USGS Science⌕ Search

Geology topics

C.F. Williams

Publications and source records attributed to C.F. Williams.

15 recordsLinked to original sources

Controls on deep direct-use thermal energy storage (DDU-TES) in the Portland Basin, Oregon, USA

Aquifer Thermal Energy Storage is being evaluated as a complementary technology to Deep Direct-Use for the Portland Basin, Oregon, USA. Aquifers can be used to efficiently distribute and store heat for seasonal use. The use of injection-extraction well pairs precludes the need to store or dispose of large volumes of pumped groundwater or to obtain a consumptive groundwater right. Injection temperatures vary seasonally, and well pairs can operate in continuous (single direction of flow) or cyclic (seasonal reversal of flow) modes. The target injection aquifers are the lowest Columbia River Basalt Group interflow zones, which are thermally and hydraulically separated from the overlying aquifer system, minimizing heat loss. A new aquifer thermal energy storage design tool allows assessment of thermal storage and recovery using: (1) system design parameters (e.g., well spacing and pumping rate), (2) thermal and hydraulic property values, and (3) regional groundwater flow rates. In continuous mode, extracted water temperature trends towards the flow-weighted average temperature of injected water over time, with the injected signal significantly lagged and damped. By controlling well spacing and temperature of delivered water (possibly using supplemental heating) continuous mode provides steady reliable warm water to end-users year-round. In cyclic mode, there is an advectively and conductively heated zone near the hot well and a cooled zone near the cool well, with temperatures substantially above and below the flow-weighted average injection temperature, respectively. In cyclic mode, during extraction, water temperatures start high or low, depending on the well, and temperatures trend towards the average injection temperature over the season. For the Columbia River Basalt Group in the Portland Basin, the quantity and quality of heat delivered depends most strongly on operational schedule, well spacing, mode of operation, and heterogeneity of the injection horizon.

Oregon↗

The thermal regime in the resurgent dome of Long Valley Caldera, California: Inferences from precision temperature logs in deep wells

Long Valley Caldera in eastern California formed 0.76Ma ago in a cataclysmic eruption that resulted in the deposition of 600km3 of Bishop Tuff. The total current heat flow from the caldera floor is estimated to be ~290MW, and a geothermal power plant in Casa Diablo on the flanks of the resurgent dome (RD) generates ~40MWe. The RD in the center of the caldera was uplifted by ~80cm between 1980 and 1999 and was explained by most models as a response to magma intrusion into the shallow crust. This unrest has led to extensive research on geothermal resources and volcanic hazards in the caldera. Here we present results from precise, high-resolution, temperature-depth profiles in five deep boreholes (327-1,158m) on the RD to assess its thermal state, and more specifically 1) to provide bounds on the advective heat transport as a guide for future geothermal exploration, 2) to provide constraints on the occurrence of magma at shallow crustal depths, and 3) to provide a baseline for future transient thermal phenomena in response to large earthquakes, volcanic activity, or geothermal production. The temperature profiles display substantial non-linearity within each profile and variability between the different profiles. All profiles display significant temperature reversals with depth and temperature gradients <50??C/km at their bottom. The maximum temperature in the individual boreholes ranges between 124.7??C and 129.5??C and bottom hole temperatures range between 99.4??C and 129.5??C. The high-temperature units in the three Fumarole Valley boreholes are at the approximate same elevation as the high-temperature unit in borehole M-1 in Casa Diablo indicating lateral or sub-lateral hydrothermal flow through the resurgent dome. Small differences in temperature between measurements in consecutive years in three of the wells suggest slow cooling of the shallow hydrothermal flow system. By matching theoretical curves to segments of the measured temperature profiles, we calculate horizontal groundwater velocities in the hydrothermal flow unit under the RD that range from 1.9 to 2.8m/yr, which corresponds to a maximum power flowing through the RD of 3-4MW. The relatively low temperatures and large isothermal segments at the bottom of the temperature profiles are inconsistent with the presence of magma at shallow crustal levels. ?? 2010.

Journal of Volcanology and Geothermal Research↗

Putting it all together: Exhumation histories from a formal combination of heat flow and a suite of thermochronometers

A suite of new techniques in thermochronometry allow analysis of the thermal history of a sample over a broad range of temperature sensitivities. New analysis tools must be developed that fully and formally integrate these techniques, allowing a single geologic interpretation of the rate and timing of exhumation and burial events consistent with all data. We integrate a thermal model of burial and exhumation, (U-Th)/He age modeling, and fission track age and length modeling. We then use a genetic algorithm to efficiently explore possible time-exhumation histories of a vertical sample profile (such as a borehole), simultaneously solving for exhumation and burial rates as well as changes in background heat flow. We formally combine all data in a rigorous statistical fashion. By parameterizing the model in terms of exhumation rather than time-temperature paths (as traditionally done in fission track modeling), we can ensure that exhumation histories result in a sedimentary basin whose thickness is consistent with the observed basin, a physically based constraint that eliminates otherwise acceptable thermal histories. We apply the technique to heat flow and thermochronometry data from the 2.1 -km-deep San Andreas Fault Observatory at Depth pilot hole near the San Andreas fault, California. We find that the site experienced <1 km of exhumation or burial since the onset of San Andreas fault activity

Journal of Geophysical Research B: Solid Earth↗

The USGS national geothermal resource assessment: An update

The U. S. Geological Survey (USGS) is working with the Department of Energy's (DOE) Geothermal Technologies Program and other geothermal organizations on a three-year effort to produce an updated assessment of available geothermal resources. The new assessment will introduce significant changes in the models for geothermal energy recovery factors, estimates of reservoir volumes, and limits to temperatures and depths for electric power production. It will also include the potential impact of evolving Enhanced Geothermal Systems (EGS) technology. An important focus in the assessment project is on the development of geothermal resource models consistent with the production histories and observed characteristics of exploited geothermal fields. New models for the recovery of heat from heterogeneous, fractured reservoirs provide a physically realistic basis for evaluating the production potential of both natural geothermal reservoirs and reservoirs that may be created through the application of EGS technology. Project investigators have also made substantial progress studying geothermal systems and the factors responsible for their formation through studies in the Great Basin-Modoc Plateau region, Coso, Long Valley, the Imperial Valley and central Alaska, Project personnel are also entering the supporting data and resulting analyses into geospatial databases that will be produced as part of the resource assessment.

Conference Paper↗

Frictional strength heterogeneity and surface heat flow: Implications for the strength of the creeping San Andreas fault

Heat flow measurements along much of the San Andreas fault (SAF) constrain the apparent coefficient of friction (??app) of the fault to <0.2, much lower than laboratory-derived friction values for most geologic materials. However, heat flow data are sparse near the creeping section of the SAF, a frictional "asperity" where the fault slips almost exclusively by aseismic creep. We test the hypothesis that the creeping section has a substantially higher or lower ?? app than adjacent sections of the SAF. We use numerical models to explore the effects of faults with spatially and temporally heterogeneous frictional strength on the spatial distribution of surface heat flow. Heat flow from finite length asperities is uniformly lower than predicted by assuming an infinitely long fault. Over geologic time, lateral offset from strike-slip faulting produces heat flow patterns that are asymmetric across the fault and along strike. We explore a range of asperity sizes, slip rates, and displacement histories for comparing predicted spatial patterns of heat flow with existing measurements. Models with ??app ??? 0.1 fit the data best. For most scenarios, heat flow anomalies from a frictional asperity with ??app > 0.2 should be detectable even with the sparse existing observations, implying that ??app for the creeping section is as low as the surrounding SAF. Because the creeping section does not slip in large earthquakes, the mechanism controlling its weakness is not related to dynamic processes resulting from high slip rate earthquake ruptures. Copyright 2006 by the American Geophysical Union.

Journal of Geophysical Research B: Solid Earth↗

Prediction and discovery of new geothermal resources in the Great Basin: Multiple evidence of a large undiscovered resource base

Geothermal potential maps by themselves cannot directly be used to estimate undiscovered resources. To address the undiscovered resource base in the Great Basin, a new and relatively quantitative methodology is presented. The methodology involves three steps, the first being the construction of a data-driven probabilistic model of the location of known geothermal systems using weights of evidence. The second step is the construction of a degree-of-exploration model. This degree-of-exploration model uses expert judgment in a fuzzy logic context to estimate how well each spot in the state has been explored, using as constraints digital maps of the depth to the water table, presence of the carbonate aquifer, and the location, depth, and type of drill-holes. Finally, the exploration model and the data-driven occurrence model are combined together quantitatively using area-weighted modifications to the weights-of-evidence equations. Using this methodology in the state of Nevada, the number of undiscovered geothermal systems with reservoir temperatures ???100??C is estimated at 157, which is 3.2 times greater than the 69 known systems. Currently, nine of the 69 known systems are producing electricity. If it is conservatively assumed that an additional nine for a total of 18 of the known systems will eventually produce electricity, then the model predicts 59 known and undiscovered geothermal systems are capable of producing electricity under current economic conditions in the state, a figure that is more than six times higher than the current number. Many additional geothermal systems could potentially become economic under improved economic conditions or with improved methods of reservoir stimulation (Enhanced Geothermal Systems).This large predicted geothermal resource base appears corroborated by recent grass-roots geothermal discoveries in the state of Nevada. At least two and possibly three newly recognized geothermal systems with estimated reservoir temperatures ???150??C have been identified on the Pyramid Lake Paiute Reservation in west-central Nevada. Evidence of three blind geothermal systems has recently been uncovered near the borate-bearing playas at Rhodes, Teels, and Columbus Marshes in southwestern Nevada. Recent gold exploration drilling has resulted in at least four new geothermal discoveries, including the McGinness Hills geothermal system with an estimated reservoir temperature of roughly 200??C. All of this evidence suggests that the potential for expansion of geothermal power production in Nevada is significant.

Conference Paper↗

Outstanding issues for new geothermal resource assessments

A critical question for the future energy policy of the United States is the extent to which geothermal resources can contribute to an ever-increasing demand for electricity. Electric power production from geothermal sources exceeds that from wind and solar combined, yet the installed capacity falls far short of the geothermal resource base characterized in past assessments, even though the estimated size of the resource in six assessments completed in the past 35 years varies by thousands of Megawatts-electrical (MWe). The U. S. Geological Survey (USGS) is working closely with the Department of Energy's (DOE) Geothermal Research Program and other geothermal organizations on a three-year effort to produce an updated assessment of available geothermal resources. The new assessment will introduce significant changes in the models for geothermal energy recovery factors, estimates of reservoir permeability, limits to temperatures and depths for electric power production, and include the potential impact of evolving Enhanced (or Engineered) Geothermal Systems (EGS) technology.

Conference Paper↗

Heat flow in the SAFOD pilot hole and implications for the strength of the San Andreas Fault

Detailed thermal measurements have been acquired in the 2.2-km-deep SAFOD pilot hole, located 1.8 km west of the SAF near Parkfield, California. Heat flow from the basement section of the borehole (770 to 2160 m) is 91 mW m-2, higher than the published 74 mW m -2 average for the Parkfield area. Within the resolution of the measurements, heat flow is constant across faults that intersect the borehole, suggesting that fluid flow does not alter the conductive thermal regime. Reanalysis of regional heat flow reveals an increase in heat flow along the SAF northwest of Parkfield. This transition corresponds to a shallowing base of seismicity and a change in fault behavior near the northern terminus of the M6 1966 Parkfield earthquake rupture. The persistence of elevated heat flow in the Coast Ranges to the west appears to rule out frictional heating on the SAF as the source of the SAFOD value.

Geophysical Research Letters↗

Geologic, water-chemistry, and hydrologic data from multiple-well monitoring sites and selected water-supply wells in the Santa Clara Valley, California, 1999-2003

To better identify the three-dimensional geohydrologic framework of the Santa Clara Valley, lithologic, geologic, geophysical, geomechanical, hydraulic, and water-chemistry data were collected from eight ground-water multiple-well monitoring sites constructed in Santa Clara County, California, as part of a series of cooperative studies between the U.S. Geological Survey and the Santa Clara Valley Water District. The data are being used to update and improve the three-dimensional geohydrologic framework of the basin and to address issues related to water supply, water chemistry, sequence stratigraphy, geology, and geological hazards. This report represents a compilation of data collected from 1999 to 2003, including location and design of the monitoring sites, cone penetrometer borings, geologic logs, lithologic logs, geophysical logs, core analysis, water-chemistry analysis, ground-water-level measurements, and hydraulic and geomechanical properties from wells and core samples. Exploratory cone penetrometer borings taken in the upper 17 to 130 feet at six of the monitoring sites identified the base of Holocene as no deeper than 75 feet in the central confined area and no deeper than 35 feet in the southern unconfined areas of the valley. Generalized lithologic characterization from the monitoring sites indicates about four to six different aquifer units separated by relatively fine-grained units occur within the alluvial deposits shallower than 860 feet deep. Analysis of geophysical logs indicates that coarse-grained units varied in thickness between 10 and 25 feet in the southeastern unconfined area of the valley and between 50 and 200 feet in the south-central and southwestern areas of the valley. Deviations from temperature-gradient logs indicate that the majority of horizontal ground-water flow occurs above a depth of 775 feet in the south central and above 510 feet in the southeastern areas of the valley. Bulk physical properties from more than 1,150 feet of core samples indicate an average primary-wave velocity of about 5,515 feet per second, a bimodal distribution of density between 2.19 and 2.32 grams per cubic centimeter with an average of 2.16 grams per cubic centimeter, and a magnetic susceptibility that generally ranged between 9 and 40 with an average of 22. Water-chemistry data indicate that the ground water in the alluvial aquifers generally is low in total dissolved solids and chloride and of good quality. Isotopic data indicate that water from artificial recharge is present throughout the shallower parts of the aquifer system but may not be present toward the center of the valley. The percentage of water from artificial recharge present in ground water ranges from 0 to 61 percent for water-supply wells. The age of most shallow ground water is less than 2,000 years before present, and the age of deeper ground water is as much as 39,900 years before present, as determined from carbon age dates. Initial water-level data from the multiple-well monitoring sites indicate seasonal water-level fluctuations as great as 60 feet and water-level differences between aquifers as great as 10 feet. The water-level hydrographs indicate different water-level changes and relations between aquifers in different parts of the basin. However, most of these hydrographs indicate the potential for downward water-level gradients, with lower hydraulic heads in the deeper monitoring wells. Hydraulic properties of selected new monitoring wells indicate that horizontal hydraulic conductivities range from 0.1 to 583 feet per day. Hydraulic testing of selected core samples yielded vertical hydraulic conductivity values ranging from 8 x 10-4 to 0.3 feet per day, and effective porosity values ranging from 0.21 to 0.4. Geomechanical properties estimated from one-dimensional consolidation tests of selected core samples resulted in geometric mean inelastic and elastic specific storage values of 1.5 x 10-

Scientific Investigations Report↗

Geothermal resources of California sedimentary basins

The 2004 Department of Energy (DOE) Strategic Plan for geothermal energy calls for expanding the geothermal resource base of the United States to 40,000 MW of electric power generating potential. This will require advances in technologies for exploiting unconventional geothermal resources, including Enhanced Geothermal Systems (EGS) and geopressured geothermal. An investigation of thermal conditions in California sedimentary basins through new temperature and heat flow measurements reveals significant geothermal potential in some areas. In many of the basins, the combined cooling effects of recent tectonic and sedimentary processes result in relatively low (<60 mW/m2) heat flow and geothermal gradients. For example, temperatures in the upper 3 km of San Joaquin, Sacramento and Ventura basins are typically less than 125??C and do not reach 200??c by 5 km. By contrast, in the Cuyama, Santa Maria and western Los Angeles basins, heat flow exceeds 80 mW/m2 and temperatures near or above 200??C occur at 4 to 5 km depth, which represents thermal conditions equivalent to or hotter than those encountered at the Soultz EGS geothermal site in Europe. Although the extractable geothermal energy contained in these basins is not large relative to the major California producing geothermal fields at The Geysers or Salton Sea, the collocation in the Los Angeles basin of a substantial petroleum extraction infrastructure and a major metropolitan area may make it attractive for eventual geothermal development as EGS technology matures.

Conference Paper↗

Santa Clara Valley water district multi-aquifer monitoring-well site, Coyote Creek Outdoor Classroom, San Jose, California

The U.S. Geological Survey (USGS), in cooperation with the Santa Clara Valley Water District (SCVWD), has completed the first of several multiple-aquifer monitoring-well sites in the Santa Clara Valley. This site monitors ground-water levels and chemistry in the one of the major historic subsidence regions south of San Jose, California, at the Coyote Creek Outdoor Classroom (CCOC) (fig. 1) and provides additional basic information about the geology, hydrology, geochemistry, and subsidence potential of the upper- and lower-aquifer systems that is a major source of public water supply in the Santa Clara Valley. The site also serves as a science education exhibit at the outdoor classroom operated by SCVWD.

Open-File Report↗

Characterization of rock thermal conductivity by high-resolution optical scanning

We compared thress laboratory methods for thermal conductivity measurements: divided-bar, line-source and optical scanning. These methods are widely used in geothermal and petrophysical studies, particularly as applied to research on cores from deep scientific boreholes. The relatively new optical scanning method has recently been perfected and applied to geophysical problems. A comparison among these methods for determining the thermal conductivity tensor for anisotropic rocks is based on a representative collection of 80 crystalline rock samples from the KTB continental deep borehole (Germany). Despite substantial thermal inhomogeneity of rock thermal conductivity (up to 40-50% variation) and high anisotropy (with ratios of principal values attaining 2 and more), the results of measurements agree very well among the different methods. The discrepancy for measurements along the foliation is negligible (<1%). The component of thermal conductivity normal to the foliation reveals somewhat larger differences (3-4%). Optical scanning allowed us to characterize the thermal inhomogeneity of rocks and to identify a three-dimensional anisotropy in thermal conductivity of some gneiss samples. The merits of optical scanning include minor random errors (1.6%), the ability to record the variation of thermal conductivity along the sample, the ability to sample deeply using a slow scanning rate, freedom from constraints for sample size and shape, and quality of mechanical treatment of the sample surface, a contactless mode of measurement, high speed of operation, and the ability to measure on a cylindrical sample surface. More traditional methods remain superior for characterizing bulk conductivity at elevated temperature.Three laboratory methods including divided-bar, line-source and optical scanning are widely applied in geothermal and petrophysical studies. In this study, these three methods were compared for determining the thermal conductivity tensor for anisotropic rocks. For this study, a representative collection of 80 crystalline rock samples from the KTB continental deep borehole was used. Despite substantial thermal inhomogeneity of rock thermal conductivity and high anisotropy, measurement results were in excellent agreement among the three methods.

Geothermics↗

Thermal regime of the San Andreas fault near Parkfield, California

Knowledge of the temperature variation with depth near the San Andreas fault is vital to understanding the physical processes that occur within the fault zone during earthquakes and creep events. Parkfield is near the southern end of the Coast Ranges segment of the San Andreas fault. This segment has higher mean heat flow than the Cape Mendocino segment to the northwest or the Mojave segment to the southeast. Boreholes were drilled specifically for the U.S. Geological Survey's Parkfield earthquake prediction experiment or converted from other uses at 25 sites within a few kilometers of the fault near Parkfield. These holes, which range in depth from 150 to over 1500m, were intended mainly for the deployment of volumetric strain meters, water-level recorders, and other downhole instruments. Temperature profiles were obtained from all the holes, and heat flow values were estimated from 17 of them. For a number of reasons, including a paucity of thermal conductivity data and rugged local topography, the accuracy of individual determinations was not sufficiently high to document local variations in heat flow. Values range from 54 to 92 mW m −2 , with mean and 95% confidence limits of 74±4 mW m −2 . This mean is slightly lower than the mean (83±3) of 39 previously published values from the central Coast Ranges, but it is consistent with the overall pattern of elevated heat flow in the Coast Ranges, and it is transitional to the mean of 68±2 mW m −2 that characterizes the Mojave segment of the San Andreas fault immediately to the south. The lack of a heat flow peak near the fault underscores the absence of a frictional thermal anomaly and provides additional support for a very small resolved shear stress parallel to the San Andreas fault and the nearly fault-normal maximum compressive stress observed in this region. Estimates of subsurface thermal conditions indicate that the seismicaseismic transition for the Parkfield segment corresponds to temperatures in the range of 350°–400°C. Increasing heat flow to the northwest of Parkfield corresponds to a transition from locked to creeping sections and to a shallowing of the base of seismicity and confirms the importance of temperature in controlling the thickness of the seismogenic crust. Lateral variations in heat flow do not appear to have any major role in determining the regularity of M 5.5–6 earthquakes at Parkfield.

Journal of Geophysical Research B: Solid Earth↗

Thermal conductivity of water-saturated rocks from the KTB pilot hole at temperatures of 25 to 300°C

The conductivitites of selected gneiss (two) and amphibolite (one) core samples have been measured under conditions of elevated temperature and pressure with a needle‐probe. Water‐saturated thermal conductivity measurements spanning temperatures from 25 to 300°C and hydrostatic pressures of 0.1 and 34 MPa confirm the general decrease in conductivity with increasing temperature but deviate significantly from results reported from measurements on dry samples over the same temperature range. The thermal conductivity of water‐saturated amphibolite decreases with temperature at a rate approximately 40% less than the rate for dry amphibolite, and the conductivity of water‐saturated gneiss decreases at a rate approximately 20% less than the rate for dry gneiss. The available evidence points to thermal cracking as the primary cause of the more rapid decrease in dry thermal conductivity with temperature. The effects of thermal cracking were also observed in the water‐saturated samples but resulted in a net decrease in room‐temperature conductivity of less than 3%. These results highlight the importance of duplicating in‐situ conditions when determining thermal conductivity for the deep crust.

Geophysical Research Letters↗

Temperature and the seismic/aseismic transition: Observations from the 1992 Landers earthquake

An important constraint on the size and destructive potential of earthquakes is the depth extent of rupture. Laboratory studies of the transition from unstable to stable sliding, along with ob served relationships between surface heat flow and the thickness of the seismogenic crust, provide strong evidence for the significance of temperature in determining the maximum nucleation depth of large earthquakes. The June 28, 1992, Mw 7.3 Landers earthquake ruptured fault segments within 20 km of 11 pre-existing heat flow measurements, and shallowing of the base of aftershock seismicity along strike correlates with an increase in heat flow. Crustal geotherms estimated from these measurements place the base of seismicity along the 250??C isotherm. This temperature is consistent with predictions from laboratory studies of the factional stability of Westerly granite, but estimated temperatures for the seismic-aseismic transition along other faults within the San Andreas fault system are in the range of 350 to 400??C. Variations in country rock and fault gouge composition, together with higher slip rates, may account for this difference, although part of the Landers seismogenic crust might remain unruptured. Copyright 1996 by the American Geophysical Union.

Geophysical Research Letters↗