USGS ScienceSearch

Geology topics

D. Sweetkind

Publications and source records attributed to D. Sweetkind.

2 recordsLinked to original sources

Hydrologic models of modern and fossil geothermal systems in the Great Basin: Genetic implications for epithermal Au-Ag and Carlin-type gold deposits

The Great Basin region in the western United States contains active geothermal systems, large epithermal Au-Ag deposits, and world-class Carlin-type gold deposits. Temperature profiles, fluid inclusion studies, and isotopic evidence suggest that modern and fossil hydrothermal systems associated with gold mineralization share many common features, including the absence of a clear magmatic fluid source, discharge areas restricted to fault zones, and remarkably high temperatures (>200 ??C) at shallow depths (200-1500 m). While the plumbing of these systems varies, geochemical and isotopic data collected at the Dixie Valley and Beowawe geothermal systems suggest that fluid circulation along fault zones was relatively deep (>5 km) and comprised of relatively unexchanged Pleistocene meteoric water with small (<2.5%) shifts from the meteoric water line (MWL). Many fossil ore-forming systems were also dominated by meteoric water, but usually exhibit ??18O fluid-rock interactions with larger shifts of 5???-20??? from the MWL. Here we present a suite of two-dimensional regional (100 km) and local (40-50 km) scale hydrologic models that we have used to study the plumbing of modern and Tertiary hydrothermal systems of the Great Basin. Geologically and geophysically consistent cross sections were used to generate somewhat idealized hydrogeologic models for these systems that include the most important faults, aquifers, and confining units in their approximate configurations. Multiple constraints were used, including enthalpy, ??18O, silica compositions of fluids and/or rocks, groundwater residence times, fluid inclusion homogenization temperatures, and apatite fission track anomalies. Our results suggest that these hydrothermal systems were driven by natural thermal convection along anisotropic, subvertical faults connected in many cases at depth by permeable aquifers within favorable lithostratigraphic horizons. Those with minimal fluid ?? 18O shifts are restricted to high-permeability fault zones and relatively small-scale (???5 km), single-pass flow systems (e.g., Beowawe). Those with intermediate to large isotopic shifts (e.g., epithermal and Carlin-type Au) had larger-scale (???15 km) loop convection cells with a greater component of flow through marine sedimentary rocks at lower water/rock ratios and greater endowments of gold. Enthalpy calculations constrain the duration of Carlin-type gold systems to probably <200 k.y. Shallow heat flow gradients and fluid silica concentrations suggest that the duration of the modern Beowawe system is <5 k.y. However, fluid flow at Beowawe during the Quaternary must have been episodic with a net duration of ???200 k.y. to account for the amount of silica in the sinter deposits. In the Carlin trend, fluid circulation extended down into Paleozoic siliciclastic rocks, which afforded more mixing with isotopically enriched higher enthalpy fluids. Computed fission track ages along the Carlin trend included the convective effects, and ranged between 91.6 and 35.3 Ma. Older fission track ages occurred in zones of groundwater recharge, and the younger ages occurred in discharge areas. This is largely consistent with fission track ages reported in recent studies. We found that either an amagmatic system with more permeable faults (10-11 m2) or a magmatic system with less permeable faults (10-13 m2) could account for the published isotopic and thermal data along the Carlin trend systems. Localized high heat flow beneath the Muleshoe fault was needed to match fl uid inclusion temperatures at Mule Canyon. However, both magmatic and amagmatic scenarios require the existence of deep, permeable faults to bring hot fluids to the near surface. ?? 2008 Geological Society of America.

Geosphere

Preliminary model of the pre-Tertiary basement rocks beneath Yucca Flat, Nevada Test Site, Nevada, based on analysis of gravity and magnetic data

The Environmental Restoration Program of the U.S. Department of Energy, Nevada Operations Office, was developed to investigate the possible consequences to the environment of 40 years of nuclear testing on the Nevada Test Site. The majority of the tests were detonated underground, introducing contaminants into the ground-water system (Laczniak and others, 1996). An understanding of the ground-water flow paths is necessary to evaluate the extent of ground-water contamination. This report provides information specific to Yucca Flat on the Nevada Test Site. Critical to understanding the ground-water flow beneath Yucca Flat is an understanding of the subsurface geology, particularly the structure and distribution of the pre-Tertiary rocks, which comprise both the major regional aquifer and aquitard sequences (Winograd and Thordarson, 1975; Laczniak and others, 1996). Because the pre-Tertiary rocks are not exposed at the surface of Yucca Flat their distribution must be determined through well logs and less direct geophysical methods such as potential field studies. In previous studies (Phelps and others, 1999; Phelps and Mckee, 1999) developed a model of the basement surface of the Paleozoic rocks beneath Yucca Flat and a series of normal faults that create topographic relief on the basement surface. In this study the basement rocks and structure of Yucca Flat are examined in more detail using the basement gravity anomaly derived from the isostatic gravity inversion model of Phelps and others (1999) and high-resolution magnetic data, as part of an effort to gain a better understanding of the Paleozoic rocks beneath Yucca Flat in support of groundwater modeling.

Nevada