Determining the distribution of hydraulic conductivity in a fractured limestone aquifer by simultaneous injection and geophysical logging

A field technique for assessing the vertical distribution of hydraulic conductivity in an aquifer was applied to a fractured carbonate formation in southeastern Nevada. The technique combines the simultaneous use of fluid injection and geophysical logging to measure in situ vertical distributions of fluid velocity and hydraulic head down the borehole; these data subsequently are analyzed to arrive at quantitative estimates of hydraulic conductivity across discrete intervals in the aquifer. The results of this analysis identified the contact margin between the Anchor and Dawn Members of the Monte Cristo Limestone as being the dominant transmissive unit. -from Authors

Nevada

Design, operation, and data analysis for a wireline packer system in open boreholes, with field-test results from Belvidere, Illinois

A wireline-operated packer was designed for use with a standard geophysical logging system. The packer probe consists of a downhole packer inflated with water removed from the borehole by an in-line submersible pump, and a differential pressure transducer calibrated to measure the hydraulic-head difference between the zones above and below the packer. Analysis of the packer data is based on a numerical model that predicts the water levels above and below the packer for a given set of aquifer zones of specified hydraulic head and transmissivity. Various computations are used to indicate the sensitivity of the packer measurements to the hydraulic head and transmissivity contrasts between aquifer zones. The wireline-packer probe was field tested in a series of open-bedrock boreholes in Belvidere, Illinois, at a site where vertical hydraulic-head differences are produced in a horizontally stratified aquifer by water production from an underlying aquifer. Analysis of the wireline-packer data produced estimates of hydraulic-head gradient and aquifer-zone transmissivity consistent with results from straddle-packer hydraulic tests. However, the wireline-packer data also indicated that there are significant variations of vertical hydraulic gradient with depth, and that the gradient is sharply reversed near the bottom of the boreholes. This result is consistent with upward ambient flow measured on previous occasions near the bottom of these boreholes, and has important consequences for the monitoring of ground-water flow at the study site.

Illinois

Geophysical well log analysis of fractured granitic rocks at Atikokan, Ontario, Canada

Two boreholes, drilled to approximate depths of 750 and 1,260 m in a granitic intrusion located near Atikokan, Ontario, were studied by obtaining a full suite of conventional borehole geophysical logs. In addition, selected intervals in these boreholes were logged with a borehole acoustic televiewer that produces a high-resolution image of the borehole wall, an acoustic waveform-logging system using 34-kiloHertz magnetostrictive and 5-kiloHertz sparker sources, and a highly sensitive heat-pulse flowmeter. Emphasis was on identifying and characterizing fracture zones that represent groundwater conduits in deeper portions of the granite, and on characterizing the properties of the largest intervals of unfractured granite. Major fracture zones were indicated by correlating geophysical log anomalies detected on the suite of conventional logs (unpublished data from Atomic Energy of Canada). However, several other anomalies, were identified as mafic intrusions of approximately the same thickness as major fracture zones. Geophysical log anomalies were compared for all major fracture zones that could serve as significant groundwater conduits, and fracture zone permeability is estimated on the basis of acoustic tube-wave attenuation in these intervals. Acoustic televiewer logs obtained at depths below 1,000 m in the deeper well indicate that most of the few fractures identified on core at these depths do not remain open enough under in situ conditions to produce detectable anomalies in acoustic refraction. Flowmeter data indicate that some groundwater circulation occurs in the upper portion of both boreholes. Water in the shallower of the two holes was observed to flow at 2.0 L/min; most of this flow entered the borehole at a depth < 25 m, and no flow occurred below a depth of 100 m. Downflow at rates < 0.5 L/min was determined to enter the deeper borehole within 20 m of the surface, and to exist at various fractures down to a depth of 250 m. (Author 's abstract)

Water-Resources Investigations Report

Geophysical well-log analysis of fractured crystalline rocks at East Bull Lake, Ontario, Canada

Various conventional geophysical borehole measurements were made in conjunction with measurements using a recently designed, low-frequency, acoustic-waveform probe and slow velocity flowmeter for characterization of a fractured mafic intrusion in southern Ontario, Canada. Conventional geophysical measurements included temperature, caliper, gamma, acoustic, single-point resistance, and acoustic televiewer logs. Hole stability problems prevented the use of neutron and gamma-gamma logs, because these logs require that a radioactive source be lowered into the borehole. Measurements were made in three boreholes as much as 850 m deep and penetrating a few tens of meters into granitic basement. All rocks within the mafic intrusion were characterized by minimal gamma radiation and acoustic velocities of about 6.9 km/sec. The uniformity of the acoustic velocities and the character of acoustic-waveform logs made with a conventional high-frequency logging source correlated with the density of fractures evident on televiewer logs. Sample intervals of high-frequency waveform logs were transformed into interpretations of effective fracture opening using a recent model for acoustic attenuation in fractured rocks. The new low-frequency sparker source did not perform as expected at depths below 250 m because of previously unsuspected problems with source firing under large hydrostatic heads. A new heat-pulse, slow velocity flowmeter was used to delineate in detail the flow regime indicated in a general way by temperature logs. The flowmeter measurements indicated that water was entering 2 of the boreholes at numerous fractures above a depth of 200 m, with flow in at least 2 of the boreholes exiting through large isolated fractures below a depth of 400 m. (Author 's abstract)

Water-Resources Investigations Report

EFFECTS OF LITHOLOGY ON TELEVIEWER-LOG QUALITY AND FRACTURE INTERPRETATION.

Representative televiewer logs illustrating natural fractures in such common rock types as granite, gabbro, basalt, schist, sandstone, limestone and shale are presented in addition to photographs of the same fractures in core samples. These examples demonstrate the many difficulties in recognizing fractures on televiewer logs compared to fractures in logs because of the vertical scale distortion on televiewer logs and from drilling damage to the fractures at the borehole wall. All of these results demonstrate that significant fracture widening usually occurs during drilling, explaining why fractures described by the core logger as closed can be consistently detected on televiewer logs.

Conference Paper

A heat-pulse flowmeter for measuring minimal discharge rates in boreholes

The U.S. Geological Survey has tested a borehole-configured heat-pulse flowmeter which has good low-velocity flow-measuring sensitivity. The flowmeter was tested in the laboratory in 51-, 102-, and 152-millimeter-diameter columns using water velocities ranging from 0.35 to 250 millimeters per second. The heat-pulse flowmeter also was tested in a 15-meter-deep granite test pit with controlled water flow, and in a 58-meter-deep borehole in sedimentary materials. The flowmeter's capability to detect and measure naturally occurring, low-velocity, thermally induced convection currents in boreholes was demonstrated. Further improvements to the heat-pulse-flowmeter system are needed to increase its reliability and improve its response through four-conductor logging cable.

Open-File Report