USGS ScienceSearch

Geology topics

Carolyn M. Koebel

Publications and source records attributed to Carolyn M. Koebel.

4 recordsLinked to original sources

Vibration monitoring results near a bat hibernaculum at Mammoth Cave National Park, Kentucky, March 2016

Vibrations originating from construction of a new walkway in a passage of Mammoth Cave, from walking personnel simulating a bat survey, and from ambient sources were measured near a bat hibernaculum beneath Mammoth Cave National Park, Kentucky, to determine if the vibrations were disturbing the hibernating bats. Data presented indicate direction and magnitude of the vibrations. The seven sources of vibration that were recorded include hammer drill (one location), plate compactor (two locations), jackhammer (two locations), personnel simulating a bat survey near the hibernaculum (walking throughout the cave), and background levels. Vibrations were measured for approximately 10 seconds during each triggering of the source and each source was recorded 5–10 times to represent the reproducibility of the vibrations. The plate compactor produced the largest velocity of 0.00226 inch per second on one of the longitudinal components. The simulated bat survey produced the largest value of acceleration of 0.34 inch per square second in the vertical component. Maximum vertical velocities and accelerations did not exceed literature values for human perception or visible agitation in laboratory mice.

Kentucky

Water pressure and ground vibrations induced by water guns near Brandon Road Lock and Dam and Lemont, Illinois

Multiple geophysical sensors were used to characterize the underwater pressure field and ground vibrations of a seismic water gun and its suitability to deter the movement of Asian carps (particularly the silver [ Hypophthalmichthys molitrix ] and bighead [ Hypophthalmichthys nobilis ] carps) while ensuring the integrity of surrounding structures. The sensors used to collect this information were blast-rated hydrophones, surface- and borehole-mounted geophones, and fixed accelerometers. Results from two separate studies are discussed in this report. The Brandon Road study took place in May 2014, in the Des Plaines River, in a concrete-walled channel downstream of the Brandon Road Lock and Dam near Joliet, Illinois. The Lemont study took place in June 2014, in a segment of the dolomite setblock-lined Chicago Sanitary and Ship Canal near Lemont, Illinois. Two criteria were evaluated to assess the potential deterrence to carp migration, and to minimize the expected effect on nearby structures from discharge of the seismic water gun. The first criterion was a 5-pound-per-square-inch (lb/in 2 ) limit for dynamic underwater pressure variations. The second criterion was a maximum velocity and acceleration disturbance of 0.75 inch per second (in/s) for sensitive machinery (such as the lock gates and pumps) and 2.0 in/s adjacent to canal walls, respectively. The criteria were based on previous studies of fish responses to dynamic pressure variations, and effects of vibrations on the structural integrity of concrete walls. The Brandon Road study evaluated the magnitude and extent of the pressure field created by two water gun configurations in the concrete-walled channel downstream of the lock where channel depths ranged from 11 to 14 feet (ft). Data from a single 80-cubic-inch (in³) water gun set at 6 ft below water surface (bws) produced a roughly cylindrical 5-lb/in 2 pressure field 20 ft in radius, oriented vertically, with the radius decreasing to less than 15 ft at the water surface. A combination of two 80-in 3 water guns set at 6 and 8 ft, respectively, produced a similarly shaped 5 lb/in 2 pressure field 30 ft in radius. Neither of the water gun configurations exceeded the given threshold of 5 lb/in 2 above the static pressure along the walls of the canal at the 700 lb/in 2 water gun input pressure. Velocity and acceleration data were collected simultaneously with the underwater pressure data to understand the response of adjacent canal walls to the water gun firings. Maximum velocity and acceleration were 0.239 in/s and 0.0188 feet per second squared (ft/s 2 ), respectively. The Lemont study replicated and expanded upon work done in 2011. The pressure field created by the water gun was evaluated in a deeper environment (about 25 ft of water depth) than that of the Brandon Road study. To replicate the 2011 study, data were collected with the same water gun placements and input pressure, but static underwater pressure monitoring was added. Two 80-in 3 water guns were suspended below a platform at depths of 4 and 14 ft bws. Pressure was lower when the gun suspended at 4 ft bws was fired as compared to firing the single gun suspended at 14 ft bws. Firing both guns simultaneously produced similar pressures to the single gun suspended at 14 ft bws. Data were collected to assess the pressure field produced by two 80-in 3 water guns separated by 80 ft and suspended at a depth of 14 ft bws. The spatial extent of the 5-lb/in 2 threshold varied substantially with gun input air pressure. Firing the water gun with an air pressure of 2,000 lb/in 2 generated a pressure field greater than the threshold at all but one location in the measured region. Additionally, the water gun with an air pressure of 1,000 lb/in 2 did not reach the threshold anywhere in the measured region. Maximum velocity and acceleration were 0.304 in/s and 0.015 ft/s 2 , respectively.

Illinois

Field evaluation of carbon dioxide as a fish deterrent at a water management structure along the Illinois River

Construction of a water management structure (WMS) in the levee surrounding The Nature Conservancy’s Emiquon Preserve (Havana, Illinois, USA) created a new hydrological connection and potential aquatic invasive species pathway between the Illinois River and a large conservation wetland complex. Site managers need a control tool that deters the upstream passage of non-native fishes into the wetland lakes, but does not interfere with normal gate operation and water discharge. This short field study evaluated carbon dioxide (CO 2 ) injected into water as a non-obstructive method to reduce fish abundance near the WMS culverts. We quantified relative fish abundance using underwater sonar with and without injection of CO 2 into culverts during three discharge events: no flow (0 m 3 /s), restricted flow (0.9 m 3 /s), and unrestricted flow (3.2 m 3 /s). Overall, CO 2 reached or exceeded our target concentration of 100 mg/L during no flow and restricted flow, and fish abundance was 70–95% lower at culvert entrances relative to untreated control days. The target CO 2 level was not reached during unrestricted flow and fish abundance was not reduced during CO 2 injection. Atmospheric CO 2 concentrations were inconsequential and unaffected by CO 2 treatments throughout testing. Results from this initial field study provide several considerations for CO 2 as a fish deterrent in natural environments.

Illinois

Water pressure and ground vibrations induced by water guns at a backwater pond on the Illinois River near Morris, Illinois

Three different geophysical sensor types were used to characterize the underwater pressure waves and ground velocities generated by the underwater firing of seismic water guns. These studies evaluated the use of water guns as a tool to alter the movement of Asian carp. Asian carp are aquatic invasive species that threaten to move into the Great Lakes Basin from the Mississippi River Basin. Previous studies have identified a threshold of approximately 5 pounds per square inch (lb/in 2 ) for behavioral modification and for structural limitation of a water gun barrier. Two studies were completed during August 2014 and May 2015 in a backwater pond connected to the Illinois River at a sand and gravel quarry near Morris, Illinois. The August 2014 study evaluated the performance of two 80-cubic-inch (in 3 ) water guns. Data from the 80-in 3 water guns showed that the pressure field had the highest pressures and greatest extent of the 5-lb/in 2 target value at a depth of 5 feet (ft). The maximum recorded pressure was 13.7 lb/in 2 , approximately 25 ft from the guns. The produced pressure field took the shape of a north-south-oriented elongated sphere with the 5-lb/in 2 target value extending across the entire study area at a depth of 5 ft. Ground velocities were consistent over time, at 0.0067 inches per second (in/s) in the transverse direction, 0.031 in/s in the longitudinal direction, and 0.013 in/s in the vertical direction. The May 2015 study evaluated the performance of one and two 100-in 3 water guns. Data from the 100-in 3 water guns, fired both individually and simultaneously, showed that the pressure field had the highest pressures and greatest extent of the 5-lb/in 2 target value at a depth of 5 ft. The maximum pressure was 57.4 lb/in 2 , recorded at the underwater blast sensor closest to the water guns (at a horizontal distance of approximately 3 ft), as two guns fired simultaneously. Pressures and extent of the 5-lb/in 2 target value decrease above and below this 5-ft depth, producing a relatively north-south-oriented pressure field shaped like an elongated sphere.

Illinois