Heat-flow data and their relation to observed geothermal phenomena near Klamath Falls, Oregon

Two holes were drilled to depths of about 180 m in the Lower Klamath Lake basin south of Klamath Falls, Oregon, to obtain heat flow data and to provide estimates of the thermal conductivity of the valley fill. Twenty-nine thermal conductivity determinations on eight cores give a mean conductivity of 1.82 mcal/cm s °C (0.75 W/m °K). Curvature in the upper 50 m of both terriperature profiles indicates a decrease in surface temperature of about 1.8°C, presumably resulting frorn reclamation of what was marshland in the early part of this century. A surprisingly low heat flow of 0.3 HFU (1 HFU = 10 −6 cal/cm 2 s = 41.8 mW/m 2 ) was measured at site LS near the center of the basin. At site OC-1, 7 km east of LS and 2 km from the Klamath Hills geothermal zone, the heat flow was 1.44 HFU, also a low value in this setting. Temperature profiles in 15 unused water wells in the area had linear gradients ranging from 47° to 170°C/km. The corresponding lower limits of heat flow (conductivities measured at the two heat flow sites being used) range from 0.8 to 3.1 HFU. These variations in heat flow evidently are caused by temperature variations in a convecting system within the near-surface volcanic rocks and do not provide firm constraints on the nature of heat sources at depth.

Journal of Geophysical Research

SHALLOW HYDROTHERMAL SYSTEM AT NEWBERRY VOLCANO, OREGON: A CONCEPTUAL MODEL.

Investigations at Newberry Volcano, Oregon, have resulted in a satisfactory account of the shallow hydrothermal system, but have not indicated the nature of a possible geothermal reservoir. Hot springs in the caldera probably represent the return of circulating meteoric water, warmed at shallow depths by high conductive heat flow and by steam rising from greater depths. Ground-water recharge to the hydrothermal system is at most 250 liters per second, of which about 20 liters per second reappears in the hot springs. Analysis of temperature anomalies in a Geological Survey drillhole indicates that ground-water flow totaling about 125 liters per second could be moving laterally at depths of less than 650 m at the drill site. Refs.

Conference Paper

Lower Ipswich River basin

The lower Ipswich River basin is that part of the Ipswich River drainage basin below the Geological Survey stream-gaging station at South Middleton in northeastern Massachusetts (fig. 1). It includes about 110 square miles between the gaging station at South Middleton and the Atlantic Ocean. This report presents basic data collected as part of an investigation of the geology and ground-water resources of the lower Ipswich River basin, Massachusetts by the U.S. Geological Survey in cooperation with the Massachusetts Department of Public Works. The data have been prepared for release in order to make available to the public basic ground-water data that will be useful in the planning of water-resources development. An earlier Basic-Data Report (Baker and Sammel, 1961) presents data pertaining to ground-water conditions in the upper part of the Ipswich River basin (the Wilmington-Reading area).

Massachusetts