USGS ScienceSearch

Geology topics

Dwight Q. Tanner

Publications and source records attributed to Dwight Q. Tanner.

At least 19 recordsLinked to original sources

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, water year 2012: Quality-assurance data and comparison to water-quality standards

Significant Findings Air is entrained in water as it is flows through the spillways of dams, which causes an increase in the concentration of total dissolved gas in the water downstream from the dams. The elevated concentrations of total dissolved gas can adversely affect fish and other freshwater aquatic life. An analysis of total-dissolved-gas and water-temperature data collected at eight monitoring stations on the lower Columbia River in Oregon and Washington in 2012 indicated the following: During parts of the spill season of April–August 2012, hourly values of total dissolved gas (TDG) were larger than 115-percent saturation for the forebay stations (John Day navigation lock, The Dalles forebay, and Bonneville forebay) and the Camas station. Hourly values of total dissolved gas were larger than 120-percent saturation for the tailwater stations (John Day Dam tailwater, The Dalles tailwater, Cascade Island, and Warrendale). During parts of August and September 2012, hourly water temperatures were greater than 20°C (degrees Celsius) at the eight stations on the lower Columbia River. According to the State of Oregon water-temperature standard, the 7-day average of the daily maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C as a result of human activities. Of the 98 laboratory TDG checks that were performed on instruments after field deployment, all were within ± 0.7-percent saturation. All but 1 of the 83 field checks of TDG sensors with a secondary standard were within ± 1.0-percent saturation after 3–4 weeks of deployment in the river. All 88 of the field checks of barometric pressure were within ±1 millimeter of mercury of a primary standard, and all 85 water-temperature field checks were within ±0.2°C of a secondary standard. For the eight monitoring stations in water year 2012, a total of 97.0 percent of the TDG data were received in real time and were within 1-percent saturation of the expected value on the ba-sis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites. Data received from the Cascade Island site were only 77.8 percent complete because the equipment was destroyed by high water. The other stations ranged from 98.9 to 100.0 percent complete.

Oregon, Washington

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, water year 2011: Quality-assurance data and comparison to water-quality standards

Significant Findings Air is entrained in water as it is flows through the spillways of dams, which causes an increase in the concentration of total dissolved gas in the water downstream from the dams. The elevated concentrations of total dissolved gas can adversely affect fish and other freshwater aquatic life. An analysis of total-dissolved-gas and water-temperature data collected at eight monitoring stations on the lower Columbia River in Oregon and Washington in 2011 indicated the following: During the spill season of April–August 2011, hourly values of total dissolved gas (TDG) were larger than 115-percent saturation for the forebay (John Day navigation lock, The Dalles forebay, and Bonneville forebay) and Camas stations. Hourly values of total dissolved gas were larger than 120-percent saturation for the tailwater stations (John Day Dam tailwater, The Dalles tailwater, Cascade Island, and Warrendale). During parts of August and September 2011, hourly water temperatures were greater than 20°C (degrees Celsius) at the eight stations on the lower Columbia River. According to the State of Oregon water-temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C as a result of human activities. Of the 79 laboratory TDG checks that were performed on instruments after field deployment, all were within ± 0.5-percent saturation and only 2 checks were out of calibration by more than 2 mm of Hg. All but 4 of the 66 field checks of TDG sensors with a secondary standard were within ± 1.0-percent saturation after 3–4 weeks of deployment in the river. All 67 of the field checks of barometric pressure were within ±1 millimeter of mercury of a primary standard, and all 66 water-temperature field checks were within ±0.2°C of a secondary standard. For the eight monitoring stations in water year 2011, a total of 93.5 percent of the TDG data were received in real time and were within 1-percent saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites. Data received from the Cascade Island site were only 34.9% complete because the equipment was destroyed by high water. The other stations ranged from 99.6 to 100 percent complete.

Oregon, Washington

Water-quality data from Upper Klamath and Agency Lakes, Oregon, 2009-10

The U.S. Geological Survey Upper Klamath Lake water-quality monitoring program collected data from multiparameter continuous water-quality monitors, weekly water-quality samples, and meteorological stations during 2009 and 2010 from May through November each year. The results of these measurements and sample analyses, as well as quality-control data for the water-quality samples, are presented in this report for 14 sites on Upper Klamath Lake and 2 sites on Agency Lake. These 2 years of data demonstrate a contrast in the seasonal bloom of the dominant cyanobacterium, Aphanizomenon flos-aquae , that can be related to differences in the measured water quality and meteorological variables. Some of the significant findings from 2009 and 2010 are listed below. * Both 2009 and 2010 were characterized by two cyanobacteria blooms, but the blooms differed in timing and intensity. The first bloom in 2009 peaked in late June and at higher chlorophyll a concentrations at most sites than the first bloom in 2010, which peaked in mid-July. A major decline in the first 2009 bloom occurred in late July and was followed by a second bloom that peaked at most sites in mid-August and persisted through September. The decline of the weaker first bloom in 2010 occurred in early August and was followed by a more substantial second bloom that peaked between late August and early September at most sites. * Dissolved oxygen minima associated with bloom declines occurred approximately 2 weeks earlier in 2009 (mid-July) than in 2010 (early August). pH maxima associated with rapid bloom growth occurred in late June and again in mid-August in 2009 and in mid-July and late August in 2010. * In both years, the maxima for total phosphorus and total nitrogen concentrations coincided with the chlorophyll a maximum. The maxima for dissolved nutrient concentrations (orthophosphate, ammonia, and nitrite plus nitrate) coincided with the declines of the first blooms. * Total particulate carbon, total particulate nitrogen, and total particulate phosphorus concentrations were measured in 2009 only. The ratios of carbon to phosphorus and nitrogen to phosphorus in particulates were the highest of the entire season during the rapid growth phase of the first bloom and were the lowest of the season during the decline of the first bloom. These ratios increased with the onset of the second bloom in that year, but to a lesser degree. * Meteorological data show that 2009 was warmer (particularly in June and July), less windy, and more humid early in the season than 2010. The difference in water temperatures reflected the difference in air temperatures in that the lakes were warmer in 2009 than in 2010 starting in early May, when the sensors were deployed, through most of June. Water temperature peaked at a higher value in 2009, and there were more clear days in June 2009 than in June 2010.

Oregon

Geomorphic response of the Sandy River, Oregon, to removal of Marmot Dam

The October 2007 breaching of a temporary cofferdam constructed during removal of the 15-meter (m)-tall Marmot Dam on the Sandy River, Oregon, triggered a rapid sequence of fluvial responses as ~730,000 cubic meters (m 3 ) of sand and gravel filling the former reservoir became available to a high-gradient river. Using direct measurements of sediment transport, photogrammetry, airborne light detection and ranging (lidar) surveys, and, between transport events, repeat ground surveys of the reservoir reach and channel downstream, we monitored the erosion, transport, and deposition of this sediment in the hours, days, and months following breaching of the cofferdam. Rapid erosion of reservoir sediment led to exceptional suspended-sediment and bedload-sediment transport rates near the dam site, as well as to elevated transport rates at downstream measurement sites in the weeks and months after breaching. Measurements of sediment transport 0.4 kilometers (km) downstream of the dam site during and following breaching show a spike in the transport of fine suspended sediment within minutes after breaching, followed by high rates of suspended-load and bedload transport of sand. Significant transport of gravel bedload past the measurement site did not begin until 18 to 20 hours after breaching. For at least 7 months after breaching, bedload transport rates just below the dam site during high flows remained as much as 10 times above rates measured upstream of the dam site and farther downstream. The elevated sediment load was derived from eroded reservoir sediment, which began eroding when a meters-tall knickpoint migrated about 200 m upstream in the first hour after breaching. Rapid knickpoint migration triggered vertical incision and bank collapse in unconsolidated sand and gravel, leading to rapid channel widening. Over the following days and months, the knickpoint migrated upstream more slowly, simultaneously decreasing in height and becoming less distinct. Within 7 months, the knickpoint had migrated 2 km upstream from the dam site and became a riffle-like feature approximately 1 m high and a few tens of meters long. Knickpoint migration, vertical incision, and lateral erosion evacuated about 15 percent of the initial reservoir volume (125,000 m 3 ) within 60 hours following breaching, and by the end of the high flows in May 2008, about 50 percent of the volume had been evacuated. Large stormflows in November 2008 and January 2009 eroded another 6 percent of the original volume of impounded sediment. Little additional sediment eroded during the remainder of the second year following breaching. The rapid erosion of sediment by the modest flow that accompanied dam breaching was driven mainly by the steep hydraulic gradient associated with the abrupt change of base level and knickpoint formation and was aided by the unconsolidated and cohesionless character of the reservoir sediment. In the ensuing months, transport competence diminished as channel geometry evolved and the river gradient through the reservoir reach diminished. Changes in profile gradient in conjunction with channel coarsening and widening led to a rapid slowing of the rate of reservoir erosion. Sediment transport and deposition were strongly controlled by channel-gradient discontinuities and valley morphology downstream of the dam site. Those influences led to a strong divergence of sand and gravel transport and to deposition of a sediment wedge, as much as 4 m thick, that tapered to the preremoval channel bed 1.3 km downstream of the dam site. After 2 years, that deposit contained about 25 percent of the total volume of sediment eroded from the reservoir. The balance was distributed among pools within the Sandy River gorge, a narrow bedrock canyon extending 2 to 9 km downstream of the dam site, and along the channel farther downstream. A two-fraction sediment budget for the first year following breaching indicates that most of the gravel eroded from the reservoir reach was deposited within the sediment wedge and within the gorge, whereas eroded sand largely passed through the gorge and was broadly dispersed farther downstream. The sequence of transporting flows affected the specific trajectory of reservoir erosion and downstream sediment transport during the 2 years following breaching. However, because the overall erosion was largely a consequence of knickpoint retreat and channel widening, which in the 2 years after removal had affected most of the reservoir reach, it is unlikely that the specific sequence of flows significantly affected the overall outcome. Because the knickpoint had largely passed through the reservoir within 2 years, and the remaining reservoir sediment is mostly isolated high above armored or bedrock banks, it is unlikely that substantial additional sediment from the reservoir site will enter the system unless very large flows occur. Continued channel evolution downstream of the dam site is probable as deposits formed in the first 2 years are episodically mobilized. Below the Sandy River gorge, detection of effects related to release of reservoir sediment is challenging, especially in areas of sand deposition, because of the high background supply of sand in the river and substantial channel dynamism.

Oregon

Initial fluvial response to the removal of Oregon's Marmot Dam

A temporary, 14‐meter‐high earthen cofferdam standing in place of Marmot Dam was breached on 19 October 2007, allowing the 80‐ kilometer‐long Sandy River to flow freely from Mount Hood, Oreg., to the Columbia River for the first time in nearly 100 years. Marmot Dam is one of the largest dams in the western United States (in terms of height and volume of stored sediment) to have been removed in the past 40 years, and its removal exposed approximately 730,000 cubic meters of stored sand and gravel to erosion and transport by the newly energetic mountain river. At the time, its breach represented the greatest release of sediment from any U.S. dam removal. (The March 2008 breaching of Montana's Milltown Dam exposed about 5–10 times as much sediment to potential erosion.)

Oregon

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, water year 2010: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight monitoring stations on the lower Columbia River in Oregon and Washington in 2010. Significant findings from the data include: During the spill season of April through August 2010, hourly values of total dissolved gas (TDG) were occasionally larger than 115-percent saturation for the forebay stations (John Day navigation lock, The Dalles forebay, Bonneville forebay, and Camas). Hourly values of total dissolved gas were occasionally larger than 120-percent saturation for four tailwater stations (John Day Dam tailwater, The Dalles tailwater, Cascade Island, and Warrendale). From late July to late August or early September 2010, hourly water temperatures were greater than 20°C (degrees Celsius) at the eight stations on the lower Columbia River. According to the State of Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C Washington regulations state that the 1-day maximum should not exceed 20°C as a result of human activities. All 105 laboratory checks of the TDG sensors (without the membrane attached) with a certified pressure gage were within ± (plus or minus) 0.5 percent saturation after 3 to 4 weeks of deployment in the river. All but 1 of the 85 in situ field checks of TDG sensors with a secondary standard were within ± 2.0-percent saturation after 3-4 weeks of deployment in the river. All 88 of the field checks of barometric pressure were within ± 1 millimeter of mercury of a primary standard, and all 87 water-temperature field checks were within ± 0.2 ° C of a secondary standard. For the eight monitoring stations in water year 2010, a total of 99.7 percent of the TDG data were received in real time and were within 1-percent saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent stations. Data received from the individual stations ranged from 98.4 to 100.0 percent complete.

Oregon, Washington

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, water year 2009: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight monitoring stations on the lower Columbia River in Oregon and Washington in 2009. Significant findings from the data include: During the spill season of April through August 2009, hourly values of total dissolved gas (TDG) were occasionally larger than 115-percent saturation for the forebay stations (John Day navigation lock, The Dalles forebay, Bonneville forebay, and Camas). Hourly values of total dissolved gas were occasionally larger than 120-percent saturation for two tailwater stations (John Day Dam tailwater and Cascade Island). From mid- to late July to mid-September 2009, water temperatures were greater than 20°C (degrees Celsius) at seven stations on the lower Columbia River. According to the State of Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C as a result of human activities. All 96 laboratory checks of the TDG sensors with a certified pressure gage were within 0.4 percent saturation after 3 to 4 weeks of deployment in the river. All but 2 of the 73 in situ field checks of TDG sensors with a secondary standard were within ± (plus or minus) 1.0-percent saturation after 3-4 weeks of deployment in the river. All 74 of the field checks of barometric pressure were within ±2.0 millimeters of mercury of a secondary standard, and all 65 water-temperature field checks were within ±0.2°C. For the eight monitoring stations in water year 2009, a total of 99.2 percent of the TDG data were received in real time by the USGS satellite downlink and were within 1-percent saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites. Data received from the individual stations ranged from 97.0 to 100.0 percent complete.

Oregon, Washington

Water-Quality Data from Upper Klamath and Agency Lakes, Oregon, 2007-08

Significant Findings The U.S. Geological Survey Upper Klamath Lake water-quality monitoring program collected data from multiparameter continuous water-quality monitors, weekly water-quality samples, and meteorological stations during May-November 2007 and 2008. The results of these measurements and sample analyses are presented in this report for 29 stations on Upper Klamath Lake and 2 stations on Agency Lake, as well as quality-assurance data for the water-quality samples. Some of the significant findings from 2007 and 2008 are listed below. In 2007-08, ammonia concentrations were at or near the detection limit at all stations during the second week in June, after which they began to increase, with peak concentrations occurring from July through November. The concentration of un-ionized ammonia, which can be toxic to aquatic life, first began to increase in mid-June and peaked in July or August at most sites. Concentrations of un-ionized ammonia measured in the Upper Klamath Lake in 2007-08 did not reach concentrations that would have been potentially lethal to suckers. Samples collected for the analysis of dissolved organic carbon (DOC) late in the 2007 season showed no evidence of an increase in DOC subsequent to the breaching of the Williamson River Delta levees on October 30. In 2007-08, the lakewide daily median of dissolved oxygen concentration began to increase in early June, and peaked in mid- to late June. The lakewide daily median pH began to increase from early June and peaked in late June (2007) or early July (2008). Lakewide daily median pH slowly decreased during the rest of both seasons. The 2007 lakewide daily median specific conductance values first peaked on July 1, coincident with a peak in dissolved oxygen concentration and pH, followed by a decrease through mid-July. Specific conductance then remained relatively stable until mid-October when a sharp increase began that continued until the end of the season. Lakewide specific conductance values for 2008 steadily increased through the season to a maximum in late September. Lakewide daily median temperatures in both years began to increase during the beginning of June and peaked in July. These temperatures persisted until late August to early September when a gradual decrease occurred. In 2007-08, water-quality conditions monitored at the Agency Lake northern and southern stations were similar to those in Klamath Lake.

Open-File Report

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2008: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight monitoring stations on the lower Columbia River in Oregon and Washington in 2008. Significant findings from the data include: During the spill season of April through August 2008, hourly values of total-dissolved-gas (TDG) concentration were occasionally larger than 115-percent saturation for the forebay stations (John Day navigation lock, The Dalles forebay, Bonneville forebay, and Camas). Hourly values of TDG concentration were occasionally larger than 120-percent saturation for tailwater stations (John Day tailwater, The Dalles tailwater, and Cascade Island). From late July to September 2008, water temperatures were greater than 20°C (degrees Celsius) at seven stations on the lower Columbia River. According to the State of Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C as a result of human activities. Each of the in situ field checks of TDG sensors with a secondary standard was within ±(plus or minus) 1-percent saturation after 3 to 4 weeks of deployment in the river. All field checks of barometric pressure were within ±2.0 millimeters of mercury of a secondary standard, and water-temperature field checks were all within ±0.2°C. For the eight monitoring stations in water year 2008, an average of 99.6 percent of the TDG data were received in real time by the USGS satellite downlink and were within 1-percent saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent stations. Data received from the individual stations ranged from 98.8 to 100.0 percent complete.

Oregon, Washington

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2007: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight sites on the lower Columbia River in 2007. Significant findings from the data include: From early July to mid-September 2007, water temperatures were above 20°C (degrees Celsius) at each of the eight lower Columbia River sites. According to the Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C due to human activities. Most in-situ field checks of total-dissolved-gas sensors with a secondary standard were within ± (plus or minus) 1% saturation after 3 to 4 weeks of deployment in the river. All of the field checks of barometric pressure were within ±2.5 millimeter of mercury of a secondary standard, and water-temperature field checks were all within ±0.2 °C. For the eight monitoring sites in water year 2007, an average of 99.5% of the total-dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites. Data received from the sites ranged from 97.9% to 100.0% complete.

Lower Columbia River

Water Quality and Algal Data for the North Umpqua River Basin, Oregon, 2005

The upper North Umpqua River Basin has experienced a variety of water-quality problems since at least the early 1990's. Several reaches of the North Umpqua River are listed as water-quality limited under section 303(d) of the Clean Water Act. Diamond Lake, a eutrophic lake that is an important source of water and nutrients to the upper North Umpqua River, is also listed as a water-quality limited waterbody (pH, nuisance algae). A draft Total Maximum Daily Load (TMDL) was proposed for various parameters and is expected to be adopted in full in 2006. Diamond Lake has supported potentially toxic blue-green algae blooms since 2001 that have resulted in closures to recreational water contact and impacts to the local economy. Increased populations of the invasive tui chub fish are reportedly responsible, because they feed on zooplankton that would otherwise control the algal blooms. The Final Environmental Impact Statement (FEIS) for the Diamond Lake Restoration Project advocates reduced fish biomass in Diamond Lake in 2006 as the preferred alternative. A restoration project scheduled to reduce fish biomass for the lake includes a significant water-level drawdown that began in January 2006. After the drawdown of Diamond Lake, the fish toxicant rotenone was applied to eradicate the tui chub. The lake will be refilled and restocked with game fish in 2007. Winter exports of nutrients from Diamond Lake during the restoration project could affect the summer trophic status of the North Umpqua River if retention and recycling in Lemolo Lake are significant. The FEIS includes comprehensive monitoring to assess the water quality of the restored Diamond Lake and the effects of that restoration downstream. One component of the monitoring is the collection of baseline data, in order to observe changes in the river's water quality and algal conditions resulting from the restoration of Diamond Lake. During July 2005, the USGS, in cooperation with Douglas County, performed a synoptic survey of water quality and algal conditions, the results of which can be used for comparison with post-restoration conditions in the river as well as with those documented in an earlier study in 1995. This report presents data from that survey.

Oregon

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2006: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have ad-verse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas concentration and water-temperature data at eight stations on the lower Columbia River in 2006. Significant findings from the data include: Variances to the Oregon and Washington water-quality standards for total dissolved gas were exceeded at all of the monitoring stations: Cascade Island (67 days), Camas (60 days), Bonneville forebay (51 days), The Dalles forebay (36 days), John Day tailwater (35 days), John Day navigation lock (20 days), The Dalles tailwater (8 days), and Warrendale (4 days). From early July to the end of August 2006, water temperatures were above 20°C (degrees Celsius) at each of the eight lower Columbia River stations. According to the Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C due to human activities. Most field checks of total-dissolved-gas sensors with a secondary standard were within ± (plus or minus) 1% saturation. All of the field checks of barometric pressure were within ±1 millimeter of mercury of a secondary standard, and water temperature field checks were all within ±0.2°C. For the eight monitoring stations in water year 2006, an average of 99.1% of the total-dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent stations.

Oregon, Washington

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2005: quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight sites on the lower Columbia River in 2005. Significant findings from the data include: Variances to the Oregon and Washington water-quality standards for total dissolved gas were exceeded at five of the monitoring sites: Camas (11 days), John Day tailwater (3 days), The Dalles forebay (3 days), Bonneville forebay (3 days), and John Day navigation lock (1 day). From mid-July to early September, water temperatures were above 20°C (degrees Celsius) at each of the eight lower Columbia River sites. According to the Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C due to human activities. Most field checks of total-dissolved-gas sensors with a secondary standard were within ± (plus or minus) 1% saturation. Most of the field checks of barometric pressure were within ±1 millimeter of mercury of a secondary standard, and water temperature field checks were all within ±0.2°C. For the eight monitoring sites in water year 2005, an average of 98.2% of the total-dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites.

Oregon, Washington

Total dissolved gas and water temperature in the lower Columbia river, Oregon and Washington, 2004: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of total dissolved gas. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers (USACE), collected total-dissolved-gas (TDG) and water-temperature data at eight sites on the lower Columbia River in 2004. Significant findings from the data include: Variances to the Oregon and Washington water-quality standards for total dissolved gas were exceeded on a few days at three of the monitoring sites: Camas, The Dalles forebay, and Bonneville forebay. These exceedances may have been the result of the cumulative effects of supersaturated water moving downstream through the lower Columbia River. Apparently, the levels of TDG did not dissipate rapidly enough downstream from the dams before reaching the next site. TDG levels at an experimental monitoring site directly below Bonneville Dam at Cascade Island showed a larger response to spill than the site 5.5 miles farther downstream at Warrendale. From mid-July to mid-September, water temperatures were above 20°C (degrees Celsius) at each of the seven lower Columbia River sites. Both the Oregon and Washington water-quality standards contain a numerical standard of 20°C for the lower Columbia River. The new location of the forebay monitoring site at John Day navigation lock showed less daily temperature variation than the previous location. The probe at the new site was farther away from the dam and at a greater depth, so it apparently avoided the daily temperature excursions associated with the surface-layer heating at the previous site. Most field checks of total-dissolved-gas sensors with a secondary standard were within ±1% saturation. Most of the field checks of barometric pressure were within ±1 mm Hg (millimeter of mercury) of a secondary standard, and water temperature field checks were all within ±0.1°C. For the seven monitoring sites used to regulate spill in water year 2004, an average of 99.0% of the total- dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites.

Oregon, Washington

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2003: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the concentration of total dissolved gas. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected total- dissolved-gas and water-temperature data at seven sites on the lower Columbia River in 2003. Significant findings from the data include: For the seven monitoring sites in water year 2003, an average of 98.9% of the total-dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites. Most field checks of total-dissolved-gas sensors with a secondary standard were within plus or minus 1% saturation. Field checks of barometric pressure and water temperature were usually within plus or minus 1 millimeter of mercury and plus or minus 0.1 degree Celsius, respectively. The variances to the States of Oregon and Washington water-quality standards for total dissolved gas were exceeded at six of the seven monitoring sites. The sites at Camas and Bonneville forebay had the most days exceeding the variance of 115% saturation. The forebay exceedances may have been the result of the cumulative effects of supersaturated water moving downstream through the lower Columbia River. Apparently, the levels of total dissolved gas did not decrease rapidly enough downstream from the dams before reaching the next site. From mid-July to mid-September, water temperatures were usually above 20 degrees Celsius at each of the seven lower Columbia River sites. According to the Oregon water-quality standard, when the temperature of the lower Columbia River exceeds 20 degrees Celsius, no measurable temperature increase resulting from anthropogenic activities is allowed. Transient increases of about 1 degree Celsius were noted at the John Day forebay site, due to localized solar heating.

Oregon, Washington

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2002: Quality-assurance data and comparison to water-quality standards

Significant Findings The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected total-dissolved-gas and water-temperature data at eight sites near dams on the lower Columbia River in 2002. When water is released through the spillways of dams, air is entrained in the water, increasing the concentration of total dissolved gas to levels that can have adverse effects on freshwater aquatic life. Significant findings include: For the eight monitoring sites in water year 2002, an average of 99.6% of the total-dissolved gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data and ambient river conditions at adjacent sites. Most field checks of total-dissolved-gas sensors with a secondary standard were within 1% saturation. Field checks of barometric pressure and water temperature were usually within 1 millimeter of mercury and 0.05 degrees Celsius, respectively. In June and July 2002, spills exceeded 140,000 cubic feet per second at the John Day, The Dalles, and Bonneville Dams. These spills resulted in levels of total dissolved gas that exceeded 120% saturation downstream of the dams. The variance to the State of Oregon water-quality standard for total dissolved gas of 110% saturation was exceeded at seven of the eight monitoring sites. The sites at Camas and Bonneville are considered forebay sites and had the most days exceeding the variance of 115% saturation. The forebay exceedances may have been the result of the cumulative effects of significant spill throughout the lower Columbia River. Apparently, the levels of total dissolved gas did not dissipate rapidly enough downstream of the dams before reaching the next site. From mid-July to mid-September, water temperatures were usually above 20 degrees Celsius at each of the seven lower Columbia River sites in operation. According to the Oregon water-quality standard, when the temperature of the lower Columbia River exceeds 20 degrees Celsius, no measurable temperature increase resulting from anthropogenic activities is allowed.

Oregon, Washington

Selected elements and organic chemicals in streambed sediment in the Salem area, Oregon, 1999

Analysis of streambed sediments in the Salem, Oregon, area showed anomalously large concentrations of some elements and organic chemicals, indicating contamination from anthropogenic and/or geologic sources. The streambed sediment sample from Clark Creek, an urban basin, had large concentrations of polycyclic aromatic hyrdocarbons (PAHs), organochlorines, cadmium, lead, and zinc. The sample from the East Fork of Pringle Creek, which is a mostly urban basin, had the highest concentrations of DDD, DDE, and DDT compounds. Aldrin was detected in streambed sediment at only one site, the East Fork of Pringle Creek. Ten of the 14 sites sampled had exceedances of the sediment quality guidelines of the Canadian Council of Ministers of the Environment (CCME), and 8 sites had exceedances of guidelines from the Puget Sound Dredged Disposal Analysis (PSDDA) Program. Trace element concentrations in the Salem area generally were similar to those found previously in the Willamette Basin and nationally. However, cadmium, lead, and zinc concentrations were larger in the sample from Clark Creek than for largest value for Willamette Basin data from earlier studies. Zinc concentrations in the sample from Clark Creek exceeded sediment quality guidelines from the CCME and PSDDA. p,p'-DDE, which is a persistent breakdown product of the banned organochlorine-insecticide, DDT, was detected at all sites. Total DDT (the sum of p,p'-DDD, p,p'-DDE, and p,p'-DDT) concentrations exceeded the PSDDA screening level at eight sites and exceeded twice the PSDDA maximum level at the East Fork of Pringle Creek. Cis- and trans- chlordanes were detected at about 80% of the sites. The concentration of total chlordane for the sample at Clark Creek was larger than for any sample from previous Willamette Basin studies. The largest concentration of dieldrin also was from the sample at Clark Creek, which was the only site that exceeded the CCME guideline for dieldrin. The high levels of contaminants in some Salem area streams indicates the need for further study to assess the biological effects of these contaminants. Future monitoring in the Salem area could include bioassays using benthic invertebrates and the measurement of organochlorine compounds, including DDT, DDE, DDD, and dieldrin in fish tissue. Because resident fish may be consumed by humans and wildlife, fish tissue analyses would be helpful to determine the health risk associated with fish consumption.

Water-Resources Investigations Report

Quality-assurance data, comparison to water-quality standards, and site considerations for total dissolved gas and water temperature, lower Columbia River, Oregon and Washington, 2001

Significant Findings For eight monitoring sites, in water year 2001, an average of 99.3% of the total-dissolved-gas data were received in real time and passed quality-assurance checks. After 2 to 3 weeks of deployment in the river, most comparisons of field total-dissolved-gas sensors with a secondary standard (another calibrated total-dissolved-gas sensor) were within 1%. The only exceedances of Oregon water-quality standards for total dissolved gas occurred on May 23 and 24, 2001, at the Camas, Washington, station. At the forebay of the John Day Dam, temporary increases in water temperature and total dissolved gas occurred on hot afternoons during periods of low wind. These increases were not observed at the John Day tailwater station. At Camas, Washington, daily variations of total dissolved gas were probably due to the production of oxygen by aquatic plants and to water-temperature variations on warm, sunny days. During spill over Bonneville Dam in water year 2001, the site on the Oregon side of the Columbia River, Warrendale, measured larger total-dissolved-gas levels than the site directly across on the Washington side at Skamania. Apparently, streamflow through generating facilities on the north side of the dam forced supersaturated water from the spill bays over to the Oregon side of the river. At times in July and August 2001, the total-dissolved-gas probe at Warrendale could not be positioned below the minimum compensation depth because the river was too shallow at that location. Consequently, degassing at probe depth may have occurred, and total dissolved gas may have been larger in locations with greater depths.

Oregon, Washington