USGS ScienceSearch

Geology topics

J. Jeffrey Starn

Publications and source records attributed to J. Jeffrey Starn.

22 records · Page 2Linked to original sources

Aquifer chemistry and transport processes in the zone of contribution to a public-supply well in Woodbury, Connecticut, 2002-06

A glacial aquifer system in Woodbury, Connecticut, was studied to identify factors that affect the groundwater quality in the zone of contribution to a community public-supply well. Water samples were collected during 2002-06 from the public-supply well and from 35 monitoring wells in glacial stratified deposits, glacial till, and fractured bedrock. The glacial aquifer is vulnerable to contamination from a variety of sources due to the short groundwater residence times and the urban land use in the contributing recharge area to the public-supply well. The distribution and concentrations of pH, major and trace elements, stable isotope ratios, recharge temperatures, dissolved organic carbon (DOC), and volatile organic compounds (VOCs), and the oxidation-reduction (redox) conditions, were used to identify recharge source areas, aquifer source material, anthropogenic sources, chemical processes, and groundwater-flow paths from recharge areas to the public-supply well, PSW-1. The major chemical sources to groundwater and the tracers or conditions used to identify them and their processes throughout the aquifer system include (1) bedrock and glacial stratified deposits and till, characterized by high pH and concentrations of sulfate (SO42-), bicarbonate, uranium (U), radon-222, and arsenic (As) relative to those of other wells, reducing redox conditions, enriched delta sulfur-34 (d34S) and delta carbon-13 (d13C) values, depleted delta oxygen-18 (d18O) and delta deuterium (dD) values, calcite near saturation, low recharge temperatures, and groundwater ages of more than about 9 years; (2) natural organic matter, either in sediments or in an upgradient riparian zone, characterized by high concentrations of DOC or manganese (Mn), low concentrations of dissolved oxygen (DO) and nitrate (NO3-), enriched d34S values, and depleted d18O and dD values; (3) road salt (halite), characterized by high concentrations of sodium (Na), chloride (Cl-), and calcium (Ca), and indicative chloride/bromide (Cl:Br) mass concentration ratios; (4) septic-system leachate, characterized by high concentrations of NO3-, DOC, Na, Cl-, Ca, and boron (B), delta nitrogen-15 (d15N) and d18O values, and indicative Cl:Br ratios; (5) organic solvent spills, characterized by detections of perchloroethene (PCE), trichloroethene (TCE), and 1,1-dichloroethene (1,1-DCE); (6) gasoline station spills, characterized by detections of fuel oxygenates and occasionally benzene; and (7) surface-water leakage, characterized by enriched d18O and dD values and sometimes high DOC and Mn-reducing conditions. Evaluation of Cl- concentrations and Cl:Br ratios indicates that most samples were composed of mixtures of groundwater and some component of road salt or septic-system leachate. Leachate from septic-tank drainfields can cause locally anoxic conditions with NO3- concentrations of as much as 19 milligrams per liter (mg/L as N) and may provide up to 15 percent of the nitrogen in water from well PSW-1, based on mixing calculations with d15N of NO3-. Most of the water that contributes to PSW-1 is young (less than 7 years) and derived from the glacial stratified deposits. Typically, groundwater is oxic, but localized reducing zones that result from abundances of organic matter can affect the mobilization of trace elements and the degradation of VOCs. Groundwater from fractured bedrock beneath the valley bottom, which is old (more than 50 years), and reflects a Mn-reducing to methanic redox environment, constitutes as much as 6 percent of water samples collected from monitoring wells screened at the bottom of the glacial aquifer. Dissolved As and U concentrations generally are near the minimum reporting level (MRL) (0.2 micrograms per liter or ?g/L and 0.04 ?g/L, respectively), but water from a few wells screened in glacial deposits, likely derived from underlying organic-rich Mesozoic rocks, contain As concentrations up to 7 ?g/L. At one location, concentrations of As and U were high

Scientific Investigations Report

Simulations of Ground-Water Flow and Residence Time near Woodbury, Connecticut

Water withdrawn for public use from glacial stratified deposits in Woodbury, Connecticut, is a mixture of water from different source areas, each having a characteristic water-quality signature. The physical processes leading to this mixture were explored using a numerical model to simulate steady-state ground-water source areas and residence times for a public water-supply well (PSW-1) in Woodbury. Upland areas contribute water to the well that is primarily from undeveloped and agricultural land. Valley bottoms contribute water to the well that is primarily from developed land. From 1985 to 2002, 6 percent of the contributing recharge area to the well changed from agricultural and undeveloped to developed land. The pattern of recharge areas and land use causes stratification of ground water by residence time and by characteristic water quality, which is related to land use. As land use changes with time, the water-quality signature of developed land moves deeper into the aquifer. Predicted nitrate concentrations decreased from 1985 to 1995 because of the conversion from agricultural land to developed land, but then began to increase after 1995 because of the conversion of undeveloped land to developed land. Total dissolved solids concentrations, on the other hand, increased from 1985 to 2002 because agriculture is associated with lower total dissolved solids concentrations than is developed land. About 40 percent of the water withdrawn from PSW-1 originated as upland recharge before flowing through glacial deposits in the valley. About 44 percent of the water originated as recharge in either fluvial deposits (mean residence time 7 years) or deltaic deposits (mean residence time 4 years). About 16 percent of the water originated as recharge through storm drains with ground-water discharge (often known as 'dry wells'). The residence time for water that originated as recharge in dry wells is 2 to 4 years, and the mean residence time is 3 years. Dry wells are a fast pathway for water to enter the aquifer and provide a significant amount of water to PSW-1; therefore, PSW-1 is more susceptible to contamination in runoff from the commercial area, which enters the dry wells, than to recharge elsewhere in the area. Water withdrawn from a well is a mixture of waters with different residence times, and a single residence time does not fully characterize the susceptibility of the well to recent contamination. The mean simulated flow-weighted residence time in PSW-1 is 6 years, which compares reasonably well with the apparent residence time measured using tritium/helium data of 6 and 7 years (samples for age dating were collected twice from this well). There are at least two modes to the distribution of ages, one mode with residence times less than 5 years and one mode with residence times greater than 5 years. About 34 percent of the ground-water in PSW-1 is younger than 5 years and 56 percent of the water is from 5 to 9 years. The estimated nitrate loading rate from a single-family septic system is 18 grams per day. If each household in the contributing recharge area contributes nitrate at that loading rate to the well PSW-1, each additional septic system in the contributing recharge area is responsible for a 0.045-milligram-per-liter increase in nitrate at PSW-1 at the current pumping rate. Uncertainty in the predicted contributing recharge area can be propagated through the analysis using a Monte Carlo technique. There is a greater degree of certainty in the delineation of the recharge area near the well, and as one moves from the well toward the recharge areas, the uncertainty in the model increases. The area that possibly contributes water to the well using the Monte Carlo model is much larger than the recharge area delineated using the optimal parameter estimates. Within the probabilistic recharge area, the number of septic systems could be twice the number initially estimated.

Scientific Investigations Report

Simulation of ground-water flow to assess geohydrologic factors and their effect on source-water areas for bedrock wells in Connecticut

Generic ground-water-flow simulation models show that geohydrologic factors?fracture types, fracture geometry, and surficial materials?affect the size, shape, and location of source-water areas for bedrock wells. In this study, conducted by the U.S. Geological Survey in cooperation with the Connecticut Department of Public Health, ground-water flow was simulated to bedrock wells in three settings?on hilltops and hillsides with no surficial aquifer, in a narrow valley with a surficial aquifer, and in a broad valley with a surficial aquifer?to show how different combinations of geohydrologic factors in different topographic settings affect the dimensions and locations of source-water areas in Connecticut. Three principal types of fractures are present in bedrock in Connecticut?(1) Layer-parallel fractures, which developed as partings along bedding in sedimentary rock and compositional layering or foliation in metamorphic rock (dips of these fractures can be gentle or steep); (2) unroofing joints, which developed as strain-release fractures parallel to the land surface as overlying rock was removed by erosion through geologic time; and (3) cross fractures and joints, which developed as a result of tectonically generated stresses that produced typically near-vertical or steeply dipping fractures. Fracture geometry is defined primarily by the presence or absence of layering in the rock unit, and, if layered, by the angle of dip in the layering. Where layered rocks dip steeply, layer-parallel fracturing generally is dominant; unroofing joints also are typically well developed. Where layered rocks dip gently, layer-parallel fracturing also is dominant, and connections among these fractures are provided only by the cross fractures. In gently dipping rocks, unroofing joints generally do not form as a separate fracture set; instead, strain release from unroofing has occurred along gently dipping layer-parallel fractures, enhancing their aperture. In nonlayered and variably layered rocks, layer-parallel fracturing is absent or poorly developed; fracturing is dominated by well-developed subhorizontal unroofing joints and steeply dipping, tectonically generated fractures and (or) cooling joints. Cross fractures (or cooling joints) in nonlayered and variably layered rocks have more random orientations than in layered rocks. Overall, nonlayered or variably layered rocks do not have a strongly developed fracture direction. Generic ground-water-flow simulation models showed that fracture geometry and other geohydrologic factors affect the dimensions and locations of source-water areas for bedrock wells. In general, source-water areas to wells reflect the direction of ground-water flow, which mimics the land-surface topography. Source-water areas to wells in a hilltop setting were not affected greatly by simulated fracture zones, except for an extensive vertical fracture zone. Source-water areas to wells in a hillside setting were not affected greatly by simulated fracture zones, except for the combination of a subhorizontal fracture zone and low bedrock vertical hydraulic conductivity, as might be the case where an extensive subhorizontal fracture zone is not connected or is poorly connected to the surface through vertical fractures. Source-water areas to wells in a narrow valley setting reflect complex ground-water-flow paths. The typical flow path originates in the uplands and passes through either till or bedrock into the surficial aquifer, although only a small area of the surficial aquifer actually contributes water to the well. Source-water areas in uplands can include substantial areas on both sides of a river. Source-water areas for wells in this setting are affected mainly by the rate of ground-water recharge and by the degree of anisotropy. Source-water areas to wells in a broad valley setting (bedrock with a low angle of dip) are affected greatly by fracture properties. The effect of a given fracture is to channel the

Scientific Investigations Report

Delineation and Analysis of Uncertainty of Contributing Areas to Wells at the Southbury Training School, Southbury, Connecticut

Contributing areas to public-supply wells at the Southbury Training School in Southbury, Connecticut, were mapped by simulating ground-water flow in stratified glacial deposits in the lower Transylvania Brook watershed. The simulation used nonlinear regression methods and informational statistics to estimate parameters of a ground-water flow model using drawdown data from an aquifer test. The goodness of fit of the model and the uncertainty associated with model predictions were statistically measured. A watershed-scale model, depicting large-scale ground-water flow in the Transylvania Brook watershed, was used to estimate the distribution of groundwater recharge. Estimates of recharge from 10 small basins in the watershed differed on the basis of the drainage characteristics of each basin. Small basins having well-defined stream channels contributed less ground-water recharge than basins having no defined channels because potential ground-water recharge was carried away in the stream channel. Estimates of ground-water recharge were used in an aquifer-scale parameter-estimation model. Seven variations of the ground-water-flow system were posed, each representing the ground-water-flow system in slightly different but realistic ways. The model that most closely reproduced measured hydraulic heads and flows with realistic parameter values was selected as the most representative of the ground-water-flow system and was used to delineate boundaries of the contributing areas. The model fit revealed no systematic model error, which indicates that the model is likely to represent the major characteristics of the actual system. Parameter values estimated during the simulation are as follows: horizontal hydraulic conductivity of coarse-grained deposits, 154 feet per day; vertical hydraulic conductivity of coarse-grained deposits, 0.83 feet per day; horizontal hydraulic conductivity of fine-grained deposits, 29 feet per day; specific yield, 0.007; specific storage, 1.6E-05. Average annual recharge was estimated using the watershed-scale model with no parameter estimation and was determined to be 24 inches per year in the valley areas and 9 inches per year in the upland areas. The parameter estimates produced in the model are similar to expected values, with two exceptions. The estimated specific yield of the stratified glacial deposits is lower than expected, which could be caused by the layered nature of the deposits. The recharge estimate produced by the model was also lower?about 32 percent of the average annual rate. This could be caused by the timing of the aquifer test with respect to the annual cycle of ground-water recharge, and by some of the expected recharge going to parts of the flow system that were not simulated. The data used in the calibration were collected during an aquifer test from October 30 to November 4, 1996. The model fit was very good, as indicated by the correlation coefficient (0.999) between the weighted simulated values and weighted observed values. The model also reproduced the general rise in ground-water levels caused by ground-water recharge and the cyclic fluctuations caused by pumping prior to the aquifer test. Contributing areas were delineated using a particle-tracking procedure. Hypothetical particles of water were introduced at each model cell in the top layer and were tracked to determine whether or not they reached the pumped well. A deterministic contributing area was calculated using the calibrated model, and a probabilistic contributing area was calculated using a Monte Carlo approach along with the calibrated model. The Monte Carlo simulation was done, using the parameter variance/covariance matrix generated by the regression model, to estimate probabilities associated with the contributing area to the wells. The probabilities arise from uncertainty in the estimated parameter values, which in turn arise from the adequacy of the data available to comprehensively describe the groundwater-flow sy

Water-Resources Investigations Report