries. Water-quality constituents determined were temperature, specific conductance, pH, acidity, alkalinity, and concentrations of dissolved sulfate and total and dissolved forms of iron, manganese, aluminum, and zinc. The data collected for the study indicate that the predominant influence on water quality of the tributaries is land use. An area where few or no coal deposits or disturbed area were present was found to have relatively good surface-water quality (median pH was nearly 5.5 units), whereas areas where coal mining was active in the basin, or where large areas of unreclaimed mines were present, were found to have poorest water quality (median pH was generally less than 4.0 units). In general, Moshannon, Sinnemahoning, Clearfield, and Kettle Creeks were found to be the largest tributary sources of acidity and total-recoverable iron to the river. During the May sampling, Moshannon, Sinnemahoning, and Clearfield Creeks contributed 63 percent of the 365 tons/day of acidity, and Moshannon and Clearfield Creeks contributed 76 percent of the 44.8 tons/day of total-recoverable iron that were discharged to the river. During the July sampling, Moshannon, Kettle, and Clearfield Creeks contributed 60 percent of the 131 tons/day of acidity, and Moshannon and Kettle Creeks contributed 51 percent of the 6.5 tons/day of total-recoverable iron discharged to the river . The West Branch Susquehanna River was found to have pH ranging from 5.4 to 6.5 units and specific conductance ranging from 267 to 310 microsiemens per centimeter at the most upstream site at Curwensville. The water quality was most degraded at the site at Karthaus (pH 3.9 to 4.1 units, specific conductance 330 to 610 microsiemens per centimeter). Quality gradually improved downstream to the site at Renovo (pH 3.8 to 4.6 units, specific conductance 200 to 392 microsiemens per centimeter), although the quality did not recover to that found at Curwensville.

Water-Resources Investigations Report↗

Effects of acidic precipitation on the water quality of streams in the Laurel Hill area, Somerset County, Pennsylvania, 1983-86

Five headwater streams in the Laurel Hill area in southwestern Pennsylvania were investigated from September 1983 through February 1986 to determine possible effects of acidic precipitation on water quality. Precipitation in the Laurel Hill area is among the most acidic in the Nation, with a mean volume-weighted pH of 4.06. Sulfate is the dominant acid-forming anion, averaging 3.6 milligrams per liter or about 50 kilograms per hectare in wet deposition alone. Nitrate averages about 2 milligrams per liter or 7 kilograms per hectare in the study area. Stream chemistry in the five streams is quite variable and apparently is influenced to a large degree by the bedrock geology and by small amounts of alkaline material in watershed soils. Three of the five streams with no or little acid-neutralizing capacity presently are devoid of fish because of low pH and elevated aluminum concentrations. Aluminum concentrations increase in the other two streams during rainfall and snowmelt despite comparatively higher base flow and acid-neutralizing capacities. Comparison of the chemistry of streamflow during 14 storm events at South Fork Bens Creek and North Fork Bens Creek reveals similar chemical responses when discharge suddenly increases. Concentrations of dissolved metals and sulfate increased during stormflow and snowmelt runoff, whereas concentrations of base cations, silica, and chloride decreased. Nitrate concentrations were not affected by rainfall runoff by tended to increase with snowmelt runoff.

Pennsylvania↗

Water quality of the West Branch Lackawaxen River and limnology of Prompton Lake, Wayne County, Pennsylvania, October 1986 through September 1987

The water quality of the West Branch Lackawaxen River and the limnology of Prompton Lake in northeastern Pennsylvania were studied from October 1986 through September 1987 to determine past and present water-quality conditions in the basin, and to determine the possible effects of raising the lake level on the water quality of the Lake, of the river downstream, and of ground water. Past and present water quality of the West Branch Lackawaxen River and Prompton Lake generally meets State standards for high-quality waters that sup- port the maintenance and propagation of cold-water fishes. However, suggested criteria by the U.S. Environmental Protection Agency intended to control excessive algal growth in the lake are exceeded most, if not all, of the time for nitrogen and most of the time for phosphorus. The average annual total nitrogen load entering the lake is 114 tons. Of this total, 41 tons is inorganic nitrate plus nitrate, 48 tons organic nitrogen, and 25 tons ammonia nitrogen. Estimated annual yields of total nitrogen, inorganic nitrite plus nitrate, organic nitrogen, and ammonia nitrogen are 1.9, 9.7, 0.8, and 0.4 tons/mi2 (tons per square mile), respectively. The average annual phosphorus load is estimated to be 4.7 tons, which is equivalent to a yield of 0.08 tons/mi2. About 62 percent, or 2.9 tons, is dissolved phosphorus that is readily available for plant assimilation. The waters of the West Branch Lackawaxen River and Prompton Lake are decidedly phosphorus limited. The long-term average annual suspended-sediment yield to the lake is about 70 tons/mi2. Life expectancy of the 774 acre-feet of space allocated for sediment loads in the raised pool is estimated to be about 287 years. During the 1987 water year, about 51 percent of the annual sediment load was transported during 7 days by storm-water runoff. The maximum sediment discharge during the study period was 400 tons per day. Lake-profile studies show that thermal and chemical stratification develops in early June and persists through September. Water below a depth of about 20 feet becomes anoxic, or nearly so, by mid-July. Summer concentrations of chlorophyll are indicative of eutropic conditions. Although raising of the lake level is expected to increase the efficiency of the lake in trapping nutrients, the increased depth and volume will reduce the concentrations of available nutrients and, thereby, reduce the eutrophication potential of the lake. The water level in about 30 wells near the lake probably will rise after the lake level is raised, and the well yields probably will increase slightly. Flow of water form the lake to the aquifer as the lake is being raised may temporarily increase mineral content of water in the aquifer. After a new equilibrium is reached, however, water will again flow from the aquifer to the lake, thereby restoring the aquifer's water quality.

Water-Resources Investigations Report↗

Temporal changes in sulfate, chloride, and sodium concentrations in four eastern Pennsylvania streams

Trend analyses of 20 years or more of chemical quality and streamflow data for four streams in eastern Pennsylvania indicate that sulfate has decreased significantly in three of the four basins studied, while sodium and chloride have generally increased. The majority of chemical quality changes occurred in the late 1950 's and early 1960 's coincident with significant cultural changes. It is believed that these chemical quality changes are presently of little or no environmental consequence, as the concentrations are well within the range of those found in natural waters. Decreases in sulfate follow a regional trend concurrent with the conversion of home and industrial heating units from high to low sulfur coal, gas, and oil. The most significant decreases were observed in those basins severely affected by mine-drainage where pumpage has decreased significantly in the past 25 years, thereby further reducing the sulfur content of the streams. The observed increases in chloride and sodium are attributed to population increases and shifts from rural to suburban communities with concurrent increase in the percentage of the population using municipal waste treatment facilities and the increased use of salt on roadways. The concentrations of dissolved chloride, which are from two to three times higher in recent years, reach a peak in January, coincident with the application of salt to melt ice on the roadways. (USGS)

Water-Resources Investigations Report↗

Compilation of ground water quality data in Pennsylvania

The U.S. Geological Survey's water quality file of 4,671 wells and springs in Pennsylvania provided ground-water-quality data for Pennsylvania. The data were assembled into computer-readable format and sorted into 15 major aquifer groups based on principal lithology, physiographic province, and age. Nineteen variables in each group were summarized by the Statistical Analysis Systems UNIVARIATE procedures to produce descriptive statistics including extreme values and quartiles. The bulk of the water-quality data are in the important aquifers in the unconsolidated Coastal Plain sediments, the Triassic sedimentary rocks, the igneous and metamorphic rocks, and the carbonate rocks. On the other hand, water-quality data for aquifer groups in the Appalachian Plateau and Valley and Ridge Province are sparse. Statewide, only six wells provide sufficient long-term data for trend analyses. Ground-water quality in Pennsylvania is highly diverse. High concentrations of dissolved solids, iron, manganese, sulfate, and nitrate are prevalent forms of natural and manmade contamination. The unconsolidated Coastal Plain aquifers have been most severely degraded. On the other hand, some of the best quality water is found in the quartzite, sandstone, and conglomerate rock units in the Cambrian and Precambrian rocks.

Open-File Report↗

Water-quality assessment of Francis E. Walter Reservoir, Luzerne and Carbon counties, Pennsylvania

Water-quality data, both past and present, show that the waters of the upper Lehigh River basin are somewhat acidic, but otherwise are generally of good quality. This report contains a summary of all known water-quality data collected by the U.S. Geological Survey and other agencies, as well as a synopsis of current water-quality conditions in the reservoir and its tributaries. Water-quality data collected from June 1981 to May 1982 indicate that raising the pool level from 1,300 to approximately 1,392 feet above sea level (NGVD of 1929) has had some significant, if only temporary, detrimental impacts on the reservoir system and its discharge. Depth profile measurements show that, while the impoindment was thermally stratified for only about 2 weeks, the dissolved oxygen concentrations were depressed to levels critical to fishlife throughout much of the reservoir. Another effect of the raised pool was the lowering of pH in the impoinded water. Median pH values were less than 6.0 throughout the reservoir, whereas they commonly exceeded 6.5 at the normal pool elevation. Tests for fecal coliform and fecal streptococcus indicate the impoinded water is nearly free of enteric bacteria. Algal analyses and nutrient concentrations support the premise that the impoundment is nutrient poor and phosphorus limited. Raising the water level an additional 125 feet should have no permanent detrimental effect upon water quality and will greatly increase available habitat for fish and waterflow. Increased retention time should not alter the current trophic status and may decrease the concentration of available nutrients.

Pennsylvania↗