Stable isotope reference materials and scale definitions – Outcomes of the 2024 IAEA experts meeting

The participants of the 12 th International Atomic Energy Agency (IAEA) meeting on stable isotope reference materials reached a consensus, acknowledging the existence and use of two carbon isotope delta scales: the VPDB (Vienna Peedee belemnite) scale and the VPDB-LSVEC (LSVEC - lithium carbonate prepared by H. J. Svec). Conversion models between the two scales can be established and used but introduce uncertainty. A format for isotope delta scale definition was agreed upon and was used to define the two carbon isotope delta scales and the two main oxygen isotope delta scales, VSMOW-SLAP (Vienna Standard Mean Ocean Water–Standard Light Antarctic Precipitation) and VPDB. Confirmation or identification of a second-scale–defining point is still necessary for the nitrogen and sulfur isotope delta scales. Efforts are encouraged to improve consistency among laboratories in the isotopic analysis of “non-exchangeable hydrogen” in bulk organic materials and oxygen in carbonates using the phosphoric acid reaction. Additional topics discussed include (1) need for improvement in reference materials for accurate greenhouse gas isotopic analyses; (2) reference materials under production by the IAEA, the US Geological Survey (USGS), and the US National Institute of Standards and Technology (NIST); (3) methods for value and uncertainty assignment of reference materials; and (4) calculation of carbon-13 isotope delta and oxygen-18 isotope delta of CO 2 measured by dual-inlet isotope ratio mass spectrometry.

Rapid Communications in Mass Spectrometry↗

Final report on pilot study CCQM-P211: Carbon isotope delta measurements of vanillin

This pilot study was conducted in parallel to the key comparison CCQM-K167. Vials containing 0.25 mg of vanillin were prepared at NRC and distributed to four participating institutes. Institutes could choose any suitable reference materials and methodology to perform carbon isotope delta measurements. Participants reported analysis details, and a carbon isotope delta value and associated uncertainty for the vanillin sample. Each of the carbon isotope delta results of vanillin were compared to the KCRV established from CCQM-K167, and metrological compatibility to the KCRV was determined. Three expert laboratories participated in this study, and their reported results serve as a benchmark to compare the performance of all other participants to these world-class institutes.

Metrologia↗

USGS44, a new high-purity calcium carbonate reference material for δ13C measurements

Rationale The stable carbon isotopic ( δ 13 C) reference material (RM) LSVEC Li 2 CO 3 has been found to be unsuitable for δ 13 C standardization work because its δ 13 C value increases with exposure to atmospheric CO 2 . A new CaCO 3 RM, USGS44, has been prepared to alleviate this situation. Methods USGS44 was prepared from 8 kg of Merck high-purity CaCO 3 . Two sets of δ 13 C values of USGS44 were determined. The first set of values was determined by online combustion, continuous-flow (CF) isotope-ratio mass spectrometry (IRMS) of NBS 19 CaCO 3 ( δ 13 C VPDB = +1.95 milliurey (mUr) exactly, where mUr = 0.001 = 1‰), and LSVEC Li 2 CO 3 ( δ 13 C VPDB = −46.6 mUr exactly), and normalized to the two-anchor δ 13 C VPDB-LSVEC isotope-delta scale. The second set of values was obtained by dual-inlet (DI)-IRMS of CO 2 evolved by reaction of H 3 PO 4 with carbonates, corrected for cross contamination, and normalized to the single-anchor δ 13 C VPDB scale. Results USGS44 is stable and isotopically homogeneous to within 0.02 mUr in 100-μg amounts. It has a δ 13 C VPDB-LSVEC value of −42.21 ± 0.05 mUr. Single-anchor δ 13 C VPDB values of −42.08 ± 0.01 and −41.99 ± 0.02 mUr were determined by DI-IRMS with corrections for cross contamination. Conclusions The new high-purity, well-homogenized calcium carbonate isotopic reference material USGS44 is stable and has a δ 13 C VPDB-LSVEC value of −42.21 ± 0.05 mUr for both EA/IRMS and DI-IRMS measurements. As a carbonate relatively depleted in 13 C, it is intended for daily use as a secondary isotopic reference material to normalize stable carbon isotope delta measurements to the δ 13 C VPDB-LSVEC scale. It is useful in quantifying drift with time, determining mass-dependent isotopic fractionation (linearity correction), and adjusting isotope-ratio-scale contraction. Due to its fine grain size (smaller than 63 μm), it is not suitable as a δ 18 O reference material. A δ 13 C VPDB-LSVEC value of −29.99 ± 0.05 mUr was determined for NBS 22 oil.

Rapid Communications in Mass Spectrometry↗

New organic reference materials for hydrogen, carbon, and nitrogen stable isotope-ratio measurements: caffeines, n-alkanes, fatty acid methyl esters, glycines, L-valines, polyethylenes, and oils

An international project developed, quality-tested, and determined isotope−δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope−δ scales. The RMs span a range of δ 2 H VSMOW-SLAP values from −210.8 to +397.0 mUr or ‰, for δ 13 C VPDB-LSVEC from −40.81 to +0.49 mUr and for δ 15 N Air from −5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C 16 n -alkanes, n -C 20 -fatty acid methyl esters (FAMEs), glycines, and l -valines, together with polyethylene powder and string, one n -C 17 -FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a 2 H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ 2 H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain 13 C and carbon-bound organic 2 H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.

Analytical Chemistry↗

On-line hydrogen-isotope measurements of organic samples using elemental chromium: An extension for high temperature elemental-analyzer techniques

The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ 2 H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ 2 H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while handling water as a bulk sample. The calibration of organic samples, commonly having high δ 2 H values, will benefit from the availability of suitably 2 H-enriched reference waters, extending the VSMOW-SLAP scale above zero.

Analytical Chemistry↗