USGS Science⌕ Search

Geology topics

C. Escobar

Publications and source records attributed to C. Escobar.

3 recordsLinked to original sources

Pre-exploitation state of the Ahuachapán geothermal field, El Salvador

The lithology and structural features of the Ahuachapán geothermal area and their impact on the movement of cold and hot fluids within the system are described, as well as the development and evaluation of the natural state model of the field. Four major lithologic units are present in Ahuachapán and three major aquifers have been identified; flow patterns and zones of fluid mixing were located on the basis of temperature and geochemical data from wells and surface manifestations. Geologic structures control the heat and fluid recharge and the flow within the reservoir. Modeling studies suggest, in agreement with field data, an overall average transmissivity of 25–35 darcy-meters, and indicate that the system is recharged by waters with temperatures greater than 250°C. The total thermal throughflow for the Ahuachapán reservoir in the unexploited state is estimated to be about 250 MW t .

Geothermics↗

Changes in thermodynamic conditions of the Ahuachapán reservoir due to production and injection

Since large-scale exploitation of the Ahuachapán reservoir began in 1975 large changes in the reservoir thermodynamic conditions have occurred. Drawdown of up to 15 bars and significant temperature changes have been observed in the wellfield. Temperatures have declined due to boiling in the reservoir in response to the pressure drawdown; localized and minor cooling due to reinjection of spent geothermal fluids have also been observed. There are indications of cold fluid influx deep into the reservoir from the west and north. Reservoir temperatures show that a significant amount of hot fluid recharge comes to the wellfield from the southeast, and temperatures also indicate that the recharge rate has increased with time as pressure declines in the reservoir. Chemical analyses of the produced fluids show that most wells are fed by a mixture of geothermal fluids and cooler, less-saline waters. The cold water inflow has increased due to exploitation, as demonstrated by decreased salinity of the produced fluids.

Geothermics↗

Geology of the platanares geothermal area, Departamento de Copan, Honduras

Platanares is located 16 km west of Santa Rosa de Copan, Honduras, along the Quebrada del Agua Caliente. The thermal manifestations are along faults in tuffs, tuffaceous sedimentary rocks, and lavas of the Padre Miguel Group. These tuffs are silicified near the faults, are fractured, and may provide the fracture permeability necessary for the hydrothermal system. Tuffs are overlain by a wedge of terrace gravels up to 60 m thick. Quaternary conglomerates of the Quebrada del Agua Caliente are cemented by silica sinter. The Platanares area contains numerous faults, all of which appear to be extensional. There are four groups of faults (N80/sup 0/E to N70/sup 0/W, N30/sup 0/ to 60/sup 0/W, N40/sup 0/ to 65/sup 0/E, and N00/sup 0/ to 05/sup 0/W). All hot springs at this site are located along faults that trend mostly northwest and north. Twenty-eight spring groups were described over an area of 0.2 km/sup 2/; half were boiling. Based on surface temperatures and flow rates, between 0.7 and 1.0 MW thermal energy is estimated for the area. The increased temperature of the stream flowing through the thermal area indicates that several megawatts of thermal energy are being added to the stream. We recommend that a dipole-dipole resistivity line be run along the Quebrada del Agua Caliente to identify zones of fracture permeability associated with buried faults and hot water reservoirs within those fault zones. A thermal gradient corehole should be drilled at Platanares to test temperatures, lithologies, and permeability of the hydrothermal system.

Journal of Volcanology and Geothermal Research↗