USGS ScienceSearch

Geology topics

B.J. Watten

Publications and source records attributed to B.J. Watten.

13 recordsLinked to original sources

Comparative performance of CO 2 measuring methods: marine aquaculture recirculation system application

Many methods are available for the measurement of dissolved carbon dioxide in an aqueous environment. Standard titration is the typical field method for measuring dissolved CO 2 in aquaculture systems. However, titrimetric determination of dissolved CO 2 in marine water aquaculture systems is unsuitable because of the high dissolved solids, silicates, and other dissolved minerals that interfere with the determination. Other methods used to measure dissolved carbon dioxide in an aquaculture water included use of a wetted CO 2 probe analyzer, standard nomographic methods, and calculation by direct measurements of the water's pH, temperature, and alkalinity. The determination of dissolved CO 2 in saltwater based on partial pressure measurements and non-dispersive infra-red (NDIR) techniques with a CO 2 gas analyzer are widely employed for oceanic surveys of surface ocean CO 2 flux and are similar to the techniques employed with the head space unit (HSU) in this study. Dissolved carbon dioxide (DC) determination with the HSU using a infra-red gas analyzer (IRGA) was compared with titrimetric, nomographic, calculated, and probe measurements of CO 2 in freshwater and in saltwater with a salinity ranging from 5.0 to 30 ppt, and a CO 2 range from 8 to 50 mg/L. Differences in CO 2 measurements between duplicate HSUs (0.1–0.2 mg/L) were not statistically significant different. The coefficient of variation for the HSU readings averaged 1.85% which was better than the CO 2 probe (4.09%) and that for the titrimetric method (5.84%). In all low, medium and high salinity level trials HSU precision was good, averaging 3.39%. Differences existed between comparison testing of the CO 2 probe and HSU measurements with the CO 2 probe readings, on average, providing DC estimates that were higher than HSU estimates. Differences between HSU and titration based estimates of DC increased with salinity and reached a maximum at 32.2 ppt. These differences were statistically significant (P < 0.05) at all salinity levels greater than 0.3 ppt. Results indicated reliable replicated results from the head space unit with varying salinity and dissolved carbon dioxide concentrations.

Aquacultural Engineering

Design procedure for hooded surface oxygen absorption systems

A design procedure addressing effluent total dissolved gas pressure limits along with standard performance indicators such as oxygen absorption efficiency (kg absorbed/kg applied), and transfer efficiency (kg/kW.h), is presented for surface agitation equipment operating in an oxygen-enriched atmosphere. Application of this contactor type in closed culture systems is attractive given its insensitivity to biological fouling and ability to operate without the need for a significant hydraulic gradient. Performance algorithms were developed through application of chemical reactor theory, Henry's Law and the Ideal Gas Law. In the analysis, gas and liquid phases were treated as being homogeneous. The design steps presented are unique in that required mass transfer coefficients (K L a), operating pressures (CP), and oxygen feed rates (G/L) are calculated for target changes in both dissolved oxygen and nitrogen without the use of iterative numerical procedures. A second calculation sequence establishes the sensitivity of system performance to changes in G/L when CP and K L a are known.

Journal of the World Aquaculture Society

Continuous monitoring of dissolved oxygen and total dissolved gas pressure based on head-space partial pressures

We describe an instrument prototype that measures total dissolved gas pressure (TGP) and dissolved oxygen (DO) without need for standard wetted probe membranes or gas permeable tubing. Measurements were based instead on gas-phase partial pressures that develop within the head-space of a pressure vessel, and on Henry's Law. Performance trials established that differences between standard instrumentation and test instrument OP readings average -1.6-mm Hg (SD = 2.19, range -4.8 to -5.3) within the ΔP range of -72 to 123-mm Hg. Additional trials demonstrated the ability of the instrument to closely follow positive and negative changes in TGP at rates approaching 30-mm Hg/h. Here, the difference between test and standard instrumentation derived TGP averaged 3.4-mm Hg (range 0–41). Differences in ΔP measured by test instrument and gasometer increased with water throughput; mean differences were -3.9, -4.3, and -6.0 for water throughput of 4.6, 6.7, and 7.8 L/min, respectively. However, time to reach 90% of the steady-state instrument reading was highest for low water throughput; equilibrium times averaged 90.9, 44.4, and 44.7 min for water throughput of 4.6, 6.7, 7.8 L/min, respectively. Differences between titration and test-instrumentation based DO measurements were acceptable, averaging -0.11 mg/L (SD = 0.41, range -0.85 to 0.85) over DO from 3.3 to 19.2 mg/L and for 11.1 and 24.2 C. Whereas test instrument DO readings were indistinguishable from Winkler titration at 24.2 C; at 11.1 C there was a tendency for test instrument readings to be lower than Winkler titration at DO < 14 mg/L and higher at DO > 14 mg/L. Trials conducted under biological fouling conditions demonstrated the test instrument's ability to operate with 30% of the maintenance required by standard instrumentation.

Journal of the World Aquaculture Society

Comparative performance of fixed-film biological filters: Application of reactor theory

Nitrification is classified as a two-step consecutive reaction where R1 represents the rate of formation of the intermediate product NO2-N and R2 represents the rate of formation of the final product NO3-N. The relative rates of R1 and R2 are influenced by reactor type characterized hydraulically as plug-flow, plug-flow with dispersion and mixed-flow. We develop substrate conversion models for fixed-film biofilters operating in the first-order kinetic regime based on application of chemical reactor theory. Reactor type, inlet conditions and the biofilm kinetic constants Ki (h-1) are used to predict changes in NH4-N, NO2-N, NO3-N and BOD5. The inhibiting effects of the latter on R1 and R2 were established based on the ?? relation, e.g.:{A formula is presented}where BOD5,max is the concentration that causes nitrification to cease and N is a variable relating Ki to increasing BOD5. Conversion models were incorporated in spreadsheet programs that provided steady-state concentrations of nitrogen and BOD5 at several points in a recirculating aquaculture system operating with input values for fish feed rate, reactor volume, microscreen performance, make-up and recirculating flow rates. When rate constants are standardized, spreadsheet use demonstrates plug-flow reactors provide higher rates of R1 and R2 than mixed-flow reactors thereby reducing volume requirements for target concentrations of NH4-N and NO2-N. The benefit provided by the plug-flow reactor varies with hydraulic residence time t as well as the effective vessel dispersion number, D/??L. Both reactor types are capable of providing net increases in NO2-N during treatment but the rate of decrease in the mixed-flow case falls well behind that predicted for plug-flow operation. We show the potential for a positive net change in NO2-N increases with decreases in the dimensionless ratios K2, (R2 )/K1,( R1 ) and [NO2-N]/[NH4-N] and when the product K1, (R1) t provides low to moderate NH4-N conversions. Maintaining high levels of the latter reduces the effective reactor utilization rate (%) defined here as (RNavg/RNmax)100 where RNavg is the mean reactive nitrogen concentration ([NH4-N] + [NO2-N]) within the reactor, and RNmax represents the feed concentration of the same. Low utilization rates provide a hedge against unexpected increases in substrate loading and reduce water pumping requirements but force use of elevated reactor volumes. Further ?? effects on R1 and R2 can be reduced through use of a tanks-in-series versus a single mixed-flow reactor configuration and by improving the solids removal efficiency of microscreen treatment.

Aquacultural Engineering

Limestone fluidized bed treatment of acid-impacted water at the Craig Brook National Fish Hatchery, Maine, USA

Decades of atmospheric acid deposition have resulted in widespread lake and river acidification in the northeastern U.S. Biological effects of acidification include increased mortality of sensitive aquatic species such as the endangered Atlantic salmon (Salmo salar). The purpose of this paper is to describe the development of a limestone-based fluidized bed system for the treatment of acid-impacted waters. The treatment system was tested at the Craig Brook National Fish Hatchery in East Orland, Maine over a period of 3 years. The product water from the treatment system was diluted with hatchery water to prepare water supplies with three different levels of alkalinity for testing of fish health and survival. Based on positive results from a prototype system used in the first year of the study, a larger demonstration system was used in the second and third years with the objective of decreasing operating costs. Carbon dioxide was used to accelerate limestone dissolution, and was the major factor in system performance, as evidenced by the model result: Alk = 72.84 ?? P(CO2)1/2; R2 = 0.975. No significant acidic incursions were noted for the control water over the course of the study. Had these incursions occurred, survivability in the untreated water would likely have been much more severely impacted. Treated water consistently provided elevated alkalinity and pH above that of the hatchery source water. ?? 2005 Elsevier B.V. All rights reserved.

Aquacultural Engineering

Acid neutralization within limestone sand reactors receiving coal mine drainage

Pulsed bed treatment of acid mine drainage (AMD) uses CO2 to accelerate limestone dissolution and intermittent fluidization to abrade and carry away metal hydrolysis products. Tests conducted with a prototype of 60 L/min capacity showed effective removal of H+ acidity over the range 196-584 mg/L (CaCO3) while concurrently generating surplus acid neutralization capacity. Effluent alkalinity (mg/L CaCO3) rose with increases in CO2 (DC, mg/L) according to the model Alkalinity = 31.22 + 2.97(DC)0.5, where DC was varied from 11-726 mg/L. Altering fluidization and contraction periods from 30 s/30 s to 10 s/50 s did not influence alkalinity but did increase energy dissipation and bed expansion ratios. Field trials with three AMD sources demonstrated the process is capable of raising AMD pH above that required for hydrolysis and precipitation of Fe3+ and Al3+ but not Fe2+ and Mn2+. Numerical modeling showed CO2 requirements are reduced as AMD acidity increases and when DC is recycled from system effluent. ?? 2005 Elsevier Ltd. All rights reserved.

Environmental Pollution

Feasibility of measuring dissolved carbon dioxide based on head space partial pressures

We describe an instrument prototype that measures dissolved carbon dioxide (DC) without need for standard wetted probe membranes or titration. DC is calculated using Henry's Law, water temperature, and the steady-state partial pressure of carbon dioxide that develops within the instrument's vertical gas-liquid contacting chamber. Gas-phase partial pressures were determined with either an infrared detector (ID) or by measuring voltage developed by a pH electrode immersed in an isolated sodium carbonate solution (SC) sparged with recirculated head space gas. Calculated DC concentrations were compared with those obtained by titration over a range of DC (2, 4, 8, 12, 16, 20, 24, and 28mg/l), total alkalinity (35, 120, and 250mg/l as CaCO3), total dissolved gas pressure (-178 to 120 mmHg), and dissolved oxygen concentrations (7, 14, and 18 mg/l). Statistically significant (P < 0.001) correlations were established between head space (ID) and titrimetrically determined DC concentrations (R2 = 0.987-0.999, N = 96). Millivolt and titrimetric values from the SC solution tests were also correlated (P < 0.001, R 2 = 0.997, N = 16). The absolute and relative error associated with the use of the ID and SC solution averaged 0.9mg/l DC and 7.0% and 0.6 mg/l DC and 9.6%, respectively. The precision of DC estimates established in a second test series was good; coefficients of variation (100(SD/mean)) for the head space (ID) and titration analyses were 0.99% and 1.7%. Precision of the SC solution method was 1.3%. In a third test series, a single ID was coupled with four replicate head space units so as to permit sequential monitoring (15 min intervals) of a common water source. Here, appropriate gas samples were secured using a series of solenoid valves (1.6 mm bore) activated by a time-based controller. This system configuration reduced the capital cost per sample site from US$ 2695 to 876. Absolute error averaged 2.9, 3.1, 3.7, and 2.7 mg/ l for replicates 1-4 (N = 36) during a 21-day test period (DC range, 36-40 mg/l). The ID meter was then modified so as to provide for DO as well as DC measurements across components of an intensive fish production system. ?? 2003 Elsevier B.V. All rights reserved.

Aquacultural Engineering

Factors influencing the nitrification efficiency of fluidized bed filter with a plastic bead medium

The performance of fluidized bed nitrification filters charged with 2 ?? 4 ABS plastic beads (specific gravity 1.06) was evaluated. Three unique bed-height to diameter ratios were established, in triplicate, using column diameters of 12.7, 15.2 and 17.8 cm. Filters received water spiked with recycled nutrients and ammonia (TAN), from one of the three 500 1 feed tank system. With daily ammonia loading fixed at 8.6 g per system, TAN removal increased with column diameter at each of four tests hydraulic loading rates (6, 8, 10 and 12 Lpm). TAN in recirculated water (influent) rose from 0.5 to 1.0 mg/1 as ammonia loading increased from 180 mg/m2-day to 360 mg/m2-day. When hydraulic loading was fixed at 12 Lpm, TAN removal (%) was maximized with ammonia loadings ranging from 225 to 270 mg/m2-day. Biofilm thickness increased with ammonia loading, but decreased with increased hydraulic loading rates. Fluidized beds of ABS plastic beads were effective in reducing energy costs (head loss) of water treatment. ?? 2002 Elsevier Science B.V. All rights reserved.

Aquacultural Engineering

Hydraulic characteristics of a rectangular mixed-cell rearing unit

We describe a fish rearing unit modification that establishes mixed flow reactor (MFR) behavior in a rectangular vessel so as to eliminate metabolite concentration gradients, increase current velocities and improve solids scour at low water exchange rates. A standard raceway section 14.5 m long was modified to create six counter-rotating mixed cells, each 2.4 m wide by 2.4 m long. Cells receive water from vertical pipe sections extending to the tank floor and positioned in the corners of the cells. Vertical pipe sections were fabricated with jet ports that direct water into the cells tangentially to establish rotary circulation. Water exits each cell through a centrally located floor drain. Hydraulic characteristics of the tank are described based on an analysis of residence time distribution, current velocities and cell-to-cell water exchange rates. The latter was calculated based on a proposed hydraulics model and tracer concentrations established at a steady state. Vessel dispersion numbers measured with water exchange rates of 1.0 and 1.3 per hour, indicate tank performance approximates that of a MFR with the active tank volume representing 77.9–100% of total tank volume. Water velocities measured at 216 stations averaged 0.14, 0.12 and 0.12 m/s for the tank surface, mid-depth and near bottom regions. The benthic shear stress calculated given surface velocity was 0.04 N/m 2 . This was sufficient to scour and purge fecal solids produced by 2010 kg of lake trout that averaged 44.3 cm in total length. Cell interaction was significant with cell-to-cell exchange rates averaging 3.9 times the tank inflow rate. Energy requirements of the rearing unit were kept low (1.32 m water gauge pressure; 6.7 W/m 3 ) through use of a large number of low velocity jets.

Aquacultural Engineering