USGS ScienceSearch

Geology topics

C. Lemieux

Publications and source records attributed to C. Lemieux.

2 recordsLinked to original sources

The effect of membrane filtration on dissolved trace element concentrations

The almost universally accepted operational definition for dissolved constituents is based on processing The almost universally accepted operational definition for dissolved constituents is based on processing whole-water samples through a 0.45-μm membrane filter. Results from field and laboratory experiments indicate that a number of factors associated with filtration, other than just pore size (e.g., diameter, manufacturer, volume of sample processed, amount of suspended sediment in the sample), can produce substantial variations in the ‘disolved’ concentrations of such elements as Fe, Al, Cu, Zn, Pb, Co, and Ni. These variations result from the inclusion/exclusion of colloidally-associated trace elements. Thus, 'dissolved' concentrations quantitated by analyzing filtrates generated by processing whole-water through similar pore-sized membrane filters may not be equal/comparable. As such, simple filtration through a 0.45-μm membrane filter may no longer represent an acceptable operational definition for dissolved chemical constituents. This conclusion may have important implications for environmental studies and regulatory agencies.

Water, Air, & Soil Pollution

The effect of using different 0.45 μm filter membranes on 'dissolved' element concentrations in natural waters

The effect of 4 different 0.45 μm pore size filter membrane systems on the ‘dissolved’ concentration of 28 elements in 5 natural water samples of varying matrix is reported. In 3 of the 5 waters, consistently higher concentrations of most elements (minor and trace) are obtained using Nucleopore 47 mm filter and the cellulose acetate/nitrate 47 mm filter than those measured using the 142 mm cellulose nitrate MFS filter or the Gelman capsule 47 mm filter. These distinct and coherent patterns in elemental behaviour disappear for the other 2 samples, an organic-rich peat water of high suspended load and a mineralised sample high in Si and Ca. Thus the nature and degree of filtration artifacts is matrix-dependent. These trends are evident in both data sets produced by 2 independent laboratories using different instrumentation, techniques and calibrating procedures. The average relative standard deviation in elemental concentration across the 4 filter types is in the range 9–21%. The presence of such filtration artifacts must be considered in projects where, for example, seasonal variability of water composition is under examination, data from various sources are being merged or hydrogeochemical surveys are being conducted.

Applied Geochemistry