USGS ScienceSearch

Geology topics

Gregory L. Stensaas

Publications and source records attributed to Gregory L. Stensaas.

23 records · Page 2Linked to original sources

Geometric quality assessment of lidar data based on swath overlap

This paper provides guidelines on quantifying the relative horizontal and vertical errors observed between conjugate features in the overlapping regions of lidar data. The quantification of these errors is important because their presence quantifies the geometric quality of the data. A data set can be said to have good geometric quality if measurements of identical features, regardless of their position or orientation, yield identical results. Good geometric quality indicates that the data are produced using sensor models that are working as they are mathematically designed, and data acquisition processes are not introducing any unforeseen distortion in the data. High geometric quality also leads to high geolocation accuracy of the data when the data acquisition process includes coupling the sensor with geopositioning systems. Current specifications (e.g. Heidemann 2014) do not provide adequate means to quantitatively measure these errors, even though they are required to be reported. Current accuracy measurement and reporting practices followed in the industry and as recommended by data specification documents also potentially underestimate the inter-swath errors, including the presence of systematic errors in lidar data. Hence they pose a risk to the user in terms of data acceptance (i.e. a higher potential for Type II error indicating risk of accepting potentially unsuitable data). For example, if the overlap area is too small or if the sampled locations are close to the center of overlap, or if the errors are sampled in flat regions when there are residual pitch errors in the data, the resultant Root Mean Square Differences (RMSD) can still be small. To avoid this, the following are suggested to be used as criteria for defining the inter-swath quality of data: a) Median Discrepancy Angle b) Mean and RMSD of Horizontal Errors using DQM measured on sloping surfaces c) RMSD for sampled locations from flat areas (defined as areas with less than 5 degrees of slope) It is suggested that 4000-5000 points are uniformly sampled in the overlapping regions of the point cloud, and depending on the surface roughness, to measure the discrepancy between swaths. Care must be taken to sample only areas of single return points only. Point-to-Plane distance based data quality measures are determined for each sample point. These measurements are used to determine the above mentioned parameters. This paper details the measurements and analysis of measurements required to determine these metrics, i.e. Discrepancy Angle, Mean and RMSD of errors in flat regions and horizontal errors obtained using measurements extracted from sloping regions (slope greater than 10 degrees). The research is a result of an ad-hoc joint working group of the US Geological Survey and the American Society for Photogrammetry and Remote Sensing (ASPRS) Airborne Lidar Committee.

Conference Paper

National Land Imaging Requirements (NLIR) Pilot Project summary report: Summary of moderate resolution imaging user requirements

Under the National Land Imaging Requirements (NLIR) Project, the U.S. Geological Survey (USGS) is developing a functional capability to obtain, characterize, manage, maintain and prioritize all Earth observing (EO) land remote sensing user requirements. The goal is a better understanding of community needs that can be supported with land remote sensing resources, and a means to match needs with appropriate solutions in an effective and efficient way. The NLIR Project is composed of two components. The first component is focused on the development of the Earth Observation Requirements Evaluation System (EORES) to capture, store and analyze user requirements, whereas, the second component is the mechanism and processes to elicit and document the user requirements that will populate the EORES. To develop the second component, the requirements elicitation methodology was exercised and refined through a pilot project conducted from June to September 2013. The pilot project focused specifically on applications and user requirements for moderate resolution imagery (5–120 meter resolution) as the test case for requirements development. The purpose of this summary report is to provide a high-level overview of the requirements elicitation process that was exercised through the pilot project and an early analysis of the moderate resolution imaging user requirements acquired to date to support ongoing USGS sustainable land imaging study needs. The pilot project engaged a limited set of Federal Government users from the operational and research communities and therefore the information captured represents only a subset of all land imaging user requirements. However, based on a comparison of results, trends, and analysis, the pilot captured a strong baseline of typical applications areas and user needs for moderate resolution imagery. Because these results are preliminary and represent only a sample of users and application areas, the information from this report should only be used to indicate general user needs for the applications covered. Users of the information are cautioned that use of specific numeric results may be inappropriate without additional research. Any information used or cited from this report should specifically be cited as preliminary findings.

Open-File Report

ASPRS research on quantifying the geometric quality of lidar data

The ASPRS Lidar Cal/Val (calibration/validation) Working Group led by the US Geological Survey (USGS) to establish “Guidelines on Geometric Accuracy and Quality of Lidar Data” has made excellent progress via regular teleconferences and meetings. The group is focused on identifying data quality metrics and establishing a set of guidelines for quantifying the quality of lidar data. The working group has defined and agreed on lidar Data Quality Measures (DQMs) to be used for this purpose. The DQMs are envisaged as the first ever consistent way of checking lidar data. It is expected that these metrics will be used as standard methods for quantifying the geometric quality of lidar data. The goal of this article is to communicate these developments to the readers and the larger geospatial community and invite them to participate in the process.

Photogrammetric Engineering and Remote Sensing

Evaluation of candidate Landsat Data Gap Sensors

The capabilities of the currently operational Landsat satellites may be lost before the launch of the follow-on Landsat Data Continuity Mission (LDCM), thus producing a gap in the Landsat data record and the National Satellite Land Remote Sensing Data Archive (NSLRSDA). In anticipation of a gap, the Federal agencies responsible for Landsat program management, the National Aeronautics and Space Administration (NASA) and the Department of Interior (DOI) U. S. Geological Survey (USGS), convened a Landsat Data Gap Study Team (LDGST). The study team assessed the basic characteristics of multiple systems and identified sensors aboard the China-Brazil Earth Resources Satellite (CBERS-2) and the Indian Remote Sensing (IRS-P6) ResourceSat-1 satellite as the most promising sources of Landsat-like data. The sensors include the combination of CBERS-2 Infrared Multi-spectral Scanner (IRMSS) and High Resolution Charged Coupled Device (CCD), as well as the IRS-P6 Advanced Wide Field Sensor (AWiFS) and the IRS-P6 Linear Imaging Self Scanning Sensor (LISS-III). The study team concluded that more robust technical evaluations of data and sensor performance are required before gap mitigation strategies can be fully formulated. A technical report is made available that summarizes the results from those evaluations, including the initial data characterization and science utility evaluation. The report can be accessed at http://calval.cr.usgs.gov/LDGST.php.

Conference Paper

Standards and specifications for the calibration and stability of amateur digital cameras for close-range mapping applications

Photogrammetry is concerned with the accurate derivation of spatial and descriptive information from imagery that can be used in several applications such as mapping, DEM generation, orthophoto production, construction planning, environmental monitoring, structural analysis, 3D visualization, and change detection. The type of cameras traditionally used for high accuracy projects were large format analogue cameras. In recent years, however, the use of digital cameras for photogrammetric purposes has become more prevalent. The switch by some users from analogue to digital cameras has been fuelled by the ease of use, decreasing cost, and increasing resolution of digital cameras. Digital photogrammetric cameras can be classified into several categories: line cameras (e.g., ADS40 from Leica Geosystems), large format frame cameras (e.g., DMC TM from Zeiss/Intergraph), and medium to small-format digital cameras. More recently, amateur medium-format digital cameras (MFDC) and small-format digital cameras (SFDC) are being used in photogrammetric activities (e.g., in conjunction with LiDAR systems, smaller flight blocks, and for close-range photogrammetric applications). The continuing development in the capabilities of digital photogrammetry coupled with users’ needs has spawned new markets in photogrammetric mapping with amateur digital cameras. With the wide spectrum of designs for amateur digital cameras, several issues have surfaced, including the method and quality of camera calibration, as well as long-term stability. This paper addresses these concerns and outlines possible solutions. First, we will start by introducing an automated methodology for an in-door camera calibration. The main objective of such a procedure is to provide mapping companies using these cameras with a simple calibration procedure that requires an easy-to-establish test field. The paper will then discuss the concept of how to evaluate camera stability, which will be followed by the introduction of a set of tools for its evaluation. Following the discussion on calibration and stability analysis, the paper will deal with several related questions: How to develop meaningful standards for evaluating the outcome from the calibration procedure; How to develop meaningful standards for evaluating the stability of the involved camera; Is there a flexibility in choosing the stability analysis tool based on the geo-referencing procedure; Can the stability analysis be used for evaluating the equivalency of different distortion models. Finally, experimental results are then provided for two small format digital cameras.

Conference Paper